Development of a high-performance water-to-water heat pump for ground-source application

被引:0
|
作者
Shiba, Y. [1 ]
Ooka, R. [1 ]
Sekine, K. [1 ]
机构
[1] Zeneral Heatpump Ind Co Ltd, Dept Dev, Nagoya, Aichi, Japan
来源
ASHRAE TRANSACTIONS 2007 VOL 113, PT 2 | 2007年 / 113卷
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
A high-performance water-to-water heat pump for ground-source application was developed using a plate heat exchanger a new type of compressor and refrigerant cycle with a liquid-gas heat exchanger A performance design program used to compute the refrigerant cycle with a liquid-gas heat exchanger was created first. This simulation program could predict the heating/cooling capacity, electric power and COP. This determined the surface area of the heat exchangers, compressor efficiency and displacement, etc. Second, a real heat pump was designed based on the results of the program, then built and tested to compare its performance with the simulation. As a result, a value of 5.5 was attained both for the cooling COP of the designed heat pump via the simulation and the measured cooling COP of the real heat pump.
引用
收藏
页码:261 / 270
页数:10
相关论文
共 50 条
  • [1] A variable speed water-to-water heat pump model used for ground-source applications
    Viviescas, Geoffrey
    Bernier, Michel
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2024, 30 (03) : 266 - 279
  • [2] Performance Analysis of a Ground-Source Heat Pump System Using Mine Water as Heat Sink and Source
    Liu, Xiaobing
    Malhotra, Mini
    Walburger, Adam
    Skinner, Jack L.
    Blackketter, Donald M.
    ASHRAE TRANSACTIONS, VOL 122, PT 2, 2016, 122 : 160 - 172
  • [3] Simulation of a high temperature water-to-water heat pump
    Li, Ting-Xun
    Guo, Kai-Hua
    Wang, Ru-Zhu
    Fan, Shuan-Shi
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2002, 23 (05):
  • [4] APPLICATION OF THE GROUND-SOURCE HEAT PUMP SYSTEMS IN CHINA
    Yang, Wei
    Zhou, Jin
    Xu, Wei
    Zhang, Guoqiang
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 1836 - 1843
  • [5] Development of a Residential Ground-Source Integrated Heat Pump
    Rice, Keith
    Baxter, Van
    Hern, Shawn
    McDowell, Tim
    Munk, Jeffrey
    Shen, Bo
    2013 ASHRAE WINTER CONFERENCE, 2013,
  • [6] Modelling of a water-to-air variable capacity ground-source heat pump
    Bouheret, Samuel
    Bernier, Michel
    JOURNAL OF BUILDING PERFORMANCE SIMULATION, 2018, 11 (03) : 283 - 293
  • [7] PERFORMANCE-CHARACTERISTICS OF A HIGH-TEMPERATURE WATER-TO-WATER HEAT-PUMP
    PARISE, JAR
    CARTWRIGHT, WG
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1988, 12 (04) : 647 - 660
  • [8] Influence of reversing methods on the performance of a reversible water-to-water heat pump
    Rajapaksha, L
    Suen, KO
    APPLIED THERMAL ENGINEERING, 2003, 23 (01) : 49 - 64
  • [9] A study on the performance characteristics of a testing facility for a water-to-water heat pump
    Amoabeng, Kofi Owura
    Lee, Kwang Ho
    Choi, Jong Min
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 86 : 113 - 126
  • [10] Influence of the source and sink temperatures on the optimal refrigerant charge of a water-to-water heat pump
    Corberan, Jose-M.
    Martinez-Galvan, Israel
    Martinez-Ballester, Santiago
    Gonzalvez-Macia, Jose
    Royo-Pastor, Rafael
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (04): : 881 - 892