Correlation of radiation dose and activity with clinical outcomes in metastatic colorectal cancer after selective internal radiation therapy using yttrium-90 resin microspheres

被引:8
作者
Badiyan, Shahed [1 ]
Bhooshan, Neha [4 ]
Chuong, Michael D. [6 ]
Sharma, Navesh [1 ,5 ]
Akhter, Nabeel [2 ]
Etezadi, Vahid [2 ]
Hausner, Petr [3 ]
Kudryasheva, Svetlana [1 ]
Kaiser, Adeel [1 ]
Becker, Stewart [1 ]
Guerrero, Mariana [1 ]
Yi, Byong Y. [1 ]
机构
[1] Univ Maryland, Sch Med, Dept Radiat Oncol, Baltimore, MD 21201 USA
[2] Univ Maryland, Sch Med, Dept Diagnost Radiol & Nucl Med, Baltimore, MD 21201 USA
[3] Univ Maryland, Sch Med, Div Med Oncol, Baltimore, MD 21201 USA
[4] UPMC Pinnacle Hlth Radiat Oncol, Harrisburg, PA USA
[5] Milton S Hershey Med Ctr, Penn State Hlth, Dept Radiat Oncol, Hershey, PA USA
[6] Baptist Hlth South Florida, Miami Canc Inst, Miami, FL USA
关键词
colorectal cancer; dosimetry; liver metastases; radioembolization; selective internal radiation therapy; yttrium-90; microspheres; LIVER METASTASES; RADIOEMBOLIZATION; MALIGNANCIES; DOSIMETRY; BRACHYTHERAPY; CHEMOTHERAPY;
D O I
10.1097/MNM.0000000000000887
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeYttrium-90 (Y-90)-resin microspheres are prescribed using activity. We evaluated overall survival (OS) and radiographic tumor response after selective internal radiation therapy (SIRT) with resin microspheres in patients with liver metastases from colorectal cancer.Patients and methodsWe retrospectively reviewed 60 metastatic colorectal cancer patients treated at our institution with SIRT using Y-90-resin microspheres. Each patient underwent pre-SIRT MRI or computed tomography imaging of the liver with intravenous contrast. Patients underwent post-treatment imaging at 2-3-month intervals with response assessed according to unidimensional Response Evaluation Criteria in Solid Tumors (RECIST) criteria as well as published three-dimensional volumetric criteria. We then related the prescribed activity established by the body surface area method and the corresponding prescribed dose to radiographic treatment response and OS.ResultsThe median follow-up after the first SIRT treatment was 8.9 months. The mean prescribed activity and the prescribed dose were 26.6mCi and 52.8Gy, respectively. OS was not significantly associated with either prescribed activity or prescribed dose. Prescribed dose was also not related to response. However, a significant relationship was found between a higher prescribed activity and an improved radiographic response by RECIST (P=0.04) at the second follow-up.ConclusionThe prescribed activity of Y-90-resin microspheres may be correlated with radiographic response by RECIST criteria at 4-6 months post-treatment. For a more accurate prediction of response, a valid dose calculation model based on post-Y-90 PET dosimetry is likely needed given the heterogeneous dose delivery seen in SIRT.
引用
收藏
页码:915 / 920
页数:6
相关论文
共 27 条
[11]   Post-radioembolization yttrium-90 PET/CT - part 2: dose-response and tumor predictive dosimetry for resin microspheres [J].
Kao, Yung-Hsiang ;
Steinberg, Jeffrey D. ;
Tay, Young-Soon ;
Lim, Gabriel K. Y. ;
Yan, Jianhua ;
Townsend, David W. ;
Budgeon, Charley A. ;
Boucek, Jan A. ;
Francis, Roslyn J. ;
Cheo, Timothy S. T. ;
Burgmans, Mark C. ;
Irani, Farah G. ;
Lo, Richard H. G. ;
Tay, Kiang-Hiong ;
Tan, Bien-Soo ;
Chow, Pierce K. H. ;
Satchithanantham, Somanesan ;
Tan, Andrew E. H. ;
Ng, David C. E. ;
Goh, Anthony S. W. .
EJNMMI RESEARCH, 2013, 3 :1-27
[12]   Post-radioembolization yttrium-90 PET/CT - part 1: diagnostic reporting [J].
Kao, Yung-Hsiang ;
Steinberg, Jeffrey D. ;
Tay, Young-Soon ;
Lim, Gabriel K. Y. ;
Yan, Jianhua ;
Townsend, David W. ;
Takano, Angela ;
Burgmans, Mark C. ;
Irani, Farah G. ;
Teo, Terence K. B. ;
Yeow, Tow-Non ;
Gogna, Apoorva ;
Lo, Richard H. G. ;
Tay, Kiang-Hiong ;
Tan, Bien-Soo ;
Chow, Pierce K. H. ;
Satchithanantham, Somanesan ;
Tan, Andrew E. H. ;
Ng, David C. E. ;
Goh, Anthony S. W. .
EJNMMI RESEARCH, 2013, 3 :1-28
[13]   Resin 90Y-microsphere brachytherapy for unresectable colorectal liver metastases:: Modern USA experience [J].
Kennedy, Andrew S. ;
Coldwell, Douglas ;
Nutting, Charles ;
Murthy, Ravi ;
Wertman, Daniel E., Jr. ;
Loehr, Stephen P. ;
Overton, Carroll ;
Meranze, Steven ;
Niedzwiecki, Jerry ;
Sailer, Scott .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (02) :412-425
[14]   A population-based study of the incidence, management and prognosis of hepatic metastases from colorectal cancer [J].
Leporrier, J ;
Maurel, J ;
Chiche, L ;
Bara, S ;
Segol, P ;
Launoy, G .
BRITISH JOURNAL OF SURGERY, 2006, 93 (04) :465-474
[15]   RADIATION PNEUMONITIS AFTER SELECTIVE INTERNAL RADIATION TREATMENT WITH INTRAARTERIAL (90)YTTRIUM-MICROSPHERES FOR INOPERABLE HEPATIC-TUMORS [J].
LEUNG, TWT ;
LAU, WY ;
HO, SKW ;
WARD, SC ;
CHOW, JHS ;
CHAN, MSY ;
METREWELI, C ;
JOHNSON, PJ ;
LI, AKC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (04) :919-924
[16]   Feasibility of 90Y TOF PET-based dosimetry in liver metastasis therapy using SIR-Spheres [J].
Lhommel, Renaud ;
van Elmbt, Larry ;
Goffette, Pierre ;
Van den Eynde, Marc ;
Jamar, Francois ;
Pauwels, Stanislas ;
Walrand, Stephan .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (09) :1654-1662
[17]   Radiologic assessment of rectosigmoid cancer before and after neoadjuvant radiation therapy: Comparison between quantitation techniques [J].
Luccichenti, G ;
Cademartiri, F ;
Sianesi, M ;
Roncoroni, L ;
Pavone, P ;
Krestin, GP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (02) :526-530
[18]   Differences in 3D dose distributions due to calculation method of voxel S-values and the influence of image blurring in SPECT [J].
Pacilio, Massimiliano ;
Amato, Ernesto ;
Lanconelli, Nico ;
Basile, Chiara ;
Alberto Torres, Leonel ;
Botta, Francesca ;
Ferrari, Mahila ;
Cornejo Diaz, Nestor ;
Coca Perez, Marco ;
Fernandez, Maria ;
Lassmann, Michael ;
Vergara Gil, Alex ;
Cremonesi, Marta .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (05) :1945-1964
[19]   RADIATION-ASSOCIATED LIVER INJURY [J].
Pan, Charlie C. ;
Kavanagh, Brian D. ;
Dawson, Laura A. ;
Li, X. Allen ;
Das, Shiva K. ;
Miften, Moyed ;
Ten Haken, Randall K. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (03) :S94-S100
[20]   Radioembolization and the dynamic role of Y-90 PET/CT [J].
Pasciak, Alexander S. ;
Bourgeois, Austin C. ;
McKinney, J. Mark ;
Chang, Ted T. ;
Osborne, Dustin R. ;
Acuff, Shelley N. ;
Bradley, Yong C. .
FRONTIERS IN ONCOLOGY, 2014, 4