Anterior Chamber Angle and Trabecular Meshwork Measurements Made by Fourier-domain Optical Coherence Tomography in Healthy White Children

被引:12
作者
Fernandez-Vigo, Jose I. [1 ,3 ]
De-Pablo-Gomez-de-Liano, Lucia [3 ]
Fernandez-Vigo, Cristina [3 ]
Arcos-Villegas, Gabriel [1 ]
Fernandez-Perez, Cristina [2 ]
Garcia-Feijoo, Julian [1 ]
Fernandez-Vigo, Jose A. [3 ,4 ]
机构
[1] Hosp Univ Clin San Carlos, Inst Invest Sanitaria IdISSC, Dept Ophthalmol, Madrid, Spain
[2] Hosp Univ Clin San Carlos, Inst Invest Sanitaria IdISSC, Dept Prevent Med, Madrid, Spain
[3] Ctr Int Oftalmol Avanzada, Madrid, Spain
[4] Univ Extremadura, Dept Ophthalmol, Badajoz, Spain
关键词
anterior chamber angle; trabecular meshwork; optical coherence tomography; children; glaucoma; PRIMARY CONGENITAL GLAUCOMA; SEGMENT PARAMETERS; CHINESE; CAUCASIANS; WIDTH; DETERMINANTS; SINGAPOREANS; BIOMETRY; CLOSURE; LENGTH;
D O I
10.1097/IJG.0000000000000724
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To obtain anterior chamber angle and trabecular meshwork (TM) measurements by Fourier-domain optical coherence tomography (FD-OCT) in a population of healthy white children. Materials and Methods: This was a cross-sectional study examining 409 right eyes of 409 children. Trabecular-iris angle (TIA) and TM length and area were measured by FD-OCT (RTVue 100) in the nasal and temporal quadrants to analyze correlations between angle or TM measurements and age, sex, and refractive error. Results: Mean participant age was 10.5 +/- 3.4 years (range, 3 to 18 y); 51% were boys. Mean spherical error was 0.56 +/- 2.4D (range, - 9 to + 7.5 D). TIA could be measured in 99%, whereas TM measurements could only be made in 83%. Mean TIA was 43.1 +/- 10.0 degrees (range, 16 to 76 degrees). No differences were observed in angle width according to sex (P=0.299; t test). TIA was correlated with age (R=0.204; P< 0.001) and with spherical error (R= - 0.457; P< 0.001). Mean TM length was 530 +/- 106 mm (range, 299 to 891 mm) and mean TM area was 0.065 +/- 0.021mm2 (range, 0.030 to 0.180mm(2)). No correlation was observed between TM metrics and age, sex or refractive error (R< 0.08; P >= 0.172). Conclusions: FD-OCT proved useful for the noninvasive measurement of TIA and TM metrics in children. Spherical error was the main determinant of TIA.
引用
收藏
页码:810 / 815
页数:6
相关论文
共 28 条
[1]   Differences of the Anterior Segment Parameters in Children with Down Syndrome [J].
Aslan, Lokman ;
Aslankurt, Murat ;
Aksoy, Adnan ;
Gumusalan, Yakup .
OPHTHALMIC GENETICS, 2014, 35 (02) :74-78
[2]   Application of Anterior Segment Optical Coherence Tomography in Pediatric Ophthalmology [J].
Cauduro, Ricardo Salles ;
Ferraz, Caroline do Amaral ;
Avila Morales, Maira Saad ;
Garcia, Patricia Novita ;
Lopes, Yara Cristina ;
Souza, Paulo Henrique ;
Allemann, Norma .
JOURNAL OF OPHTHALMOLOGY, 2012, 2012
[3]   Comparison of iridocorneal angle in infants with retinopathy of prematurity and healthy infants using spectral domain optical coherence tomography [J].
Cernichiaro-Espinosa, Linda A. ;
Garcia-Huerta, Maria M. ;
Giordano, Veronica E. ;
Salinas-Longoria, Samantha M. ;
Romero-Vera, Rafael ;
Garcia-Aguirre, Gerardo ;
Martinez-Castellanos, Maria A. .
JOURNAL OF AAPOS, 2014, 18 (04) :344-346
[4]   Novel anterior-chamber angle measurements by high-definition optical coherence tomography using the Schwalbe line as the landmark [J].
Cheung, Carol Y. ;
Zheng, Ce ;
Ho, Ching-Lin ;
Tun, Tin A. ;
Kumar, Rajesh S. ;
El Sayyad, Fouad ;
Wong, Tien Y. ;
Aung, Tin .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (07) :955-959
[5]   Assessment of anterior chamber angle using Visante OCT, slit-lamp OCT, and Pentacam [J].
Dinc, Umut A. ;
Oncel, Banu ;
Gorgun, Ebru ;
Yalvac, Ilgaz S. .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2010, 20 (03) :531-537
[6]   Optical Coherence Tomography in the Eyes of Normal Children [J].
El-Dairi, Mays A. ;
Asrani, Sanjay G. ;
Enyedi, Laura B. ;
Freedman, Sharon F. .
ARCHIVES OF OPHTHALMOLOGY, 2009, 127 (01) :50-58
[7]   Morphometry of the Trabecular Meshwork In Vivo in a Healthy Population Using Fourier-Domain Optical Coherence Tomography [J].
Fernandez-Vigo, Jose I. ;
Garcia-Feijoo, Julian ;
Martinez-de-la-Casa, Jose M. ;
Garcia-Bella, Javier ;
Fernandez-Vigo, Jose A. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (03) :1782-1788
[8]   Determinants of Angle Width in Chinese Singaporeans [J].
Foo, Li-Lian ;
Nongpiur, Monisha E. ;
Allen, John C. ;
Perera, Shamira A. ;
Friedman, David S. ;
He, Mingguang ;
Cheng, Ching-Yu ;
Wong, Tien Yin ;
Aung, Tin .
OPHTHALMOLOGY, 2012, 119 (02) :278-282
[9]   Age and sex variation in angle findings among normal Chinese subjects [J].
Friedman, David S. ;
Gazzard, Gus ;
Min, Chan Boon ;
Broman, Aimee T. ;
Quigley, Harry ;
Tielsch, James ;
Seah, Steve ;
Foster, Paul J. .
JOURNAL OF GLAUCOMA, 2008, 17 (01) :5-10
[10]   Ultrasound biomicroscopic characteristics of the anterior segment in primary congenital glaucoma [J].
Gupta, Viney ;
Jha, Randhir ;
Srinivasan, Geetha ;
Dada, Tanuj ;
Sihota, Ramanjit .
JOURNAL OF AAPOS, 2007, 11 (06) :546-550