Load-shift-numerical evaluation of a new design philosophy for uncemented hip prostheses

被引:21
作者
Goetzen, N [1 ]
Lampe, F
Nassut, R
Morlock, MM
机构
[1] Hamburg Univ Technol, Biomechan Sect, D-21073 Hamburg, Germany
[2] Gen Hosp Barmbek, Dept Orthoped, D-22291 Hamburg, Germany
关键词
prosthesis; stress shielding; biodegradable; micromotion; finite element analysis;
D O I
10.1016/j.jbiomech.2004.01.023
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
All hip replacement prostheses alter the load transfer from the hip joint into the femur by changing the mechanical loading of the proximal femur from an externally to an internally loaded system. This alteration of the load transfer causes stress shielding and might lead to severe bone loss, especially with uncemented prostheses. To minimize these effects, load transfer to the femur should occur as proximal as possible. In order to support sufficient primary stability, however, directly post operative (PO) distal stabilization is reasonable. Consequently, the prostheses have to alter its mechanical characteristics after implantation. This concept is referred to as load-shift concept. Primary stability during the early PO state is provided by a prosthesis shaft, which is widened at the tip by a biodegradable pin. After resorption of the pin load transfer occurs no longer distally. The objective of this study was the numerical evaluation of the load-shift concept. The analysis was performed with a finite element model. Three-dimensional non-linear dynamic gait analyses data were used to evaluate whether the load transfer during walking can be altered effectively by insertion and resorption of a distal pin. Directly PO 38% of the transverse load is transferred through the prosthesis shaft and micromotion of the proximal prostheses tip is below 55 mum. After resorption of the pin, no transverse loads are transferred through the prosthesis shaft. Therefore, the loading of the proximal bone tissue is far more pronounced than in the case of a standard prosthesis, demonstrating the feasibility of the load-shift concept. A balanced degradation of the pin simultaneously with the ingrowth of the prosthesis is expected to reduce hip replacement complications. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:595 / 604
页数:10
相关论文
共 29 条
[1]   Changes in proximal femoral strain after insertion of uncemented standard and customised femoral stems [J].
Aamodt, A ;
Lund-Larsen, J ;
Eine, J ;
Andersen, E ;
Benum, P ;
Husby, OS .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (06) :921-929
[2]   Isoelastic femoral component in primary cementless total hip arthroplasty [J].
Ali, MS ;
Kumar, A .
INTERNATIONAL ORTHOPAEDICS, 2002, 26 (04) :243-246
[3]  
Au Man-Kuan, 1994, Journal of the Formosan Medical Association, V93, P497
[4]   HIP-JOINT LOADING DURING WALKING AND RUNNING, MEASURED IN 2 PATIENTS [J].
BERGMANN, G ;
GRAICHEN, F ;
ROHLMANN, A .
JOURNAL OF BIOMECHANICS, 1993, 26 (08) :969-990
[5]   Hip contact forces and gait patterns from routine activities [J].
Bergmann, G ;
Deuretzbacher, G ;
Heller, M ;
Graichen, F ;
Rohlmann, A ;
Strauss, J ;
Duda, GN .
JOURNAL OF BIOMECHANICS, 2001, 34 (07) :859-871
[6]  
Breusch SJ, 2000, UNFALLCHIRURG, V103, P918, DOI 10.1007/s001130050647
[7]   Altered load history affects periprosthetic bone loss following cementless total hip arthroplasty [J].
Bryan, JM ;
Sumner, DR ;
Hurwitz, DE ;
Tompkins, GS ;
Andriacchi, TP ;
Galante, JO .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1996, 14 (05) :762-768
[8]  
Cameron H U, 1997, Acta Orthop Belg, V63 Suppl 1, P8
[9]  
DUDA NG, 1996, THESIS SHAKER VERLAG
[10]   Early loosening of the stemmed McMinn cup [J].
Eisler, T ;
Svensson, O ;
Muren, C ;
Elmstedt, E .
JOURNAL OF ARTHROPLASTY, 2001, 16 (07) :871-876