Room-temperature ionic liquid assisted fabrication of sensitive electrochemical immunosensor based on ordered macroporous gold film

被引:16
作者
Chen, Xiaojun [1 ,2 ]
Zhou, Jinjun [1 ]
Xuan, Jie [1 ]
Yan, Wei [1 ]
Jiang, Li-Ping [1 ]
Zhu, Jun-Jie [1 ]
机构
[1] Nanjing Univ, Sch Chem & Chem Engn, Key Lab Analyt Chem Life Sci MOE, Nanjing 210093, Peoples R China
[2] Nanjing Univ Technol, Coll Sci, Nanjing 210009, Peoples R China
基金
中国国家自然科学基金;
关键词
SURFACE-PLASMON-RESONANCE; SELF-ASSEMBLED MONOLAYERS; LOW-DENSITY-LIPOPROTEIN; SOL-GEL ENCAPSULATION; HETEROGENEOUS BIOCATALYSTS; IMPEDANCE IMMUNOSENSOR; HOST MATERIALS; ENZYME; ENTRAPMENT; ADDITIVES;
D O I
10.1039/c0an00264j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel label-free highly sensitive electrochemical impedance spectroscopy (EIS) immunosensor was fabricated based on the highly ordered macroporous gold film (HOMGF) in the presence of room-temperature ionic liquid (IL) for the detection of human Apolipoprotein B-100 (ApoB-100). The antibody of ApoB-100 (Ab) was adsorbed directly onto the HOMGF electrode surface and maintained its bioactivity. After the residual active sites at the electrode were passivated by BSA, the mixture of BMIm(+)BF(4)(-) and silica sol was dropped onto the electrode to entrap the adsorbed Ab and BSA molecules firmly. The addition of IL could prevent the inactivation of Ab by releasing alcohol during the sol-gel process, and the conductivity of the IL-gel membrane was increased. Of particular interest is the fact that the fabricated immunosensor could be used at 60 degrees C. This could be attributed to the interconnected porosity of the IL-gel membrane, which can prevent Ab from unfolding and losing its bioactivities. The immunosensor also exhibited a highly sensitive response to ApoB-100 with the lowest concentration of 5 fg mL(-1). The detection of ApoB-100 levels in five sera samples obtained from hospital showed acceptable accuracy with that using commercial immunonephelometry method.
引用
收藏
页码:2629 / 2636
页数:8
相关论文
共 50 条
[1]   Ionic liquids in analytical chemistry [J].
Anderson, Jared L. ;
Armstrong, Daniel W. ;
Wei, Guor-Tzo .
ANALYTICAL CHEMISTRY, 2006, 78 (09) :2892-2902
[2]  
Avnir D, 2006, J MATER CHEM, V16, P1013, DOI 10.1039/5512706h
[3]   Molecularly imprinted polymers for the recognition of proteins: The state of the art [J].
Bossi, A. ;
Bonini, F. ;
Turner, A. P. F. ;
Piletsky, S. A. .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (06) :1131-1137
[4]   Using sugar and amino acid additives to stabilize enzymes within sol-gel derived silica [J].
Brennan, JD ;
Benjamin, D ;
DiBattista, E ;
Gulcev, MD .
CHEMISTRY OF MATERIALS, 2003, 15 (03) :737-745
[5]   An electrochemical impedance immunosensor with signal amplification based on Au-colloid labeled antibody complex [J].
Chen, Huan ;
Jiang, Jian-Hui ;
Huang, Yong ;
Deng, Ting ;
Li, Ji-Shan ;
Shen, Guo-Li ;
Yu, Ru-Qin .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 117 (01) :211-218
[6]   Electrochemical impedance immunosensor based on three-dimensionally ordered macroporous gold film [J].
Chen, Xiaojun ;
Wang, Yuanyuan ;
Zhou, Jinjun ;
Yan, Wei ;
Li, Xinghua ;
Zhu, Jun-Jie .
ANALYTICAL CHEMISTRY, 2008, 80 (06) :2133-2140
[7]  
Cheng TO, 2005, CHINESE MED J-PEKING, V118, P355
[8]   Surface plasmon resonance analysis at a supported lipid monolayer [J].
Cooper, MA ;
Try, AC ;
Carroll, J ;
Ellar, DJ ;
Williams, DH .
BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES, 1998, 1373 (01) :101-111
[9]   Elevated apolipoprotein B-48 and remnant-like particle-cholesterol in heterozygous familial hypercholesterolaemia [J].
Dane-Stewart, CA ;
Watts, GF ;
Mamo, JCL ;
Dimmitt, SB ;
Barrett, PHR ;
Redgrave, TG .
EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2001, 31 (02) :113-117
[10]   Structured thin films as functional components within biosensors [J].
Davis, F ;
Higson, SPJ .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (01) :1-20