Reproducibility and accuracy of non-invasive measurement of infarct size in mice with high-resolution PET/CT

被引:17
作者
Greco, Adelaide [1 ,3 ]
Petretta, Maria Piera [2 ]
Larobina, Michele [4 ]
Gargiulo, Sara [1 ]
Panico, Mariarosaria [4 ]
Nekolla, Stephan G. [5 ]
Esposito, Giovanni [2 ]
Petretta, Mario [2 ]
Brunetti, Arturo [1 ,3 ,4 ]
Cuocolo, Alberto [1 ,4 ]
机构
[1] Univ Naples Federico II, Dept Biomorphol & Funct Sci, I-80131 Naples, Italy
[2] Univ Naples Federico II, Dept Internal Med Cardiovasc & Immunol Sci, I-80131 Naples, Italy
[3] CEINGE Scarl, Naples, Italy
[4] CNR, Inst Biostruct & Bioimages, Naples, Italy
[5] Tech Univ Munich, Nukl Med Klin & Poliklin, Munich, Germany
关键词
Infarct size; measurement; mouse; PET/CT; F-18-FDG; EMISSION COMPUTED-TOMOGRAPHY; REPERFUSION; ISCHEMIA; RATS;
D O I
10.1007/s12350-012-9538-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study assessed the reproducibility and accuracy of 2-deoxy-2[F-18]fluoro-d-glucose (F-18-FDG) for non-invasive quantification of myocardial infarct size in mice by a high-resolution positron emission tomography (PET)/computed tomography (CT) system. Mice were studied by F-18-FDG PET/CT 1 week after induction of myocardial infarction by permanent coronary occlusion or sham procedure. In a subset of mice, PET/CT was repeated 2 days apart to assess the reproducibility of infarct size measurements. Histological analysis was used as reference method to validate imaging data. The average difference in infarct size measurements between the first and the second study was -0.42% +/- A 2.07% (95% confidence interval -2.6 to 1.75) with a repeatability coefficient of 4.05%. At Bland-Altman analysis, the lower and upper limits of agreement between the two repeated studies were -4.46% and 3.63%, respectively, and no correlation between difference and mean was found (P = .89). The concordance correlation coefficient was 0.99 (P < .001) and the intraclass coefficient of correlation was 0.99. A high correlation between PET/CT and histology was found for measurement of infarct size (P < .001). Using Bland-Altman analysis, the mean difference in infarct size measurement (PET/CT minus histology) was 1.9% (95% confidence interval 0.94% to 2.86%). In a mice model of permanent coronary occlusion non-invasive measurement of infarct size with high-resolution F-18-FDG, PET/CT has excellent reproducibility and accuracy. These findings support the use of this methodology in serial studies.
引用
收藏
页码:492 / 499
页数:8
相关论文
共 20 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
Conci E, 2006, J KARDIOL, V13, P239
[3]   Comparison between Dobutamine Echocardiography and single-photon emission computed tomography for interpretive reproducibility [J].
Ferro, Adele ;
Pellegrino, Teresa ;
Spinelli, Letizia ;
Acampa, Wanda ;
Petretta, Mario ;
Cuocolo, Alberto .
AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (08) :1239-1244
[4]  
Hashimoto K, 1996, Ann Nucl Med, V10, P93
[5]  
Higuchi T, 2007, J NUCL MED, V48, P288
[6]   Surgical animal models of heart failure related to coronary heart disease [J].
Klocke, Rainer ;
Tian, Wen ;
Kuhlmann, Michael T. ;
Nikol, Sgrid .
CARDIOVASCULAR RESEARCH, 2007, 74 (01) :29-38
[7]   Noninvasive measurement of myocardial activity concentrations and perfusion defect sizes in rats with a new small-animal positron emission tomograph [J].
Kudo, T ;
Fukuchi, K ;
Annala, AJ ;
Chatziioannou, AF ;
Allada, V ;
Dahlbom, M ;
Tai, YC ;
Inubushi, M ;
Huang, SC ;
Cherry, SR ;
Phelps, ME ;
Schelbert, HR .
CIRCULATION, 2002, 106 (01) :118-123
[8]   PET/MRI of Inflammation in Myocardial Infarction [J].
Lee, Won Woo ;
Marinelli, Brett ;
van der Laan, Anja M. ;
Sena, Brena F. ;
Gorbatov, Rostic ;
Leuschner, Florian ;
Dutta, Partha ;
Iwamoto, Yoshiko ;
Ueno, Takuya ;
Begieneman, Mark P. V. ;
Niessen, Hans W. M. ;
Piek, Jan J. ;
Vinegoni, Claudio ;
Pittet, Mikael J. ;
Swirski, Filip K. ;
Tawakol, Ahmed ;
Di Carli, Marcelo ;
Weissleder, Ralph ;
Nahrendorf, Matthias .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (02) :153-163
[9]   A CONCORDANCE CORRELATION-COEFFICIENT TO EVALUATE REPRODUCIBILITY [J].
LIN, LI .
BIOMETRICS, 1989, 45 (01) :255-268
[10]  
Liu ZL, 2002, J NUCL MED, V43, P933