Determination of inorganic selenium species in water and garlic samples with on-line ionic liquid dispersive microextraction and electrothermal atomic absorption spectrometry

被引:79
作者
Martinis, Estefania M. [1 ]
Escudero, Leticia B. [1 ]
Berton, Paula [1 ]
Monasterio, Romina P. [1 ,2 ]
Filippini, Maria F. [3 ]
Wuilloud, Rodolfo G. [1 ,4 ]
机构
[1] LISAMEN CCT CONICET Mendoza, Analyt Chem Res & Dev Grp QUIANID, Mendoza, Argentina
[2] Univ Nacl La Pampa, Dept Quim, Fac Ciencias Exactas & Nat, Santa Rosa, Argentina
[3] Univ Nacl Cuyo, Dept Ingn Agr, Catedra Quim Agr, Fac Ciencias Agr, RA-5500 Mendoza, Argentina
[4] Univ Nacl Cuyo, ICB, RA-5500 Mendoza, Argentina
关键词
Tetradecyl(trihexyl)phosphonium chloride; Ionic liquid; Selenium; Liquid-liquid microextraction; Preconcentration; Speciation; SENSITIVE DETERMINATION; HYDRIDE-GENERATION; PRECONCENTRATION; SPECIATION; SYSTEM; FOOD; COMBINATION; SEPARATION; CADMIUM; LEAD;
D O I
10.1016/j.talanta.2011.07.065
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A non-chromatographic separation and preconcentration method for Se species determination based on the use of an on-line ionic liquid (IL) dispersive microextraction system coupled to electrothermal atomic absorption spectrometry (ETAAS) is proposed. Retention and separation of the IL phase was achieved with a Florisil (R)-packed microcolumn after dispersive liquid-liquid microextraction (DLLME) with tetradecyl(trihexyl)phosphonium chloride IL (CYPHOS (R) IL 101). Selenite [Se(IV)] species was selectively separated by forming Se-ammonium pyrrolidine dithiocarbamate (Se-APDC) complex followed by extraction with CYPHOS (R) IL 101. The methodology was highly selective towards Se(IV), while selenate [Se(VI)] was reduced and then indirectly determined. Several factors influencing the efficiency of the preconcentration technique, such as APDC concentration, sample volume, extractant phase volume, type of eluent, elution flow rate, etc., have been investigated in detail. The limit of detection (LOD) was 15 ng L-1 and the relative standard deviation (RSD) for 10 replicates at 0.5 mu g L-1 Se concentration was 5.1%, calculated with peak heights. The calibration graph was linear and a correlation coefficient of 0.9993 was achieved. The method was successfully employed for Se speciation studies in garlic extracts and water samples. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:2182 / 2188
页数:7
相关论文
共 35 条
  • [1] Combination of ionic liquid-based dispersive liquid-liquid micro-extraction with stopped-flow spectrofluorometry for the pre-concentration and determination of aluminum in natural waters, fruit juice and food samples
    Abdolmohammad-Zadeh, H.
    Sadeghi, G. H.
    [J]. TALANTA, 2010, 81 (03) : 778 - 785
  • [2] Hollow fiber based-liquid phase microextraction using ionic liquid solvent for preconcentration of lead and nickel from environmental and biological samples prior to determination by electrothermal atomic absorption spectrometry
    Abulhassani, Jafar
    Manzoori, Jamshid L.
    Amjadi, Mohammad
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2010, 176 (1-3) : 481 - 486
  • [3] Cold-induced aggregation microextraction: A novel sample preparation technique based on ionic liquids
    Baghdadi, Majid
    Shemirani, Farzaneh
    [J]. ANALYTICA CHIMICA ACTA, 2008, 613 (01) : 56 - 63
  • [4] Development of an on-line temperature-assisted ionic liquid dispersive microextraction system for sensitive determination of vanadium in environmental and biological samples
    Berton, Paula
    Martinis, Estefania M.
    Wuilloud, Rodolfo G.
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2010, 176 (1-3) : 721 - 728
  • [5] Room temperature ionic liquid-based microextraction for vanadium species separation and determination in water samples by electrothermal atomic absorption spectrometry
    Berton, Paula
    Martinis, Estefania M.
    Martinezc, Luis D.
    Wuilloud, Rodolfo G.
    [J]. ANALYTICA CHIMICA ACTA, 2009, 640 (1-2) : 40 - 46
  • [6] Selenium analysis in water samples by dispersive liquid-liquid microextraction based on piazselenol formation and GC-ECD
    Bidari, Araz
    Hemmatkhah, Payam
    Jafarvand, Sanaz
    Hosseini, Mohammad Reza Milani
    Assadi, Yaghoub
    [J]. MICROCHIMICA ACTA, 2008, 163 (3-4) : 243 - 249
  • [7] Ionic liquids improved reversed-phase HPLC on-line coupled with ICP-MS for selenium speciation
    Chen, Beibei
    He, Man
    Mao, Xiangju
    Cui, Ran
    Pang, Daiwen
    Hu, Bin
    [J]. TALANTA, 2011, 83 (03) : 724 - 731
  • [8] Cheng K.L., 1982, Handbook of Organic Analytical Reagents
  • [9] CYTEC, 2004, CYPHOS IL 101 DAT SH
  • [10] Fang Z., 1993, Flow Injection Separation and Preconcentration