Tissue-Specific T2* Biomarkers in Patellar Tendinopathy by Subregional Quantification Using 3D Ultrashort Echo Time MRI

被引:12
作者
Breda, Stephan J. [1 ,2 ]
Poot, Dirk H. J. [1 ]
Papp, Dorottya [1 ]
de Vries, Bas A. [1 ]
Kotek, Gyula [1 ]
Krestin, Gabriel P. [1 ]
Hernandez-Tamames, Juan A. [1 ]
de Vos, Robert-Jan [2 ]
Oei, Edwin H. G. [1 ]
机构
[1] Univ Med Ctr Rotterdam, Erasmus MC, Dept Radiol & Nucl Med, Rotterdam, Netherlands
[2] Univ Med Ctr Rotterdam, Erasmus MC, Dept Orthoped & Sports Med, Rotterdam, Netherlands
关键词
magnetic resonance imaging; image processing; reproducibility of results; patellar ligament; tendinopathy; biomarkers; T2-ASTERISK ANALYSIS; MAGNETIC-RESONANCE; JUMPERS KNEE; IN-VIVO; TENDON; DIFFUSION; RELAXATION; HEALTHY; SPORTS; WATER;
D O I
10.1002/jmri.27108
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Quantitative MRI of patellar tendinopathy (PT) can be challenging due to spatial variation of T-2* relaxation times. Purpose 1) To compare T-2* quantification using a standard approach with analysis in specific tissue compartments of the patellar tendon. 2) To evaluate test-retest reliability of different methods for fitting ultrashort echo time (UTE)-relaxometry data. Study Type Prospective. Subjects Sixty-five athletes with PT. Field Strength/Sequence 3D UTE scans covering the patellar tendon were acquired using a 3.0T scanner and a 16-channel surface coil. Assessment Voxelwise median T-2* was quantified with monoexponential, fractional-order, and biexponential fitting. We applied two methods for T-2* analysis: first, a standard approach by analyzing all voxels covering the proximal patellar tendon. Second, within subregions of the patellar tendon, by using thresholds on biexponential fitting parameter percentage short T-2* (0-30% for mostly long T-2*, 30-60% for mixed T-2*, and 60-100% for mostly short T-2*). Statistical Tests Average test-retest reliability was assessed in three athletes using coefficients-of-variation (CV) and coefficients-of-repeatability (CR). Results With standard image analysis, we found a median [interquartile range, IQR] monoexponential T-2* of 6.43 msec [4.32-8.55] and fractional order T-2* 4.39 msec [3.06-5.78]. The percentage of short T-2* components was 52.9% [35.5-69.6]. Subregional monoexponential T-2* was 13.78 msec [12.11-16.46], 7.65 msec [6.49-8.61], and 3.05 msec [2.52-3.60] and fractional order T-2* 11.82 msec [10.09-14.44], 5.14 msec [4.25-5.96], and 2.19 msec [1.82-2.64] for 0-30%, 30-60%, and 60-100% short T-2*, respectively. Biexponential component short T-2* was 1.693 msec [1.417-2.003] for tissue with mostly short T-2* and long T-2* of 15.79 msec [13.47-18.61] for mostly long T-2*. The average CR (CV) was 2 msec (15%), 2 msec (19%) and 10% (22%) for monoexponential, fractional order and percentage short T-2*, respectively. Data Conclusion Patellar tendinopathy is characterized by regional variability in binding states of water. Quantitative multicompartment T-2* analysis in PT can be facilitated using a voxel selection method based on using biexponential fitting parameters. Level of Evidence 1 Technical Efficacy Stage 1
引用
收藏
页码:420 / 430
页数:11
相关论文
共 34 条
[1]   Maximum a posteriori estimation of diffusion tensor parameters using a Rician noise model: Why, how and but [J].
Andersson, Jesper L. R. .
NEUROIMAGE, 2008, 42 (04) :1340-1356
[2]   Greater glycosaminoglycan content in human patellar tendon biopsies is associated with more pain and a lower VISA score [J].
Attia, Mohamed ;
Scott, Alexander ;
Carpentier, Gilles ;
Lian, Oystein ;
Van Kuppevelt, Toin ;
Gossard, Camille ;
Papy-Garcia, Dulce ;
Tassoni, Marie-Claude ;
Martelly, Isabelle .
BRITISH JOURNAL OF SPORTS MEDICINE, 2014, 48 (06) :469-475
[3]   Assessment of sports participation levels following knee injuries [J].
Barber-Westin, SD ;
Noyes, FR .
SPORTS MEDICINE, 1999, 28 (01) :1-10
[4]  
Bland JM, 1996, BRIT MED J, V313, P744
[5]   Quantitative bi-component T2* analysis of histologically normal Achilles tendons [J].
Chang, Eric Y. ;
Du, Jiang ;
Statum, Sheronda ;
Pauli, Chantal ;
Chung, Christine B. .
MLTJ-MUSCLES LIGAMENTS AND TENDONS JOURNAL, 2015, 5 (02) :58-62
[6]   UTE Imaging in the Musculoskeletal System [J].
Chang, Eric Y. ;
Du, Jiang ;
Chung, Christine B. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (04) :870-883
[7]   Evaluation of bound and pore water in cortical bone using ultrashort-TE MRI [J].
Chen, Jun ;
Grogan, Shawn P. ;
Shao, Hongda ;
D'Lima, Darryl ;
Bydder, Graeme M. ;
Wu, Zhihong ;
Du, Jiang .
NMR IN BIOMEDICINE, 2015, 28 (12) :1754-1762
[8]   The impact of patellar tendinopathy on sports and work performance in active athletes [J].
De Vries, Astrid J. ;
Koolhaas, Wendy ;
Zwerver, Johannes ;
Diercks, Ron L. ;
Nieuwenhuis, Kari ;
Van der Worp, Henk ;
Brouwer, Sandra ;
Van den Akker-Scheek, Inge .
RESEARCH IN SPORTS MEDICINE, 2017, 25 (03) :253-265
[9]   Optimization of Iron Oxide Nanoparticle Detection Using Ultrashort Echo Time Pulse Sequences: Comparison of T1, T*2, and Synergistic T1-T*2 Contrast Mechanisms [J].
Girard, O. M. ;
Du, J. ;
Agemy, L. ;
Sugahara, K. N. ;
Kotamraju, V. R. ;
Ruoslahti, E. ;
Bydder, G. M. ;
Mattrey, R. F. .
MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (06) :1649-1660
[10]   Tendon and ligament imaging [J].
Hodgson, R. J. ;
O'Connor, P. J. ;
Grainger, A. J. .
BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1016) :1157-1172