Piecewise direct standardization method applied to the simultaneous determination of Pb(II), Sn(IV) and Cd(II) by differential pulse polarography

被引:1
作者
Herrero, A [1 ]
Ortiz, MC [1 ]
机构
[1] Univ Burgos, Fac Ciencias, Dept Quim, E-09001 Burgos, Spain
关键词
piecewise direct standardization; partial least squares regression; multianalyte determination; overlapping signals; differential pulse polarography;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A partial least squares (PLS) regression has been used to carry out the simultaneous determination of Pb(II), Sn(IV) and Cd(II) by differential pulse polarography (DPP) because overlapping peaks exist. But this multivariate regression requires the measurement of a large number of calibration samples, so a standardization procedure, the piecewise direct standardization (PDS) method, has been used in order to reduce the experimental effort that will be necessary in later analysis. The number of calibration samples has been reduced by about 60%, the results being comparable to those obtained with a full recalibration.
引用
收藏
页码:717 / 721
页数:5
相关论文
共 27 条
[1]   SIMULTANEOUS DETERMINATION OF LEAD AND TIN IN BIOLOGICAL AND ENVIRONMENTAL MATERIALS BY DIFFERENTIAL-PULSE CATHODIC VOLTAMMETRY ON A GLASSY-CARBON MERCURY FILM ELECTRODE [J].
ADELOJU, SBO ;
PABLO, F .
ELECTROANALYSIS, 1995, 7 (08) :750-755
[2]  
ANDERSON VL, 1974, STAT TXB MONOGRAPHS, V5
[3]   Standardisation of near-infrared spectrometric instruments: A review [J].
Bouveresse, E ;
Massart, DL .
VIBRATIONAL SPECTROSCOPY, 1996, 11 (01) :3-15
[4]   RESOLUTION OF OVERLAPPED ELECTROCHEMICAL PEAKS WITH THE USE OF THE KALMAN FILTER [J].
BROWN, TF ;
BROWN, SD .
ANALYTICAL CHEMISTRY, 1981, 53 (09) :1410-1417
[5]   SIMULTANEOUS DETERMINATION OF TIN AND LEAD AT THE PARTS-PER-BILLION LEVEL BY COUPLING DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY WITH A MATRIX EXCHANGE METHOD [J].
DESIMONI, E ;
PALMISANO, F ;
SABBATINI, L .
ANALYTICAL CHEMISTRY, 1980, 52 (12) :1889-1892
[6]  
FLORENCE TM, 1974, J ELECTROANAL CHEM, V51, P191, DOI 10.1016/0368-1874(74)87017-6
[7]   TRANSFER OF CALIBRATION FUNCTION IN NEAR-INFRARED SPECTROSCOPY [J].
FORINA, M ;
DRAVA, G ;
ARMANINO, C ;
BOGGIA, R ;
LANTERI, S ;
LEARDI, R ;
CORTI, P ;
CONTI, P ;
GIANGIACOMO, R ;
GALLIENA, C ;
BIGONI, R ;
QUARTARI, I ;
SERRA, C ;
FERRI, D ;
LEONI, O ;
LAZZERI, L .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1995, 27 (02) :189-203
[8]   SIMULTANEOUS DETERMINATION OF TIN AND LEAD BY ANODIC-STRIPPING VOLTAMMETRY WITH ADDITION OF SURFACTANT [J].
GEORGES, J ;
MERMET, M .
ANALYTICA CHIMICA ACTA, 1986, 185 :363-368
[9]   CYCLIC AND STRIPPING VOLTAMMETRY OF TIN AT MERCURY HANGING DROP AND FILM ELECTRODES IN ACIDIC ORTHO-DIPHENOL MEDIA IN THE PRESENCE OF LEAD AND CADMIUM [J].
GLODOWSKI, S ;
KUBLIK, Z .
ANALYTICA CHIMICA ACTA, 1980, 115 (MAR) :51-60
[10]   CYCLIC AND STRIPPING VOLTAMMETRY OF TIN IN THE PRESENCE OF LEAD IN PYROGALLOL MEDIUM AT HANGING AND FILM MERCURY-ELECTRODES [J].
GLODOWSKI, S ;
KUBLIK, Z .
ANALYTICA CHIMICA ACTA, 1979, 104 (01) :55-65