A Non-Invasive Blood Insulin and Glucose Monitoring System based on Near-Infrared Spectroscopy with Remote Data Logging

被引:2
|
作者
Nandi, Bodhayan [1 ]
Mondal, Prosenjit [2 ]
Chowdhury, Shubhajit Roy [1 ]
机构
[1] Indian Inst Technol Mandi, Sch Comp & Elect Engn, Mandi, Himachal Prades, India
[2] Indian Inst Technol Mandi, Sch Basic Sci, Mandi, Himachal Prades, India
来源
2018 31ST IEEE INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS (CBMS 2018) | 2018年
关键词
Near-Infrared; Non-Invasive; Insulin; Glucose; Photoplethysmography; Microcontroller; BIOSENSOR; SENSOR;
D O I
10.1109/CBMS.2018.00055
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents the development of a portable, Non-Invasive device for monitoring patients' blood Insulin and Glucose concentration. It is based on Near-Infrared(NIR) Spectroscopy. Perkin-Elmer Lambda 750 spectrometer was used to study the absorbance of Insulin and glucose at different wavelengths of NIR region. NIR LED (Light Emitting diode) of appropriate wavelengths were used to construct a finger clip. A separate Printed Circuit Board (PCB) was constructed; that connects to the finger clip and acquires the Photoplethysmography (PPG) signal at three separate NIR wavelengths. The PPG signal can be used to detect the concentartion of Glucose and Insulin in blood. The PCB has a WiFi module interfaced within it; that supports Internet connectivity and uploads the time series data of insulin and glucose to a server. The data can be viewed in a graphical format by authorized users. This can be used by a medical practitioner to understand whether the data shows an increasing or decreasing trend and hence, will enable to prognosticate the approaching critical condition of the patient much before the critical condition actually occurs.
引用
收藏
页码:274 / 279
页数:6
相关论文
共 50 条
  • [31] Development of non-invasive blood glucose regression based on near-infrared spectroscopy combined with a deep-learning method
    Wang, Zhuyu
    Zhou, Linhua
    Liu, Tianqing
    Huan, Kewei
    Jia, Xiaoning
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2022, 55 (21)
  • [32] Functional near-infrared spectroscopy in non-invasive neuromodulation
    Congcong Huo
    Gongcheng Xu
    Hui Xie
    Tiandi Chen
    Guangjian Shao
    Jue Wang
    Wenhao Li
    Daifa Wang
    Zengyong Li
    Neural Regeneration Research, 2024, 19 (07) : 1517 - 1522
  • [33] Research of transmissive near infrared spectroscopy for non-invasive blood glucose measurement
    Yang, Wenming
    Liao, Ningfang
    Li, Yasheng
    Shao, Liwei
    Huang, Dehuang
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS VII, 2017, 0024
  • [34] Near-Infrared Spectroscopy (NIRS) for Non-Invasive Diagnosis
    Baig, Saeeda
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2023, 33 (11): : 1215 - 1216
  • [35] Functional near-infrared spectroscopy in non-invasive neuromodulation
    Huo, Congcong
    Xu, Gongcheng
    Xie, Hui
    Chen, Tiandi
    Shao, Guangjian
    Wang, Jue
    Li, Wenhao
    Wang, Daifa
    Li, Zengyong
    NEURAL REGENERATION RESEARCH, 2024, 19 (07) : 1517 - 1522
  • [36] Non-invasive Blood Glucose Measurement Based on ATR Infrared Spectroscopy
    Ishizawa, Hiroaki
    Muro, Akinobu
    Takano, Tomohiro
    Honda, Kazuya
    Kanai, Hiroyuki
    2008 PROCEEDINGS OF SICE ANNUAL CONFERENCE, VOLS 1-7, 2008, : 292 - 295
  • [37] An optimized non-invasive glucose sensing based on scattering and absorption separating using near-infrared spectroscopy
    Han, Tongshuai
    Liu, Xueyu
    Liu, Jin
    Xu, Kexin
    OPTICAL DIAGNOSTICS AND SENSING XIX: TOWARD POINT-OF-CARE DIAGNOSTICS, 2019, 10885
  • [38] Net analyte signal with floating reference theory in non-invasive blood glucose sensing by near-infrared spectroscopy
    Zhang, Wanjie
    Liu, Rong
    Zhang, Wen
    Zheng, Jiaxiang
    Xu, Kexin
    CHINESE OPTICS LETTERS, 2012, 10 (08)
  • [39] Net analyte signal with floating reference theory in non-invasive blood glucose sensing by near-infrared spectroscopy
    张婉洁
    刘蓉
    张雯
    郑加祥
    徐可欣
    ChineseOpticsLetters, 2012, 10 (08) : 74 - 77
  • [40] Non-Invasive Blood Glucose Measurement Based on Near-Infrared Spectroscopy Combined With Label Sensitivity Algorithm and Support Vector Machine
    Meng Qi
    Zhao Peng
    Huan Ke-wei
    Li Ye
    Jiang Zhi-xia
    Zhang Han-wen
    Zhou Lin-hua
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44 (03) : 617 - 624