Performance and quality control of Clear-PEM detector modules

被引:14
作者
Amaral, Pedro
Carrico, Bruno
Ferreira, Miguel
Moura, Rui
Ortigao, Catarina
Rodrigues, Pedro
Da Silva, Jose C.
Trindade, Andreia
Varela, Joao
机构
[1] LIP, P-100149 Lisbon, Portugal
[2] IST, P-1049001 Lisbon, Portugal
关键词
positron emission mammography; LYSO; APD; energy resolution; depth-of-interaction; DoI resolution;
D O I
10.1016/j.nima.2007.06.071
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Clear-PEM is a dedicated PET scanner for breast and axilla cancer diagnosis, under development within the framework of the Crystal Clear Collaboration at CERN, aiming at the detection of tumors down to 2 mm in diameter. The camera consists of two planar detector heads with active dimensions 16.0 x 14.5 cm(2). Each head has 96 Clear-PEM detector modules consisting of 32 LYSO:Ce pixels with dimensions 2 x 2 x 20 mm(3) packed in a 4 x 8 BaSO4 reflector matrix compressed between two Hamamatsu S8550 APD arrays in a double-readout configuration for Depth-of-Interaction (DoI) determination. The modules are individually measured and characterized before being grouped into Supermodules (comprised of 24 modules). Measured properties include photo-peak position, relative gain dispersion, energy resolution, cross-talk and Dol resolution. Optical inspection of matrices was also performed with the aid of a microscope, to search for pixel misalignments and matrix defects. Modules' performance was thoroughly evaluated with a 511 keV collimated beam to exactly determine Dol resolution. In addition, a fast quality control (QC) procedure using flood irradiations from a (CS)-C-137 source was applied systematically. The overall performance of the 24 detector modules complies with the design goals of the Clear-PEM detector, showing energy resolution around 15%, Dol resolution of about 2 mm and gain dispersion among pixels of 15%. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:1123 / 1126
页数:4
相关论文
共 7 条
[1]   Design and evaluation of the Clear-PEM scanner for positron emission mammography [J].
Abreu, MC ;
Aguiar, JD ;
Almeida, FG ;
Almeida, P ;
Bento, P ;
Carrico, B ;
Ferreira, M ;
Ferreira, NC ;
Gonçalves, F ;
Leong, C ;
Lopes, F ;
Lousa, P ;
Martins, MV ;
Matela, N ;
Mendes, PR ;
Moura, R ;
Nobre, J ;
Oliveira, N ;
Ortigao, C ;
Peralta, L ;
Pereira, R ;
Rego, J ;
Ribeiro, R ;
Rodrigues, P ;
Sampaio, J ;
Santos, AI ;
Silva, L ;
Silva, JC ;
Sousa, P ;
Teixeira, IC ;
Teixeira, JP ;
Trindade, A ;
Varela, J .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) :71-77
[2]  
CARRICO B, 2006, IWORID 2006 IT 2 3 J
[3]   Measurement of the depth of interaction of an LSO scintillator using a planar process APD [J].
Gramsch, E ;
Avila, RE ;
Bui, P .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (03) :307-312
[4]   Statistical studies on the light output and energy resolution of small LSO single crystals with different surface treatments combined with various reflector materials [J].
Heinrichs, U ;
Blume, A ;
Bussmann, N ;
Engels, R ;
Kemmerling, G ;
Weber, S ;
Ziemons, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 486 (1-2) :60-66
[5]   An LSO scintillator array for a PET detector module with depth of interaction measurement [J].
Huber, JS ;
Moses, WW ;
Andreaco, MS ;
Petterson, O .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) :684-688
[6]   Clear-PEM, a dedicated PET camera for mammography [J].
Lecoq, P ;
Varela, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 486 (1-2) :1-6
[7]  
ORTIGAO C, 2006, LONG TERM STABILITY