A microfluidic chemiluminescence biosensor based on multiple signal amplification for rapid and sensitive detection of E. coli O157:H7

被引:76
作者
Sun, Dongli [1 ]
Fan, Tingting [1 ]
Liu, Feng [1 ]
Wang, Fangxiu [3 ]
Gao, Dan [1 ]
Lin, Jin-Ming [2 ]
机构
[1] Tsinghua Univ, Tsinghua Shenzhen Int Grad Sch, State Key Lab Chem Oncogen, Key Lab Chem Biol, Shenzhen 518055, Peoples R China
[2] Tsinghua Univ, Dept Chem, Beijing Key Lab Microanalyt Methods & Instrumenta, Key Lab Bioorgan Phosphorus Chem & Chem Biol, Beijing 100084, Peoples R China
[3] Shenzhen Lvshiyuan Biotechnol Co Ltd, Shenzhen 518120, Peoples R China
关键词
Microfluidic chip; Catalytic hairpin assembly; Chemiluminescence; Au NPs; E. coli O157:H7; PLATFORM;
D O I
10.1016/j.bios.2022.114390
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
E. coli O157:H7 has become a crucial foodborne pathogen with certain morbidity and mortality. However, the available methods still face the significant challenges including the improvement of detection specificity and sensitivity for real sample analysis. Herein, a microfluidic chemiluminescence biosensor based on a multiple signal amplification strategy was developed for rapid and ultrasensitive detection of E. coli O157:H7. The microfluidic device was consisted of an upstream snake-shape mixing channel and a downstream ship-shape microcavity with micropillar array for high efficient mixing of CL reagents, sufficient CHA amplification reaction and CL reaction. The multiple signal amplification was achieved by bacteria competitively bind to trigger catalytic hairpin assembly (CHA) and HRP-Au NPs catalyzed CL reaction. Based on the platform, the detection of target bacteria is converted to the detection of nucleic acid with a limit detection down to 130 CFU/mL, which is better or comparable to previously reported biosensors. Moreover, the whole analysis time was about 1.5 h with only 10 mu L. of sample. The biosensor exhibited an excellent recovery rate ranged from 90.0% to 110.0% and good selectivity to the target bacteria. Overall, this developed biosensor is a promising tool for ultrahigh sensitive and rapid detection of foodborne pathogens.
引用
收藏
页数:8
相关论文
共 49 条
[21]   Microfluidics for the rapid detection of Escherichia coli O157:H7 using antibody-coated microspheres [J].
Song, Bo ;
Yu, Jiayuan ;
Sun, Yan ;
Wang, Qiao ;
Xu, Shengnan ;
Jia, Yichen ;
Lin, Shuying ;
Zhang, Yueying ;
Wang, Chen ;
Zhang, Yingbo ;
Zhang, Xiaojie .
BIOENGINEERED, 2021, 12 (01) :392-401
[22]   Carbon dots and covalent organic frameworks based FRET immunosensor for sensitive detection of Escherichia coli O157:H7 [J].
Wang, Sunli ;
Liang, Nini ;
Hu, Xuetao ;
Li, Wenting ;
Guo, Ziang ;
Zhang, Xinai ;
Huang, Xiaowei ;
Li, Zhihua ;
Zou, Xiaobo ;
Shi, Jiyong .
FOOD CHEMISTRY, 2024, 447
[23]   Rapid Visualized Detection of Escherichia Coli O157. H7 by DNA Hydrogel Based on Rolling Circle Amplification [J].
Zhang, Tong ;
Tao, Qing ;
Bian, Xiao-Jun ;
Chen, Qian ;
Yan, Juan .
CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 49 (03) :377-386
[24]   Customized AIEgen-Based Molecular Signaling Tags Combined Microfluidic Chip for Point-of-Care Testing Viable E. coli O157:H7 [J].
Feng, Niu ;
Li, Yiqi ;
Zhao, Yongkun ;
Tao, Jiacheng ;
Jiang, Hong ;
Wang, Shu ;
Huang, Xiaolin ;
Ma, Jimei ;
Tang, Ben Zhong .
ACS SENSORS, 2025, 10 (02) :785-794
[25]   A chemiluminescence fiber-optic biosensor coupled with immunomagnetic separation for rapid detection of E-coli O15:H7 [J].
Ye, J ;
Liu, Y ;
Li, Y .
TRANSACTIONS OF THE ASAE, 2002, 45 (02) :473-478
[26]   Novel ELISA based on fluorescent quenching of DNA-stabilized silver nanoclusters for detecting E. coli O157:H7 [J].
Wang, Chun ;
Xing, Keyu ;
Zhang, Ganggang ;
Yuan, Meifang ;
Xu, Shaolan ;
Liu, Daofeng ;
Chen, Wenyao ;
Peng, Juan ;
Hu, Song ;
Lai, Wei-Hua .
FOOD CHEMISTRY, 2019, 281 :91-96
[27]   One-pot rapid visual detection of E. coli O157:H7 by label-free AuNP-based plasmonic-aptasensor in water sample [J].
Shirzad, Hadi ;
Panji, Mohammad ;
Nezhad, Seyed Amin Mousavi ;
Houshmand, Pouya ;
Tamai, Iradj Ashrafi .
JOURNAL OF MICROBIOLOGICAL METHODS, 2024, 217
[28]   Enzyme-linked immunomagnetic chemiluminescent detection of Escherichia coli O157:H7 [J].
Gehring, AG ;
Irwin, PL ;
Reed, SA ;
Tu, SI ;
Andreotti, PE ;
Akhavan-Tafti, H ;
Handley, RS .
JOURNAL OF IMMUNOLOGICAL METHODS, 2004, 293 (1-2) :97-106
[29]   Point-of-care detection of Escherichia coli O157:H7 in water using AuNPs-based aptasensor [J].
Soheili, Vahid ;
Taghdisi, Seyed Mohammad ;
Abnous, Khalil ;
Ebrahimi, Mohsen .
IRANIAN JOURNAL OF BASIC MEDICAL SCIENCES, 2020, 23 (07) :901-908
[30]   Electrical determination of E-coli O157:H7 using tin-oxide nanowire coupled with microfluidic chip [J].
Huang, XingJiu ;
Zhang, YingYing .
IEEE SENSORS JOURNAL, 2006, 6 (06) :1376-1377