Performance evaluation of large solar photovoltaic power plants in Spain

被引:78
作者
Martin-Martinez, S. [1 ]
Canas-Carreton, M. [1 ,2 ]
Honrubia-Escribano, A. [1 ,2 ]
Gomez-Lazaro, E. [1 ,2 ]
机构
[1] Univ Castilla La Mancha, Renewable Energy Res Inst, Albacete 02071, Spain
[2] Univ Castilla La Mancha, DIEEAC ETSII Ab, Albacete 02071, Spain
关键词
Energy yield; Performance ratio; PV plant monitoring; Solar PV; Solar tracking system; PARAMETERS; MODULES; SYSTEM;
D O I
10.1016/j.enconman.2018.12.116
中图分类号
O414.1 [热力学];
学科分类号
摘要
This work presents a comprehensive study of the performance of six large photovoltaic (PV) power plants with different mounting topologies over several years of operation. This is a marked contrast to most available performance studies which focus on the study of a single installation of low rated power and one mounting type. The performance results are obtained following the guidelines of Standard IEC 61724 and largely coincide with those expected considering the plants' location in the South-Central Region of Spain, with a total system efficiency ranging between 10% and 12%. Moreover, some performance trends are identified and associated with mounting system, size and location. Finally, it is concluded that the added complexity of dual-axis tracking systems in the operation and maintenance was underestimated in the design phase of the PV power plants. Wind speed has emerged as a key parameter, not only due to the cooling effect on the PV panels but also as a result of its impact on the availability of energy generation.
引用
收藏
页码:515 / 528
页数:14
相关论文
共 32 条
[21]   Photovoltaic Degradation Rates-an Analytical Review [J].
Jordan, D. C. ;
Kurtz, S. R. .
PROGRESS IN PHOTOVOLTAICS, 2013, 21 (01) :12-29
[22]   Performance ratio - Crucial parameter for grid connected PV plants [J].
Khalid, Ahmad Mohd ;
Mitra, Indradip ;
Warmuth, Werner ;
Schacht, Volker .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 65 :1139-1158
[23]   Performance evaluation of 10 MW grid connected solar photovoltaic power plant in India [J].
Kumar, B. Shiva ;
Sudhakar, K. .
ENERGY REPORTS, 2015, 1 :184-192
[24]   Performance analysis of a grid connected photovoltaic park on the island of Crete [J].
Kymakis, Emmanuel ;
Kalykakis, Sofoklis ;
Papazoglou, Thales M. .
ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (03) :433-438
[25]   Long term performance, losses and efficiency analysis of a 960 kWp photovoltaic system in the Mediterranean climate [J].
Malvoni, M. ;
Leggieri, A. ;
Maggiotto, G. ;
Congedo, P. M. ;
De Giorgi, M. G. .
ENERGY CONVERSION AND MANAGEMENT, 2017, 145 :169-181
[26]   Performance parameters for grid-connected PV systems [J].
Marion, B ;
Adelstein, J ;
Boyle, K ;
Hayden, H ;
Hammond, B ;
Fletcher, T ;
Canada, B ;
Narang, D ;
Kimber, A ;
Mitchell, L ;
Rich, G ;
Townsend, T .
Conference Record of the Thirty-First IEEE Photovoltaic Specialists Conference - 2005, 2005, :1601-1606
[27]   Yield and performance analysis of the first grid-connected solar farm at Moshoeshoe I International Airport, Lesotho [J].
Mpholo, Moeketsi ;
Nchaba, Teboho ;
Monese, Molebatsi .
RENEWABLE ENERGY, 2015, 81 :845-852
[28]   Performance analysis of a 3 MWp grid connected solar photovoltaic power plant in India [J].
Padmavathi, K. ;
Daniel, S. Arul .
ENERGY FOR SUSTAINABLE DEVELOPMENT, 2013, 17 (06) :615-625
[29]   Review of photovoltaic degradation rate methodologies [J].
Phinikarides, Alexander ;
Kindyni, Nitsa ;
Makrides, George ;
Georghiou, George E. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 40 :143-152
[30]   Performance analysis of the first large-scale (15 MWp) grid-connected photovoltaic plant in Mauritania [J].
Sidi, Cheikh El Banany Elhadj ;
Ndiaye, Mamadou Lamine ;
El Bah, Menny ;
Mbodji, Abdoulkarim ;
Ndiaye, Ababacar ;
Ndiaye, Papa Alioune .
ENERGY CONVERSION AND MANAGEMENT, 2016, 119 :411-421