Agreement of angle closure assessments between gonioscopy, anterior segment optical coherence tomography and spectral domain optical coherence tomography

被引:7
作者
Tay, Elton Lik Tong [1 ,2 ]
Yong, Vernon Khet Yau [1 ]
Lim, Boon Ang [1 ]
Sia, Stelson [3 ]
Wong, Elizabeth Poh Ying [1 ]
Yip, Leonard Wei Leon [1 ]
机构
[1] Tan Tock Seng Hosp, Dept Ophthalmol, Singapore 308433, Singapore
[2] Republ Singapore Air Force Aeromed Ctr, Singapore 539945, Singapore
[3] Cardinal Santos Med Ctr, San Juan 1502, Metro Manila, Philippines
关键词
anterior segment imaging; spectral domain imaging; angle closure assessment; CHAMBER ANGLE; ASSOCIATION; SYSTEM; WIDTH; EYE;
D O I
10.3980/j.issn.2222-3959.2015.02.23
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
AIM: To determine angle closure agreements between gonioscopy and anterior segment optical coherence tomography (AS -OCT), as well as gonioscopy and spectral domain OCT (SD-OCT). A secondary objective was to quantify inter-observer agreements of AS -OCT and SD-OCT assessments. METHODS: Seventeen consecutive subjects (33 eyes) were recruited from the study hospital's Glaucoma clinic. Gonioscopy was performed by a glaucomatologist masked to OCT results. OCT images were read independently by 2 other glaucomatologists masked to gonioscopy findings as well as each other's analyses of OCT images. RESULTS: Totally 84.8% and 45.5% of scleral spurs were visualized in AS -OCT and SD -OCT images respectively (P<0.01). The agreement for angle closure between AS -OCT and gonioscopy was fair at k =0.31 (95% confidence interval, Cl: 0.03-0.59) and k=0.35 (95% Cl: 0.07-0.63) for reader 1 and 2 respectively. The agreement for angle closure between SD-OCT and gonioscopy was fair at k=0.21 (95% Cl: 0.07-0.49) and slight at k=0.17 (95% Cl: 0.08-0.42) for reader 1 and 2 respectively. The inter -reader agreement for angle closure in AS -OCT images was moderate at 0.51 (95% Cl: 0.13-0.88). The Inter -reader agreement for angle closure in SD -OCT images was slight at 0.18 (95% Cl: 0.08-0.45). CONCLUSION: Significant proportion of scleral spurs were not visualised with SD -OCT imaging resulting in weaker inter-reader agreements. Identifying other angle landmarks in SD-OCT images will allow more consistent angle closure assessments. Gonioscopy and OCT imaging do not always agree in angle closure assessments but have their own advantages, and should be used together and not exclusively.
引用
收藏
页码:342 / 346
页数:5
相关论文
共 21 条
[1]   Comparison of the scanning peripheral anterior chamber depth analyzer and the modified van Herick grading system in the assessment of angle closure [J].
Baskaran, Mani ;
Oen, Francis T. S. ;
Chan, Yiong-Huak ;
Hoh, Sek-Tien ;
Ho, Ching-Lin ;
Kashiwagi, Kenji ;
Foster, Pau J. ;
Aung, Tin .
OPHTHALMOLOGY, 2007, 114 (03) :501-506
[2]   Novel anterior-chamber angle measurements by high-definition optical coherence tomography using the Schwalbe line as the landmark [J].
Cheung, Carol Y. ;
Zheng, Ce ;
Ho, Ching-Lin ;
Tun, Tin A. ;
Kumar, Rajesh S. ;
El Sayyad, Fouad ;
Wong, Tien Y. ;
Aung, Tin .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (07) :955-959
[3]  
Foster Paul J, 2002, Semin Ophthalmol, V17, P50
[4]   MICROMETER-SCALE RESOLUTION IMAGING OF THE ANTERIOR EYE IN-VIVO WITH OPTICAL COHERENCE TOMOGRAPHY [J].
IZATT, JA ;
HEE, MR ;
SWANSON, EA ;
LIN, CP ;
HUANG, D ;
SCHUMAN, JS ;
PULIAFITO, CA ;
FUJIMOTO, JG .
ARCHIVES OF OPHTHALMOLOGY, 1994, 112 (12) :1584-1589
[5]   Anterior chamber angle imaging with optical coherence tomography [J].
Leung, C. K-S ;
Weinreb, R. N. .
EYE, 2011, 25 (03) :261-267
[6]   Detection of primary angle closure using anterior segment optical coherence tomography in Asian eyes [J].
Nolan, Winifred P. ;
See, Jovina L. ;
Chew, Paul T. K. ;
Friedman, David S. ;
Smith, Scott D. ;
Radhakrishnan, Sunita ;
Zheng, Ce ;
Foster, Paul J. ;
Aung, Tin .
OPHTHALMOLOGY, 2007, 114 (01) :33-39
[7]   Classification Algorithms Based on Anterior Segment Optical Coherence Tomography Measurements for Detection of Angle Closure [J].
Nongpiur, Monisha E. ;
Haaland, Benjamin A. ;
Friedman, David S. ;
Perera, Shamira A. ;
He, Mingguang ;
Foo, Li-Lian ;
Baskaran, Mani ;
Sakata, Lisandro M. ;
Wong, Tien Y. ;
Aung, Tin .
OPHTHALMOLOGY, 2013, 120 (01) :48-54
[8]   Lens Vault, Thickness, and Position in Chinese Subjects with Angle Closure [J].
Nongpiur, Monisha E. ;
He, Mingguang ;
Amerasinghe, Nishani ;
Friedman, David S. ;
Tay, Wan-Ting ;
Baskaran, Mani ;
Smith, Scott D. ;
Wong, Tien Yin ;
Aung, Tin .
OPHTHALMOLOGY, 2011, 118 (03) :474-479
[9]   Novel Association of Smaller Anterior Chamber Width with Angle Closure in Singaporeans [J].
Nongpiur, Monisha E. ;
Sakata, Lisandro M. ;
Friedman, David S. ;
He, Mingguang ;
Chan, Yiong-Huak ;
Lavanya, Raghavan ;
Wong, Tien Yin ;
Aung, Tin .
OPHTHALMOLOGY, 2010, 117 (10) :1967-1973
[10]  
PAVLIN CJ, 1991, OPHTHALMOLOGY, V98, P287