Electrochemical synthesis of Ag nanoparticles supported on glassy carbon electrode by means of p-isopropyl calix[6]arene matrix and its application for electrocatalytic reduction of H2O2

被引:73
作者
Raoof, Jahan Bakhsh [1 ]
Ojani, Reza [1 ]
Hasheminejad, Ehteram [1 ]
Rashid-Nadimi, Sahar [2 ]
机构
[1] Mazandaran Univ, Electroanalyt Chem Res Lab, Dept Analyt Chem, Fac Chem, Babol Sar 4741695447, Iran
[2] Univ Isfahan, Dept Renewable Energy, Fac Adv Sci & Technol, Esfahan 8174673441, Iran
关键词
Silver nanoparticles; p-Isopropyl calix[6]arene; Hydrogen peroxide; Electrocatalytic reduction; Glassy carbon electrode; HYDROGEN-PEROXIDE; HORSERADISH-PEROXIDASE; SPECTROPHOTOMETRIC DETERMINATION; OPTICAL-FIBER; BIOSENSOR; ENZYME; HEMOGLOBIN; GLUCOSE; SENSOR; FILM;
D O I
10.1016/j.apsusc.2011.10.133
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The silver nanoparticles were prepared on the glassy carbon (GC) electrode, modified with p-iso propyl calix[6]arene, by preconcentration of silver ions in open circuit potential and followed by electrochemical reduction of silver ions. The stepwise fabrication process of Ag nanoparticles was characterized by scanning electron microscopy and electrochemical impedance spectroscopy. The prepared Ag nanoparticles were deposited with an average size of 70 nm and a homogeneous distribution on the surface of electrode. The observed results indicated that the presence of calixarene layer on the electrode surface can control the particle size and prevent the agglomeratione and electrochemical deposition is a promising technique for preparation of nanoparticles due to its easy-to-use procedure and low cost of implementation. Cyclic voltammetry experiments showed that Ag nanoparticles had a good catalytic ability for the reduction of hydrogen peroxide (H2O2). The effects of p-isopropyl calix[6]arene concentration, applied potential for reduction of Ag+, number of calixarene layers and pH value on the electrocatalytic ability of Ag nanoparticles were investigated. The present modified electrode exhibited a linear range from 5.0 x 10 (5) to 6.5 x 10 (3) M and a detection limit 2.7 x 10 (5) M of H2O2 (S/N = 3) using amperometric method. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:2788 / 2795
页数:8
相关论文
共 55 条
[1]   FLOW SPECTROPHOTOMETRIC METHOD FOR DETERMINATION OF HYDROGEN-PEROXIDE USING A CATION-EXCHANGER FOR PRECONCENTRATION [J].
ALMUAIBED, AM ;
TOWNSHEND, A .
ANALYTICA CHIMICA ACTA, 1994, 295 (1-2) :159-163
[2]   Metal-enhanced fluorescence: an emerging tool in biotechnology [J].
Aslan, K ;
Gryczynski, I ;
Malicka, J ;
Matveeva, E ;
Lakowicz, JR ;
Geddes, CD .
CURRENT OPINION IN BIOTECHNOLOGY, 2005, 16 (01) :55-62
[3]   Amperometric third-generation hydrogen peroxide biosensor based on the immobilization of hemoglobin on multiwall carbon nanotubes and gold colloidal nanoparticles [J].
Chen, Shihong ;
Yuan, Ruo ;
Chai, Yaqin ;
Zhang, Lingyan ;
Wang, Na ;
Li, Xuelian .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (07) :1268-1274
[4]   Two- and three-dimensional Au nanoparticle/CoTMPyP self-assembled nanotructured materials: Film structure, tunable electrocatalytic activity, and plasmonic properties [J].
Cheng, WL ;
Dong, SJ ;
Wang, EK .
JOURNAL OF PHYSICAL CHEMISTRY B, 2004, 108 (50) :19146-19154
[5]   An alkaline direct borohydride fuel cell with hydrogen peroxide as oxidant [J].
Choudhury, NA ;
Raman, RK ;
Sampath, S ;
Shukla, AK .
JOURNAL OF POWER SOURCES, 2005, 143 (1-2) :1-8
[6]   A rapid and easy procedure of biosensor fabrication by microencapsulation of enzyme in hydrophilic synthetic latex films. Application to the amperometric determination of glucose [J].
Cosnier, S ;
Szunerits, S ;
Marks, RS ;
Novoa, A ;
Puech, L ;
Perez, E ;
Rico-Lattes, I .
ELECTROCHEMISTRY COMMUNICATIONS, 2000, 2 (12) :851-855
[7]  
Díaz AN, 1998, ANAL CHIM ACTA, V363, P221
[8]   Peroxide analysis in laundry detergents using liquid chromatography [J].
Effkemann, S ;
Pinkernell, U ;
Karst, U .
ANALYTICA CHIMICA ACTA, 1998, 363 (01) :97-103
[9]   INVESTIGATION OF ELECTRODE REACTIONS BY THE METHOD OF CHARGING-CURVES AND WITH THE AID OF ALTERNATING CURRENTS [J].
ERSHLER, B .
DISCUSSIONS OF THE FARADAY SOCIETY, 1947, 1 :269-277
[10]   Detection of hydrogen peroxide at mesoporous platinum microelectrodes [J].
Evans, SAG ;
Elliott, JM ;
Andrews, LM ;
Bartlett, PN ;
Doyle, PJ ;
Denuault, G .
ANALYTICAL CHEMISTRY, 2002, 74 (06) :1322-1326