Filtration efficiency of surgical and FFP3 masks against composite dust

被引:8
作者
Breul, Sebastian [1 ]
Van Landuyt, Kirsten L. [2 ,3 ]
Reichl, Franz X. [1 ]
Hoegg, Christof [1 ]
Hoet, Peter [4 ]
Godderis, Lode [4 ,5 ]
Van Meerbeek, Bart [2 ,3 ]
Cokic, Stevan M. [2 ,3 ]
机构
[1] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Conservat Dent & Periodontol, Munich, Germany
[2] Univ Leuven, KU Leuven, Dept Oral Hlth Sci, BIOMAT, Leuven, Belgium
[3] Univ Leuven, KU Leuven, UZ Leuven, Univ Hosp Leuven,Dent, Leuven, Belgium
[4] Univ Leuven, KU Leuven, Dept Publ Hlth & Primary Care, Ctr Environm & Hlth, Leuven, Belgium
[5] IDEWE, External Serv Prevent & Protect Work, Heverlee, Belgium
关键词
composite dust; dental (surgical) mask; FFP3; respirator; Nanoparticle; transmission electron microscopy (TEM); NANOPARTICLES; PERFORMANCE; PENETRATION; RESPIRATOR; INHALATION; PARTICLES; EXPOSURE; RELEASE;
D O I
10.1111/eos.12697
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to investigate the protection efficiency of two types of face masks against composite dust and to characterize the particles that penetrated through the masks. Composite dust was created by grinding a commercial nano-filled composite in a plexiglass box without using water cooling or high vacuum evacuation, in order to obtain a worst-case exposure. Dust particles were collected using a personal inhalable aerosol sampler (IOM) fixed inside a custom-made phantom head. Surgical and filtering facepiece (FFP3) masks were tested, and the situation without a mask served as control. The IOM sampler contained a cassette with two filters to collect large inhalable (4-100 mu m) and respirable dust particles (mu m). The amount of particles was determined gravimetrically by weighing filters before and after composite grinding, and further characterized by electron microscopy. Particle collection for both inhalable and respirable dust was the highest when no mask was used, and the lowest with the use of a FFP3 mask. Different sizes and shapes of particles were observed, with the largest particles (>1 mu m) being seen when no mask was applied, whereas only nanoparticles could be detected when either type of face mask was applied. Even though FFP3 masks showed a higher filtration efficacy than surgical masks of the inhalable dust fraction, penetration of a small respirable particle fraction was inevitable for both masks.
引用
收藏
页码:233 / 240
页数:8
相关论文
共 39 条
[1]  
[Anonymous], 2003, Guidance for Industry: Q1A(R2) Stability Testing of New Drug Substances and Products, P1
[2]  
[Anonymous], 1996, J AM DENT ASSOC, V127, P672, DOI DOI 10.14219/JADA.ARCHIVE.1996.0280
[3]  
[Anonymous], 2003, 151482002 ISO
[4]   Conceptual limitations and extensions of lung-deposited Nanoparticle Surface Area Monitor (NSAM) [J].
Asbach, C. ;
Fissan, H. ;
Stahlmecke, B. ;
Kuhlbusch, T. A. J. ;
Pui, D. Y. H. .
JOURNAL OF NANOPARTICLE RESEARCH, 2009, 11 (01) :101-109
[5]   Nanoparticles: a review of particle toxicology following inhalation exposure [J].
Bakand, Shahnaz ;
Hayes, Amanda ;
Dechsakulthorn, Finance .
INHALATION TOXICOLOGY, 2012, 24 (02) :125-135
[6]   Manikin-based performance evaluation of N95 filtering-facepiece respirators challenged with nanoparticles [J].
Balazy, A ;
Toivola, M ;
Reponen, T ;
Podgo,rski, A ;
Zimmer, A ;
Grinshpun, SA .
ANNALS OF OCCUPATIONAL HYGIENE, 2006, 50 (03) :259-269
[7]  
Belkin Nathan L, 2006, AORN J, V84, P655, DOI 10.1016/S0001-2092(06)63946-X
[8]  
Bhuvaneswari P., 2014, RES J PHARM TECHNOL, V7, P938
[9]   Efficacy of three face masks in preventing inhalation of airborne contaminants in dental practice [J].
Checchi, L ;
Montevecchi, M ;
Moreschi, A ;
Graziosi, F ;
Taddei, P ;
Violante, FS .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2005, 136 (07) :877-882
[10]   Release of monomers from composite dust [J].
Cokic, M. ;
Duca, R. C. ;
Godderis, L. ;
Hoet, P. H. ;
Seo, J. W. ;
Van Meerbeek, B. ;
Van Landuyt, K. L. .
JOURNAL OF DENTISTRY, 2017, 60 :56-62