Visual field of high-pass resolution perimetry in normal subjects

被引:9
作者
Wall, M
Chauhan, B
Frisén, L
House, PH
Brito, C
机构
[1] Univ Iowa, Coll Med, Dept Neurol, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Ophthalmol, Iowa City, IA 52242 USA
[3] Dalhousie Univ, Dept Ophthalmol, Halifax, NS, Canada
[4] Gothenburg Univ, Dept Ophthalmol, S-41124 Gothenburg, Sweden
[5] Royal Perth Hosp, Perth, WA, Australia
[6] Eastern Illinois Univ, Dept Psychol, Charleston, IL 61920 USA
关键词
automated perimetry; perimetry; resolution acuity; visual field;
D O I
10.1097/00061198-200402000-00004
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the properties of the visual field of high-pass resolution perimetry in normal subjects. Methods: Four centers collected normative data for high-pass resolution perimetry. In two of the centers the subjects were stratified by age. One eye was tested per subject using high-pass resolution perimetry (Ophthimus(R)). We tested 640 normal subjects and describe their visual field results by test location. We also analyzed the data by concentric zone, age, and by testing center. Results: The individual test location averages confirmed a reduction in resolution with eccentricity. Resolution thresholds increased with age by 0.025 dB per year (P < 0.001). The mean ring size increased by about 1 dB from age 20 to 70. Among centers there were significant differences in the means and the change in threshold with age (P = 0.009). Conclusion: The normal visual field of high-pass resolution perimetry is characterized by an increase in threshold with eccentricity. We found significant differences among the centers that were likely due to multiple factors including differences in subject selection criteria. Whether such differences occur with other perimetric techniques is unknown.
引用
收藏
页码:15 / 21
页数:7
相关论文
共 25 条
[1]  
Birt CM, 1998, J GLAUCOMA, V7, P111
[2]   THE NORMAL VISUAL-FIELD ON THE HUMPHREY FIELD ANALYZER [J].
BRENTON, RS ;
PHELPS, CD .
OPHTHALMOLOGICA, 1986, 193 (1-2) :56-74
[3]  
CHAUHAN BC, 1991, OPHTHALMOLOGY, V98, P79
[4]  
Chauhan BC, 1999, ARCH OPHTHALMOL-CHIC, V117, P24
[5]  
FRISEN L, 1991, ACTA OPHTHALMOL, V69, P511
[6]   ACUITY PERIMETRY - ESTIMATION OF NEURAL CHANNELS [J].
FRISEN, L .
INTERNATIONAL OPHTHALMOLOGY, 1988, 12 (03) :169-174
[7]   HIGH-PASS RESOLUTION PERIMETRY - CENTRAL-FIELD NEURORETINAL CORRELATES [J].
FRISEN, L .
VISION RESEARCH, 1995, 35 (02) :293-301
[8]   VANISHING OPTOTYPES - NEW TYPE OF ACUITY TEST LETTERS [J].
FRISEN, L .
ARCHIVES OF OPHTHALMOLOGY, 1986, 104 (08) :1194-1198
[9]  
FRISEN L, 1993, ACTA OPHTHALMOL, V71, P320
[10]  
FRISEN L, 1987, OPHTHALMOLOGY, V94, P1104