Non-parametric method for separating domestic hot water heating spikes and space heating

被引:25
作者
Bacher, Peder [1 ]
de Saint-Aubain, Philip Anton [1 ]
Christiansen, Lasse Engbo [1 ]
Madsen, Henrik [1 ]
机构
[1] Tech Univ Denmark, DTU Compute, Bldg 303B, DK-2800 Lyngby, Denmark
关键词
Separation of total heat load; Kernel smoother; Robust estimation; Statistical modeling; Time series analyses; Smart grid; Smart metering; Heat metering; CONSUMPTION; MODEL;
D O I
10.1016/j.enbuild.2016.08.037
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper a method for separating spikes from a noisy data series, where the data change and evolve over time, is presented. The method is applied on measurements of the total heat load for a single family house. It relies on the fact that the domestic hot water heating is a process generating short-lived spikes in the time series, while the space heating changes in slower patterns during the day dependent on the climate and user behavior. The challenge is to separate the domestic hot water heating spikes from the space heating without affecting the natural noise in the space heating measurements. The assumption behind the developed method is that the space heating can be estimated by a non-parametric kernel smoother, such that every value significantly above this kernel smoother estimate is identified as a domestic hot water heating spike. First, it is showed how a basic kernel smoothing approach is too simple to deliver reliable results. Therefore the problem is generalized to a local least squares problem, which makes it possible to design a robust kernel smoother, which estimate is not affected by the spikes. Furthermore, the generalized model makes it possible to estimate higher order local polynomials. Finally, the results are evaluated and it is found that the method is capable of calculating a reliable separation of the total heat load into the two components. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:107 / 112
页数:6
相关论文
共 21 条
[1]  
Andersen P. D., 2013, ENERGY BUILD
[2]   Short-term heat load forecasting for single family houses [J].
Bacher, Peder ;
Madsen, Henrik ;
Nielsen, Henrik Aalborg ;
Perers, Bengt .
ENERGY AND BUILDINGS, 2013, 65 :101-112
[3]   STATISTICAL-METHOD FOR DETECTION OF HORMONE SECRETORY SPIKES [J].
CHRISTIAN, LE ;
EVERSON, DO ;
DAVIS, SL .
JOURNAL OF ANIMAL SCIENCE, 1978, 46 (03) :699-706
[4]   NON-PARAMETRIC ESTIMATION OF A MULTIVARIATE PROBABILITY DENSITY [J].
EPANECHN.VA .
THEORY OF PROBILITY AND ITS APPLICATIONS,USSR, 1969, 14 (01) :153-&
[5]   Using a pattern recognition approach to disaggregate the total electricity consumption in a house into the major end-uses [J].
Farinaccio, L ;
Zmeureanu, R .
ENERGY AND BUILDINGS, 1999, 30 (03) :245-259
[6]   Model predictive control for a smart solar tank based on weather and consumption forecasts [J].
Halvgaard, Rasmus ;
Bacher, Peder ;
Perers, Bengt ;
Andersen, Elsa ;
Furbo, Simon ;
Jorgensen, John B. ;
Poulsen, Niels K. ;
Madsen, Henrik .
1ST INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY (SHC 2012), 2012, 30 :270-278
[7]   NONINTRUSIVE APPLIANCE LOAD MONITORING [J].
HART, GW .
PROCEEDINGS OF THE IEEE, 1992, 80 (12) :1870-1891
[8]  
Hastie T., 2009, The Elements of Statistical Learning: Data Mining, Inference, and Prediction, P9
[9]  
Huber P.J., 2003, ROBUST STAT
[10]   Identification of the main thermal characteristics of building components using MATLAB [J].
Jimenez, M. J. ;
Madsen, H. ;
Andersen, K. K. .
BUILDING AND ENVIRONMENT, 2008, 43 (02) :170-180