Corrosion at the head-neck interface of current designs of modular femoral components ESSENTIAL QUESTIONS AND ANSWERS RELATING TO CORROSION IN MODULAR HEAD-NECK JUNCTIONS

被引:78
作者
Osman, K. [1 ,2 ]
Panagiotidou, A. P. [1 ,3 ]
Khan, M. [1 ,5 ]
Blunn, G. [1 ,3 ,4 ]
Haddad, F. S. [1 ]
机构
[1] Univ Coll London Hosp, Inst Sport Exercise & Hlth, London, England
[2] UCL, John Scales Ctr Biomed Engn, 170 Tottenham Court Rd, London W1T 7HA, England
[3] UCL, John Scales Ctr Biomed Engn, Inst Orthopaed & Musculoskeletal Sci, Div Surg & Intervent Sci, 170 Tottenham Court Rd, London W1T 7HA, England
[4] Royal Natl Orthopaed Hosp, Brockley Hill, Stanmore HA7 4LP, Middx, England
[5] UCL, Inst Sports Exercise & Hlth, 170 Tottenham Court Rd, London W1T 7HA, England
关键词
TOTAL HIP-ARTHROPLASTY; ON-METAL BEARINGS; FRETTING CORROSION; TAPER INTERFACE; SURFACE-TOPOGRAPHY; CREVICE CORROSION; ION LEVELS; IN-VITRO; REPLACEMENT; WEAR;
D O I
10.1302/0301-620X.98B5.35592
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
There is increasing global awareness of adverse reactions to metal debris and elevated serum metal ion concentrations following the use of second generation metal-on-metal total hip arthroplasties. The high incidence of these complications can be largely attributed to corrosion at the head-neck interface. Severe corrosion of the taper is identified most commonly in association with larger diameter femoral heads. However, there is emerging evidence of varying levels of corrosion observed in retrieved components with smaller diameter femoral heads. This same mechanism of galvanic and mechanically-assisted crevice corrosion has been observed in metal-on-polyethylene and ceramic components, suggesting an inherent biomechanical problem with current designs of the head-neck interface. We provide a review of the fundamental questions and answers clinicians and researchers must understand regarding corrosion of the taper, and its relevance to current orthopaedic practice.
引用
收藏
页码:579 / 584
页数:6
相关论文
共 55 条
[1]   Influence of cup orientation on the wear performance of metal-on-metal hip replacements [J].
Angadji, A. ;
Royle, M. ;
Collins, S. N. ;
Shelton, J. C. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2009, 223 (H4) :449-457
[2]   How Have New Bearing Surfaces Altered the Local Biological Reactions to Byproducts of Wear and Modularity? [J].
Bauer, Thomas W. ;
Campbell, Patricia A. ;
Hallerberg, Gretchen .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (12) :3687-3698
[3]   Wear patterns of taper connections in retrieved large diameter metal-on-metal bearings [J].
Bishop, Nicholas ;
Witt, Florian ;
Pourzal, Robin ;
Fischer, Alfons ;
Ruetschi, Marcel ;
Michel, Markus ;
Morlock, Michael .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2013, 31 (07) :1116-1122
[4]   High failure rates with a large-diameter hybrid metal-on-metal total hip replacement CLINICAL, RADIOLOGICAL AND RETRIEVAL ANALYSIS [J].
Bolland, B. J. R. F. ;
Culliford, D. J. ;
Langton, D. J. ;
Millington, J. P. S. ;
Arden, N. K. ;
Latham, J. M. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (05) :608-615
[5]   FRETTING CORROSION ACCELERATES CREVICE CORROSION OF MODULAR HIP TAPERS [J].
BROWN, SA ;
FLEMMING, CAC ;
KAWALEC, JS ;
PLACKO, HE ;
VASSAUX, C ;
MERRITT, K ;
PAYER, JH ;
KRAAY, MJ .
JOURNAL OF APPLIED BIOMATERIALS, 1995, 6 (01) :19-26
[6]   Clinically significant corrosion at the head-neck taper interface in total hip arthroplasty: a systematic review and case series [J].
Carli, Alberto ;
Politis, Angelos ;
Zukor, David ;
Huk, Olga ;
Antoniou, John .
HIP INTERNATIONAL, 2015, 25 (01) :7-14
[7]  
COLLIER JP, 1991, CLIN ORTHOP RELAT R, P305
[8]   CORROSION BETWEEN THE COMPONENTS OF MODULAR FEMORAL HIP PROSTHESES [J].
COLLIER, JP ;
SURPRENANT, VA ;
JENSEN, RE ;
MAYOR, MB ;
SURPRENANT, HP .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (04) :511-517
[9]   Corrosion at the Head-Neck Taper as a Cause for Adverse Local Tissue Reactions After Total Hip Arthroplasty [J].
Cooper, H. John ;
Della Valle, Craig J. ;
Berger, Richard A. ;
Tetreault, Matthew ;
Paprosky, Wayne G. ;
Sporer, Scott M. ;
Jacobs, Joshua J. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (18) :1655-1661
[10]   Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement [J].
De Haan, R. ;
Pattyn, C. ;
Gill, H. S. ;
Murray, D. W. ;
Campbell, P. A. ;
De Smet, K. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (10) :1291-1297