Associations of Cognitive Function Scores with Carbon Dioxide, Ventilation, and Volatile Organic Compound Exposures in Office Workers: A Controlled Exposure Study of Green and Conventional Office Environments

被引:513
作者
Allen, Joseph G. [1 ]
MacNaughton, Piers [1 ]
Satish, Usha [2 ]
Santanam, Suresh [3 ]
Vallarino, Jose [1 ]
Spengler, John D. [1 ]
机构
[1] Harvard Univ, TH Chan Sch Publ Hlth, Dept Environm Hlth, Exposure Epidemiol & Risk Program, 401 Pk Dr,404-L, Boston, MA 02215 USA
[2] SUNY Upstate Med Sch, Psychiat & Behav Sci, Syracuse, NY USA
[3] Syracuse Univ, Ctr Excellence, Ind Assessment Ctr, Syracuse, NY USA
关键词
PERCEIVED AIR-QUALITY; CO2; CONCENTRATIONS; DECISION-MAKING; INDOOR; SYMPTOMS; RATES; PERFORMANCE; HEALTH; IMPACT; HOMES;
D O I
10.1289/ehp.1510037
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
BACKGROUND: The indoor built environment plays a critical role in our overall well-being because of both the amount of time we spend indoors (similar to 90%) and the ability of buildings to positively or negatively influence our health. The advent of sustainable design or green building strategies reinvigorated questions regarding the specific factors in buildings that lead to optimized conditions for health and productivity. OBJECTIVE: We simulated indoor environmental quality (IEQ) conditions in "Green" and "Conventional" buildings and evaluated the impacts on an objective measure of human performance: higher-order cognitive function. METHODS: Twenty-four participants spent 6 full work days (0900-1700 hours) in an environmentally controlled office space, blinded to test conditions. On different days, they were exposed to IEQ conditions representative of Conventional [high concentrations of volatile organic compounds (VOCs)] and Green (low concentrations of VOCs) office buildings in the United States. Additional conditions simulated a Green building with a high outdoor air ventilation rate (labeled Green+) and artificially elevated carbon dioxide (CO2) levels independent of ventilation. RESULTS: On average, cognitive scores were 61% higher on the Green building day and 101% higher on the two Green+ building days than on the Conventional building day (p < 0.0001). VOCs and CO2 were independently associated with cognitive scores. CONCLUSIONS: Cognitive function scores were significantly better under Green+ building conditions than in the Conventional building conditions for all nine functional domains. These findings have wide-ranging implications because this study was designed to reflect conditions that are commonly encountered every day in many indoor environments.
引用
收藏
页码:805 / 812
页数:8
相关论文
共 40 条
[1]  
ACGIH (American Conference of Governmental Industrial Hygienists), 2015, 2015 GUID OCC EXP VA
[2]   Green Buildings and Health [J].
Allen J.G. ;
MacNaughton P. ;
Laurent J.G.C. ;
Flanigan S.S. ;
Eitland E.S. ;
Spengler J.D. .
Current Environmental Health Reports, 2015, 2 (3) :250-258
[3]   Elevated corrosion rates and hydrogen sulfide in homes with 'Chinese Drywall' [J].
Allen, Joseph G. ;
MacIntosh, David L. ;
Saltzman, Lori E. ;
Baker, Brian J. ;
Matheson, Joanna M. ;
Recht, Joel R. ;
Minegishi, Taeko ;
Fragala, Matt A. ;
Myatt, Theodore A. ;
Spengler, John D. ;
Stewart, James H. ;
McCarthy, John F. .
SCIENCE OF THE TOTAL ENVIRONMENT, 2012, 426 :113-119
[4]  
[Anonymous], 2013, 2013 ASHRAE Handbook: Fundamentals
[5]  
[Anonymous], MODELING MANAGING SE
[6]  
ASHRAE, 2013, ANSI/ASHRAE Standard 62.1-2013
[7]   Association between ventilation rates in 390 Swedish homes and allergic symptoms in children [J].
Bornehag, CG ;
Sundell, J ;
Hägerhed-Engman, L ;
Sigsgaard, T .
INDOOR AIR, 2005, 15 (04) :275-280
[8]  
Chan WR, 2003, 53367 LAW BERK NATL
[9]   Indoor Air Quality in Green Vs Conventional Multifamily Low-Income Housing [J].
Colton, Meryl D. ;
MacNaughton, Piers ;
Vallarino, Jose ;
Kane, John ;
Bennett-Fripp, Mae ;
Spengler, John D. ;
Adamkiewicz, Gary .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2014, 48 (14) :7833-7841
[10]  
Corsi RL, 2002, INDOOR AIR 2002, P74