Flow rate estimation in large depth-of-field micro-PIV

被引:48
作者
Kloosterman, A. [1 ]
Poelma, C. [1 ]
Westerweel, J. [1 ]
机构
[1] Delft Univ Technol, Proc & Energy Dept, Fac Mech Maritime & Mat Engn, Lab Aero & Hydrodynam, NL-2628 CD Delft, Netherlands
关键词
PARTICLE IMAGE VELOCIMETRY; BLOOD-FLOW; HEART;
D O I
10.1007/s00348-010-1015-9
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
In micro-Particle Image Velocimetry, the requirement of a large field-of-view often results in a large depth-of-correlation, i.e. large depth of the measurement volume. When the velocity varies substantially over the depth-of-correlation, special attention should be paid to a correct interpretation of the measured velocities. When a specialized microscope is needed to meet the requirements of a setup, the resulting more complex optical arrangements can have additional effects on the measurement results. In order to determine flow parameters such as the flow rate, it is sufficient to have a robust estimate of the maximum velocity when the flow is Poiseuille flow. In this paper, an interpretation of the results from particle image velocimetry measurements with low magnification in a round capillary is given for two types of microscopes: a conventional and a specialized microscope. The measured velocity appears to be lower than the maximum velocity, yet is still above the average velocity. The interpretation of the measured velocity differs for the two types of microscopes. The under-estimation of the maximum velocity obtained from the conventional microscope remains small (within 6%) for low-magnification measurements, while the under-estimation of the maximum velocity obtained from the specialized microscope increases up to 25% for a large depth-of-correlation. The images of the in- and out-of-focus particles turn out to play a crucial role in this difference between the two microscopes. Validation of the optical properties of a microscope is important, especially for specialized microscopes where particle images deviate substantially from the existing theory, and this theory is also used to derive the analytical expression for the depth-of-correlation. A procedure is recommended to obtain a correct interpretation of the measured velocity. This procedure is generally applicable, but mainly of importance for specialized microscopes.
引用
收藏
页码:1587 / 1599
页数:13
相关论文
共 19 条
[1]  
Adrian R. J., 2010, Particle Image Velocimetry
[2]  
ADRIAN RJ, 1983, APPL OPTICS, V24, P42
[3]   The depth of correlation in micro-PIV for high numerical aperture and immersion objectives [J].
Bourdon, Christopher J. ;
Olsen, Michael G. ;
Gorby, Allen D. .
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (04) :883-886
[4]   Validation of an analytical solution for depth of correlation in microscopic particle image velocimetry [J].
Bourdon, CJ ;
Olsen, MG ;
Gorby, AD .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2004, 15 (02) :318-327
[5]   Power-filter technique for modifying depth of correlation in microPIV experiments [J].
Bourdon, CJ ;
Olsen, MG ;
Gorby, AD .
EXPERIMENTS IN FLUIDS, 2004, 37 (02) :263-271
[6]   Three-dimensional synchrotron x-ray particle image velocimetry [J].
Fouras, A. ;
Dusting, J. ;
Lewis, R. ;
Hourigan, K. .
JOURNAL OF APPLIED PHYSICS, 2007, 102 (06)
[7]   Volumetric correlation PIV: a new technique for 3D velocity vector field measurement [J].
Fouras, Andreas ;
Lo Jacono, David ;
Nguyen, Chuong Vinh ;
Hourigan, Kerry .
EXPERIMENTS IN FLUIDS, 2009, 47 (4-5) :569-577
[8]   Micro-PIV measurements of blood flow in extraembryonic blood vessels of chicken embryos [J].
Lee, Jung Yeop ;
Ji, Ho Seong ;
Lee, Sang Joon .
PHYSIOLOGICAL MEASUREMENT, 2007, 28 (10) :1149-1162
[9]   The theory of diffraction-limited resolution in microparticle image velocimetry [J].
Meinhart, CD ;
Wereley, ST .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2003, 14 (07) :1047-1053
[10]   A PIV algorithm for estimating time-averaged velocity fields [J].
Meinhart, CD ;
Wereley, ST ;
Santiago, JG .
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2000, 122 (02) :285-289