Transient three-dimensional CFD modelling of ceiling fans

被引:53
作者
Babich, Francesco [1 ]
Cook, Malcolm [1 ]
Loveday, Dennis [1 ]
Rawal, Rajan [2 ]
Shukla, Yash [2 ]
机构
[1] Loughborough Univ, Sch Civil & Bldg Engn, Loughborough, Leics, England
[2] CEPT Univ, Ahmadabad, Gujarat, India
基金
英国工程与自然科学研究理事会;
关键词
Ceiling fan; Thermal comfort; CFD validation; Turbulence modelling; India; Environmental chamber; TURBULENCE MODELS; THERMAL COMFORT; HUMAN THERMOREGULATION; INDOOR ENVIRONMENT; WIDE-RANGE; PERFORMANCE; PREDICTION; NUMBER;
D O I
10.1016/j.buildenv.2017.06.039
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Ceiling fans have been used for decades as a means of providing thermal comfort in tropical countries such as India. However, recent years have witnessed a significant increase in the use of air conditioning as a means to achieve comfort, and therefore in the total energy consumption and related CO2 emissions. Ceiling fans are still viable options to limit use of air conditioners or in combination with air conditioners without compromising on thermal comfort and still achieving energy savings. Ceiling fans generate non-uniform velocity profiles, and therefore relatively non-uniform thermal environments, whose characteristics may be tough to analyse with simple modelling methods. This issue can be investigated using CFD. However, to date, there are few works on ceiling fans, CFD and thermal comfort. More accurate models are therefore required to predict their performance. The research presented in this paper aimed to develop and validate a three-dimensional transient implicit CFD model of a typical ceiling fan available in India by comparing simulation results obtained using different URANS turbulence models with measured data collected in controlled environment. The results highlight that this ceiling fan model is able to replicate the predominant characteristics of the air flow generated by the fan such as the meandering plume and the local fine free shear layers. The best results are achieved when the SST k-omega turbulence model is used, with 83% of the simulated values being within the error bars of the respective measured value. (C) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:37 / 49
页数:13
相关论文
共 45 条
[1]   Effect of Number of Blades on Performance of Ceiling Fans [J].
Adeeb, Ehsan ;
Maqsood, Adnan ;
Mushtaq, Ammar .
2015 THE 4TH INTERNATIONAL CONFERENCE ON ADVANCES IN MECHANICS ENGINEERING (ICAME 2015), 2015, 28
[2]  
[Anonymous], 2004, P ASME HEAT TRANSF F, DOI DOI 10.1115/HT-FED2004-56226
[3]  
[Anonymous], 1971, MATH MODEL PHYSL TEM
[4]  
[Anonymous], 2013, ASHRAE
[5]  
ANSYS, 2015, CFX SOLV MOD GUID
[6]  
Babich Francesco, 2016, P BUILDING SIMULATIO
[7]   Studying the features of air flow induced by a room ceiling-fan [J].
Bassiouny, Ramadan ;
Korah, Nader S. .
ENERGY AND BUILDINGS, 2011, 43 (08) :1913-1918
[8]  
BEE, 2016, TOP 10 CELL FANS IND
[9]   Evolving opportunities for providing thermal comfort [J].
Brager, Gail ;
Zhang, Hui ;
Arens, Edward .
BUILDING RESEARCH AND INFORMATION, 2015, 43 (03) :274-287
[10]  
Brager GS, 2000, ASHRAE J, V42, P21