A 3-D Micromechanical Multi-Loop Magnetometer Driven Off-Resonance by an On-Chip Resonator

被引:22
作者
Laghi, Giacomo [1 ]
Marra, Cristiano R. [1 ]
Minotti, Paolo [1 ]
Tocchio, Alessandro [2 ]
Langfelder, Giacomo [1 ]
机构
[1] Politecn Milan, Dipartimento Elettron Informaz & Bioingn, I-20133 Milan, Italy
[2] STMicroelectronics, Analog MEMS & Sensors Div, I-20010 Milan, Italy
关键词
Microelectromechanical systems (MEMS) sensors; magnetometers; acceleration rejection; vibrations; navigation; FORCE MAGNETIC SENSOR; QUALITY FACTOR; MEMS; ACCELEROMETER; SENSITIVITY; OPERATION;
D O I
10.1109/JMEMS.2016.2563180
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents the principle and complete characterization of a single-chip unit formed by microelectromechanical system magnetometers to sense the 3-D magnetic field vector and a Tang resonator. The three sensors, nominally with the same resonance frequency, are operated 200-Hz off-resonance through an ac current whose reference frequency is provided by the resonator embedded in an oscillating circuit. The sensors gain is increased by adopting a current recirculation strategy using metal strips directly deposited on the structural polysilicon. At a driving value of 100 mu Arms flowing in series through the three devices, the magnetometers show a sub-185 nT/v Hz resolution with a selectable bandwidth up to 50 Hz. Over a +/- 5-mT full-scale range, the sensitivity curves show linearity errors lower than 0.2%, with high cross-axis rejection and immunity to external accelerations. Under temperature changes, the stability of the 200-Hz difference between the magnetometers and the resonator frequency is within 55 ppm/K. Offset is trimmed down to the microtesla range, with an overall measured Allan stability of about 100 nT at 20-s observation time. [2016-0030]
引用
收藏
页码:637 / 651
页数:15
相关论文
共 46 条
[31]   An integrated CMOS micromechanical resonator high-Q oscillator [J].
Nguyen, CTC ;
Howe, RT .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 1999, 34 (04) :440-455
[32]   Practical considerations for the use of a Howland current source for neuro-stimulation [J].
Pouliquen, Philippe ;
Vogelstein, Jacob ;
Etienne-Cummings, Ralph .
2008 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE - INTELLIGENT BIOMEDICAL SYSTEMS (BIOCAS), 2008, :33-+
[33]   A Closed-Loop Digitally Controlled MEMS Gyroscope With Unconstrained Sigma-Delta Force-Feedback [J].
Raman, J. ;
Cretu, E. ;
Rombouts, P. ;
Weyten, L. .
IEEE SENSORS JOURNAL, 2009, 9 (03) :297-305
[34]   A 104-dB dynamic range transimpedance-based CMOS ASIC for tuning fork microgyroscopes [J].
Sharma, Ajit ;
Zaman, Mohammad Faisal ;
Ayazi, Farrokh .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2007, 42 (08) :1790-1802
[35]  
Simon B R, 2012, P IEEE SENSORS, V3, P1
[36]  
Sonmezoglu S, 2016, PROC IEEE MICR ELECT, P103, DOI 10.1109/MEMSYS.2016.7421568
[37]  
Tang W. C., 1989, Proceedings: IEEE Micro Electro Mechanical Systems. An Investigation of Micro Structures, Sensors, Actuators, Machines and Robots (IEEE Cat. No.89THO249-3), P53, DOI 10.1109/MEMSYS.1989.77961
[38]   Quadrature-Error Compensation and Corresponding Effects on the Performance of Fully Decoupled MEMS Gyroscopes [J].
Tatar, Erdinc ;
Alper, Said Emre ;
Akin, Tayfun .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2012, 21 (03) :656-667
[39]  
Thompson Matthew J., 2009, 15th International Conference on Solid-State Sensors, Actuators and Microsystems. Transducers 2009, P1194, DOI 10.1109/SENSOR.2009.5285917
[40]   Parametrically Amplified Z-Axis Lorentz Force Magnetometer [J].
Thompson, Matthew J. ;
Horsley, David A. .