Experimental and numerical study on self-sustaining performance of a 30-kW micro gas turbine generator system during startup process

被引:21
作者
Guan, Jin [1 ]
Lv, Xiaojing [2 ]
Spataru, Catalina [3 ]
Weng, Yiwu [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Mech Engn, Key Lab Power Machinery & Engn, Minist Educ, Shanghai 200240, Peoples R China
[2] Shanghai Jiao Tong Univ, China UK Low Carbon Coll, Res Ctr Low Carbon Combust & Engine Syst, Shanghai 201306, Peoples R China
[3] UCL, UCL Energy Inst, Cent House,14 Upper Woburn Pl, London WC1H 0NN, England
关键词
Micro gas turbine; Start-up schedule; Self-sustaining boundary; Fuel consumption area; Experimental validation; Uncertainty analysis; SIMULATION; OPERATION;
D O I
10.1016/j.energy.2021.121468
中图分类号
O414.1 [热力学];
学科分类号
摘要
The safe startup of micro gas turbine (MGT) generator system is the premise of normal operation. The whole start-up process contains motor startup, ignition, speed acceleration, motor switching to gener-ator and power acceleration. Motor switching to generator happens at the self-sustaining state, which is significant to safe start-up process. However, characteristics of MGT generator system at self-sustaining state are hardly to investigate due to the lack of performance maps and complete experiments. Therefore, this work analyzed start-up schedule and presented a theoretical and experimental study on the self-sustaining performance of MGT generator system, based on the self-designed 30 kW MGT generator system built in Jiangjin Turbocharger Plant, China. The self-sustaining speed boundary and fuel con-sumption area is determined from the aspects of safe startup. A novel principle for determining the self-sustaining point (SSP) is proposed. Results show that the self-sustaining state can be achieved only when speed is over 26,750 rpm, and the SSP is determined at the speed of 30,750 rpm based on the proposed principle. Finally, the self-sustaining TIT and natural gas flow are compared with the experimental data, with two relative errors both almost within 4%. This method is instructive to the MGT generator system startup process. (c) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:13
相关论文
共 34 条
[21]   Integration of compressed air energy storage and gas turbine to improve the ramp rate [J].
Kim, Min Jae ;
Kim, Tong Seop .
APPLIED ENERGY, 2019, 247 :363-373
[22]   Program development and simulation of dynamic operation of micro gas turbines [J].
Kim, Min Jae ;
Kim, Jeong Ho ;
Kim, Tong Seop .
APPLIED THERMAL ENGINEERING, 2016, 108 :122-130
[23]   Global energy perspectives to 2060-WEC's World Energy Scenarios 2019 [J].
Kober, T. ;
Schiffer, H-W ;
Densing, M. ;
Panos, E. .
ENERGY STRATEGY REVIEWS, 2020, 31
[24]   Modeling and controller design of a micro gas turbine for power generation [J].
Lin, Ping ;
Du, Xian ;
Shi, Yan ;
Sun, Xi-Ming .
ISA TRANSACTIONS, 2022, 124 :411-426
[25]   Experimental study of biogas combustion and emissions for a micro gas turbine [J].
Liu, Aiguo ;
Yang, Yudong ;
Chen, Lei ;
Zeng, Wen ;
Wang, Chengjun .
FUEL, 2020, 267
[26]   Effect of fuel composition fluctuation on the safety performance of an IT-SOFC/GT hybrid system [J].
Lv, Xiaojing ;
Ding, Xiaoyi ;
Weng, Yiwu .
ENERGY, 2019, 174 :45-53
[27]   A novel dynamic modeling of an industrial gas turbine using condition monitoring data [J].
Mehrpanahi, A. ;
Hamidavi, A. ;
Ghorbanifar, A. .
APPLIED THERMAL ENGINEERING, 2018, 143 :507-520
[28]   Simulation of startup operation of an industrial twin-shaft gas turbine based on geometry and control logic [J].
Mohammadian, Poorya Keshavarz ;
Saidi, Mohammad Hassan .
ENERGY, 2019, 183 :1295-1313
[29]   Access to electricity in the World Energy Council's global energy scenarios: An outlook for developing regions until 2030 [J].
Panos, Evangelos ;
Densing, Martin ;
Volkart, Kathrin .
ENERGY STRATEGY REVIEWS, 2016, 9 :28-49
[30]  
Pritchard D., 2002, BIOMASS COMBUSTION G