Vertebroplasty 10 years clinical and radiological follow-up

被引:12
作者
Franc, J. [1 ,2 ]
Lehmann, P. [2 ]
Saliou, G. [2 ]
Monet, P. [2 ]
Kocheida, E-M [2 ]
Daguet, E. [2 ]
Laurent, A. [2 ]
Legars, D. [2 ]
Deramond, H. [2 ]
机构
[1] Hop Lariboisiere, Serv Neuroradiol, F-75010 Paris, France
[2] Ctr Hosp Univ Amiens, Serv Neuroradiol Diagnost & Intervent, F-80000 Amiens, France
关键词
Percutaneous acrylic vertebroptasty; Cement Fractures Discs; Osteoporosis; Vertebral angioma; VERTEBRAL COMPRESSION FRACTURES; PERCUTANEOUS VERTEBROPLASTY; POSTMENOPAUSAL WOMEN; CEMENT VOLUME; RISK; POLYMETHYLMETHACRYLATE; OSTEOPOROSIS; HEMANGIOMAS; RALOXIFENE; INJECTION;
D O I
10.1016/j.neurad.2009.10.004
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objectives - Ten years follow up of the first patients treated with percutaneous vertebroplasty Patient and methods - Eighteen patients were retrospectively reviewed having undergone vertebroplasty in our centre between 1989 and 1998 Eight were treated for angioma eight for osteoporotic compression and two followed for myeloma They all underwent clinical and radiological evaluation in 2007 (standard X rays CT scan and MRI) These examinations were compared to prior baseline pre and post therapeutic images Results - Radiological characteristic of cement remained unchanged in the tong term and there was no modification of anatomical structures in contact with it Even if the distribution of cement was asymmetrical there was no fracture of the treated vertebras at distance Degene rative changes of discs facing the vertebroplasty were not more pronounced than for distant discs We found no significant signal or density anomaly of disc in contact direct with cement 38 8% of the patients presented new fractures (n = 30) Seventy percent of the fractures were multiple and contiguous In the tong term all patients reported improvement of pain after the procedure Conclusion - In our series we found a good stability of treatment over time This study shows the long term safety of percutaneous acrylic vertebroplasty in particular harmlessness of cement for bone and discs in contact (C) 2010 Elsevier Masson SAS All rights reserved
引用
收藏
页码:211 / 219
页数:9
相关论文
共 45 条
[1]   Current treatment strategies and outcomes in the management of symptomatic vertebral hemangiomas [J].
Acosta, FL ;
Dowd, CF ;
Chin, C ;
Tihan, T ;
Ames, CP ;
Weinstein, PR .
NEUROSURGERY, 2006, 58 (02) :287-295
[2]  
BAIB J, 1999, SPINE, V24, P1521
[3]   Biomechanical explanation of adjacent fractures following vertebroplasty [J].
Baroud, G ;
Heini, P ;
Nemes, J ;
Bohner, M ;
Ferguson, S ;
Steffen, T .
RADIOLOGY, 2003, 229 (02) :606-607
[4]   Adjacent vertebral failure after vertebroplasty - A biomechanical investigation [J].
Berlemann, U ;
Ferguson, SJ ;
Nolte, LP ;
Hein, PF .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (05) :748-752
[5]   Prevalent vertebral deformities predict hip fractures and new vertebral deformities but not wrist fractures [J].
Black, DM ;
Arden, NK ;
Palermo, L ;
Pearson, J ;
Cummings, SR .
JOURNAL OF BONE AND MINERAL RESEARCH, 1999, 14 (05) :821-828
[6]   Vertebroplasty: State of the art [J].
Chiras, J. ;
Barragan-Campos, H. M. ;
Cormier, E. ;
Jean, B. ;
Rose, M. ;
LeJean, L. .
JOURNAL DE RADIOLOGIE, 2007, 88 (09) :1255-1260
[7]  
Cortet B, 1999, J RHEUMATOL, V26, P2222
[8]  
CORTET B, 1994, REV RHUM, V61, P16
[9]  
Cotten A, 1998, RADIOGRAPHICS, V18, P322
[10]   Percutaneous vertebroplasty: State of the art [J].
Cotten, A ;
Boutry, N ;
Cortet, B ;
Assaker, R ;
Demondion, X ;
Leblond, D ;
Chastanet, P ;
Duquesnoy, B ;
Deramond, H .
RADIOGRAPHICS, 1998, 18 (02) :311-320