Effects of injection rates of contrast material on arterial phase hepatic CT

被引:75
作者
Kim, T [1 ]
Murakami, T [1 ]
Takahashi, S [1 ]
Tsuda, K [1 ]
Tomoda, K [1 ]
Narumi, Y [1 ]
Oi, H [1 ]
Nakamura, H [1 ]
机构
[1] Osaka Univ, Sch Med, Dept Radiol, Suita, Osaka 5650871, Japan
关键词
D O I
10.2214/ajr.171.2.9694469
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Our goal was to assess the effects of the IV injection rate of contrast material on arterial phase hepatic CT. SUBJECTS AND METHODS. One hundred patients were randomly divided into four groups of 25 with different injection rates of 90 ml of contrast material: 2, 3, 4, or 5 ml/sec. Single-level serial CT was performed at the level of the middle section of the main portal vein before injection and every 2 sec from 12 sec to 60 sec after injection of contrast material, The enhancement value was calculated as the difference in attenuation value between the unenhanced and contrast-enhanced images for the aorta and liver parenchyma. The duration of the arterial phase was defined as the interval beginning when the enhancement value for the aorta reached 100 H and ending when the value for the liver parenchyma reached 20 H. RESULTS. Faster injection rates increased the maximum enhancement of the aorta. Although faster injection rates decreased the time from injection to the beginning and the end of the arterial phase, faster injection rates did not decrease the duration of the arterial phase itself. CONCLUSION. A faster injection rate increases arterial enhancement of the liver, and the duration of the arterial phase remains the same as that occurring with a slower injection rate, We hypothesize that faster injection rates can provide better results using CT to reveal hypervascular liver tumors.
引用
收藏
页码:429 / 432
页数:4
相关论文
共 19 条
[1]   Hepatocellular carcinoma: Evaluation with biphasic, contrast-enhanced, helical CT [J].
Baron, RL ;
Oliver, JH ;
Dodd, GD ;
Nalesnik, M ;
Holbert, BL ;
Carr, B .
RADIOLOGY, 1996, 199 (02) :505-511
[2]   UNDERSTANDING AND OPTIMIZING USE OF CONTRAST MATERIAL FOR CT OF THE LIVER [J].
BARON, RL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (02) :323-331
[3]   CONTRAST ENHANCEMENT OF HEPATIC-TUMORS IN CT - COMPARISON BETWEEN BOLUS AND INFUSION TECHNIQUES [J].
BURGENER, FA ;
HAMLIN, DJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1983, 140 (02) :291-295
[4]   HEPATIC CT ENHANCEMENT .1. ALTERATIONS IN THE VOLUME OF CONTRAST MATERIAL WITHIN THE SAME PATIENTS [J].
CHAMBERS, TP ;
BARON, RL ;
LUSH, RM .
RADIOLOGY, 1994, 193 (02) :513-517
[5]   HEPATIC HELICAL CT - CONTRAST MATERIAL INJECTION PROTOCOL [J].
FOLEY, WD ;
HOFFMANN, RG ;
QUIROZ, FA ;
KAHN, CE ;
PERRET, RS .
RADIOLOGY, 1994, 192 (02) :367-371
[6]   Effect of rate of contrast medium injection on hepatic enhancement at CT [J].
Garcia, PA ;
Bonaldi, VM ;
Bret, PM ;
Liang, LJ ;
Reinhold, C ;
Atri, M .
RADIOLOGY, 1996, 199 (01) :185-189
[7]   EFFECT OF VARYING RATES OF LOW-OSMOLARITY CONTRAST-MEDIA INJECTION FOR HEPATIC CT - CORRELATION WITH INDOCYANINE GREEN TRANSIT-TIME [J].
HARMON, BH ;
BERLAND, LL ;
LEE, JY .
RADIOLOGY, 1992, 184 (02) :379-382
[8]   DYNAMIC CONTRAST-ENHANCED CT OF THE LIVER - COMPARISON OF CONTRAST-MEDIUM INJECTION RATES AND UNIPHASIC AND BIPHASIC INJECTION PROTOCOLS [J].
HEIKEN, JP ;
BRINK, JA ;
MCCLENNAN, BL ;
SAGEL, SS ;
FORMAN, HP ;
DICROCE, J .
RADIOLOGY, 1993, 187 (02) :327-331
[9]   DYNAMIC INCREMENTAL CT - EFFECT OF VOLUME AND CONCENTRATION OF CONTRAST MATERIAL AND PATIENT WEIGHT ON HEPATIC ENHANCEMENT [J].
HEIKEN, JP ;
BRINK, JA ;
MCCLENNAN, BL ;
SAGEL, SS ;
CROWE, TM ;
GAINES, MV .
RADIOLOGY, 1995, 195 (02) :353-357
[10]   DUAL-PHASE HELICAL CT OF THE LIVER - VALUE OF ARTERIAL PHASE SCANS IN THE DETECTION OF SMALL (LESS-THAN-OR-EQUAL-TO-1.5-CM) MALIGNANT HEPATIC NEOPLASMS [J].
HOLLETT, MD ;
JEFFREY, RB ;
NINOMURCIA, M ;
JORGENSEN, MJ ;
HARRIS, DP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (04) :879-884