Safety of magnetic resonance scanning without monitoring of patients with pacemakers

被引:20
作者
Bertelsen, Litten [1 ]
Petersen, Helen Hogh [1 ]
Philbert, Berit Thornvig [1 ]
Svendsen, Jesper Hastrup [1 ,2 ,3 ]
Thomsen, Carsten [3 ,4 ]
Vejlstrup, Niels [1 ]
机构
[1] Univ Copenhagen, Rigshosp, Dept Cardiol, Heart Ctr, Blegdamsvej 9, DK-2100 Copenhagen, Denmark
[2] Danish Natl Res Fdn Ctr Cardiac Arrhythmia DARC, Copenhagen, Denmark
[3] Univ Copenhagen, Fac Hlth & Med Sci, Dept Clin Med, Copenhagen, Denmark
[4] Univ Copenhagen, Dept Radiol, Rigshosp, Diagnost Ctr, Copenhagen, Denmark
来源
EUROPACE | 2017年 / 19卷 / 05期
关键词
Magnetic resonance imaging; Cardiac pacemaker; Pacemaker safety; Monitoring; IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS; CARDIAC-PACEMAKERS; 1.5; TESLA; DEVICES; MRI; RISKS; LEADS;
D O I
10.1093/europace/euw066
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims The objective of this study was to investigate whether it is safe to perform 1.5-Tesla magnetic resonance imaging (MRI) scans in pacemaker (PM) patients without pulse oximetry or electrocardiogram monitoring and with no special specific absorption rate (SAR) or time limits, provided that the PMs are interrogated and programmed to asynchronous mode prior to the scan. Methods and results This study reports the outcome of 207 MRI scans on PM patients at Rigshospitalet, Copenhagen University Hospital from June 2010 to September 2013. All MRIs were performed with the PMs in asynchronous mode and without additional monitoring. There were no adverse events registered among the PM patients during the study period. The only statistically significant change after MRI scans was a small, but clinically insignificant increase in atrial sense. No occurrences of reprogramming to power-on-reset were registered. Conclusion It is possible to perform MRI scans relatively safely in PM patients without additional monitoring or change in the normal MRI protocol, given that the PM has been assessed and reprogrammed prior to MRI. This is especially important to remember in the acute setting where MRI scans may be delayed when monitoring facilities are unavailable.
引用
收藏
页码:818 / 823
页数:6
相关论文
共 24 条
[1]  
Al-Sabagh Kifah Hekmat, 2010, Ugeskr Laeger, V172, P1740
[2]   Safety of magnetic resonance imaging in patients with permanent pacemakers: a collaborative clinical approach [J].
Boilson, Barry Anthony ;
Wokhlu, Anita ;
Acker, Nancy G. ;
Felmlee, Joel P. ;
Watson, Robert E., Jr. ;
Julsrud, Paul R. ;
Friedman, Paul A. ;
Cha, Yong-Mei ;
Rea, Robert F. ;
Hayes, David L. ;
Shen, Win-Kuang .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2012, 33 (01) :59-67
[3]   MRI in Patients With Pacemakers Overview and Procedural Management [J].
Bovenschulte, Henning ;
Schlueter-Brust, Klaus ;
Liebig, Thomas ;
Erdmann, Erland ;
Eysel, Peer ;
Zobel, Carsten .
DEUTSCHES ARZTEBLATT INTERNATIONAL, 2012, 109 (15) :270-U15
[4]   Cardiac magnetic resonance imaging at 1.5 T in patients with cardiac rhythm devices [J].
Buendia, Francisco ;
Cano, Oscar ;
Miguel Sanchez-Gomez, Juan ;
Igual, Begona ;
Osca, Joaquin ;
Jose Sancho-Tello, Maria ;
Olaguee, Jose ;
Salvador, Antonio .
EUROPACE, 2011, 13 (04) :533-538
[5]   Determining the Risks of Magnetic Resonance Imaging at 1.5 Tesla for Patients With Pacemakers and Implantable Cardioverter Defibrillators [J].
Cohen, Jennifer D. ;
Costa, Heather S. ;
Russo, Robert J. .
AMERICAN JOURNAL OF CARDIOLOGY, 2012, 110 (11) :1631-1636
[6]   Food and drug administration perspective - Magnetic resonance imaging of pacemaker and implantable cardioverter-defibrillator patients [J].
Faris, Owen P. ;
Shein, Mitchell .
CIRCULATION, 2006, 114 (12) :1232-1233
[7]   Trends in Permanent Pacemaker Implantation in the United States From 1993 to 2009 Increasing Complexity of Patients and Procedures [J].
Greenspon, Arnold J. ;
Patel, Jasmine D. ;
Lau, Edmund ;
Ochoa, Jorge A. ;
Frisch, Daniel R. ;
Ho, Reginald T. ;
Pavri, Behzad B. ;
Kurtz, Steven M. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (16) :1540-1545
[8]   Safety and Outcomes of Magnetic Resonance Imaging in Patients with Abandoned Pacemaker and Defibrillator Leads [J].
Higgins, John V. ;
Gard, Joseph J. ;
Sheldon, Seth H. ;
Espinosa, Raul E. ;
Wood, Christopher P. ;
Felmlee, Joel P. ;
Cha, Yong-Mei ;
Asirvatham, Samuel J. ;
Dalzell, Connie ;
Acker, Nancy ;
Watson, Robert E., Jr. ;
Friedman, Paul A. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2014, 37 (10) :1284-1290
[9]   Risks to pacemaker patients undergoing magnetic resonance imaging examinations [J].
Irnich, Werner .
EUROPACE, 2010, 12 (07) :918-920
[10]   Safe magnetic resonance image scanning of the pacemaker patient: current technologies and future directions [J].
Jung, Werner ;
Zvereva, Vlada ;
Hajredini, Bajram ;
Jaeckle, Sebastian .
EUROPACE, 2012, 14 (05) :631-637