Transcultural validation of a French version of the Iowa Satisfaction with Anesthesia Scale (ISAS-F)

被引:0
|
作者
Falempin, Anne-Sophie [1 ]
Pereira, Bruno [2 ]
Gonnu-Levallois, Sophie [1 ]
de Chazeron, Ingrid [3 ]
Dexter, Franklin [4 ]
Bazin, Jean-Etienne [1 ]
Duale, Christian [5 ]
机构
[1] CHU Clermont Ferrand, Med Peri Operatoire, Clermont Ferrand, France
[2] CHU Clermont Ferrand, Direct Rech Clin & Innovat, Clermont Ferrand, France
[3] CHU Clermont Ferrand, Psychiat, Clermont Ferrand, France
[4] Univ Iowa, Dept Anesthesia, Iowa City, IA 52242 USA
[5] CHU Clermont Ferrand, INSERM, Ctr Pharmacol Clin, CIC1405, 58 Rue Montalembert,BP 69, F-63003 Clermont Ferrand 1, France
来源
CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE | 2020年 / 67卷 / 05期
关键词
PATIENT-SATISFACTION; CARE;
D O I
10.1007/s12630-019-01563-w
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Purpose We sought to validate a French translation of the Iowa Satisfaction with Anesthesia Scale (ISAS), a tool to assess the patient's satisfaction with monitored anesthesia care for surgery. The ISAS tool is particularly pertinent as surgery with monitored anesthesia care is increasingly used in ambulatory surgery settings. Methods We studied content validity, internal consistency, convergent validity (vs physician-estimated satisfaction), and test-retest reliability of the French version of the ISAS (ISAS-F) in 122 adult patients undergoing a brief outpatient invasive procedure under conscious sedation. The ISAS-F was answered twice by the patient, once in the postanesthesia care unit and once before discharge from the ambulatory care unit. Results The median [interquartile range (IQR)] time of completion at the first assessment was 2 [2-4] min. The total median [IQR] ISAS-F score was 2.3 [1.8-2.7]. Internal consistency of the ISAS-F was found to be good (Cronbach's alpha = 0.68). Test-retest reliability was significant, with an intra-class correlation coefficient at 0.74 (95% confidence interval [CI], 0.63 to 0.85). The ISAS-F score correlated with the physician-estimated satisfaction score, with an intra-class correlation coefficient of 0.28 (95% CI, 0.12 to 0.44; P = 0.01). Discussion This validated version of the ISAS can now be used by French-speaking researchers and physicians to assess patient satisfaction with the anesthesia technique.
引用
收藏
页码:541 / 549
页数:9
相关论文
共 50 条
  • [1] Transcultural validation of a French version of the Iowa Satisfaction with Anesthesia Scale (ISAS-F); [Validation transculturelle d’une version française de l’échelle de satisfaction par rapport à l’anesthésie de l’Iowa (ISAS-F)]
    Falempin A.-S.
    Pereira B.
    Gonnu-Levallois S.
    de Chazeron I.
    Dexter F.
    Bazin J.-É.
    Dualé C.
    Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2020, 67 (5): : 541 - 549
  • [2] Psychometric properties of Iowa Anesthesia Satisfaction Scale Turkish version
    Ali Özgül Saltalı
    Tuba Çatak
    Ebru Çanakçı
    Irish Journal of Medical Science (1971 -), 2023, 192 : 2357 - 2364
  • [3] Psychometric properties of Iowa Anesthesia Satisfaction Scale Turkish version
    Saltali, Ali Ozgul
    Catak, Tuba
    Canakci, Ebru
    IRISH JOURNAL OF MEDICAL SCIENCE, 2023, 192 (05) : 2357 - 2364
  • [4] Iowa satisfaction with anesthesia scale
    Na, Hyo-Seok
    Song, In-Ae
    Park, Hong-Sik
    Hwang, Jung-Won
    Do, Sang-Hwan
    Kim, Chong-Soo
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2012, 62 (03) : 297 - 297
  • [5] The Transcultural Adaptation and Validation of the Chinese Version of the Duke Anticoagulation Satisfaction Scale
    Wu, Yibo
    Dong, Shujie
    Li, Xinyi
    Xu, Haiping
    Xie, Xiaohui
    FRONTIERS IN PHARMACOLOGY, 2022, 13
  • [6] Iowa Satisfaction with Anesthesia Scale for regional anesthesia
    Dexter, Franklin
    JOURNAL OF CLINICAL ANESTHESIA, 2016, 28 : 81 - 82
  • [7] French validation of a brief version of the Marital Satisfaction Scale
    Baertschi, M.
    Dos Santos, J. Flores Alves
    Tissot, H.
    Canuto, A.
    Favez, N.
    Weber, K.
    EUROPEAN REVIEW OF APPLIED PSYCHOLOGY-REVUE EUROPEENNE DE PSYCHOLOGIE APPLIQUEE, 2017, 67 (04): : 207 - 212
  • [8] K Transcultural Validation of the French Version of the Modified Edmonton Symptom Assessment Scale: The ESAS12-F
    Tricou, Colombe
    Ruer, Murielle
    Nekolaichuk, Cheryl
    Sigurdardottir, Katrin
    Perceau-Chambard, Elise
    Bruera, Eduardo
    Filbet, Marilene
    JOURNAL OF PALLIATIVE MEDICINE, 2019, 22 (12) : 1553 - 1560
  • [9] Use and scoring of the Iowa Satisfaction with Anesthesia Scale
    Dexter, Franklin
    AIN SHAMS JOURNAL OF ANESTHESIOLOGY, 2018, 10
  • [10] Iowa Satisfaction with Anesthesia Scale for general anaesthesia
    Dexter, Franklin
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2014, 31 (01) : 62 - 62