Noninvasive assessment of left main coronary stent patency with 16-slice computed tomography

被引:70
作者
Gilard, M [1 ]
Cornily, JC
Rioufol, G
Finet, G
Pennec, PY
Mansourati, J
Blanc, JJ
Boschat, J
机构
[1] Brest Univ Hosp, La Cavale Blanche Hosp, Dept Cardiol, F-29609 Brest, France
[2] Univ Lyon 1, F-69365 Lyon, France
[3] Cardiovasc Hosp, Dept Hemodynam, F-69365 Lyon, France
关键词
D O I
10.1016/j.amjcard.2004.08.073
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We investigated the ability of 16-slice computer tomography (CT) to discriminate any restenosis after left main coronary artery stenting in 29 consecutive patients., CT was able to detect all stents and analyze the lumen properly in 27 of 29 cases. With the exception of arrhythmic or heavily calcified segments, multislice CT provides a noninvasive alternative to conventional coronary, angiography in the follow-up of left main angioplasty with stenting. (C) 2005 by Excerpta Medica Inc.
引用
收藏
页码:110 / 112
页数:3
相关论文
共 11 条
  • [1] Neointimal hyperplasia in carotid stent detected with multislice computed tomography
    Cademartiri, F
    Mollet, N
    Nieman, K
    Krestin, GP
    de Feyter, PJ
    [J]. CIRCULATION, 2003, 108 (21) : E147 - E147
  • [2] Multislice spiral computed tomography for the detection of coronary stent restenosis and patency
    Krüger, S
    Mahnken, AH
    Sinha, AM
    Borghans, A
    Dedden, K
    Hoffmann, R
    Hanrath, P
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2003, 89 (2-3) : 167 - 172
  • [3] Usefulness of CT angiography with volume rendering after carotid angioplasty and stenting
    Leclerc, X
    Gauvrit, JY
    Pruvo, JP
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (03) : 820 - 822
  • [4] Coronary artery stents in multislice computed tomography -: In vitro artifact evaluation
    Mahnken, AH
    Buecker, A
    Wildberger, JE
    Ruebben, A
    Stanzel, S
    Vogt, F
    Günther, RW
    Blindt, R
    [J]. INVESTIGATIVE RADIOLOGY, 2004, 39 (01) : 27 - 33
  • [5] Coronary angiography with multi-slice computed tomography
    Nieman, K
    Oudkerk, M
    Rensing, BJ
    van Ooijen, P
    Munne, A
    van Geuns, RJ
    de Feyter, PJ
    [J]. LANCET, 2001, 357 (9256) : 599 - 603
  • [6] Long-term (three-year) outcomes after stenting of unprotected left main coronary artery stenosis in patients with normal left ventricular function
    Park, SJ
    Park, SW
    Hong, MK
    Lee, CW
    Lee, JH
    Kim, JJ
    Jang, YS
    Shin, EK
    Yoshida, Y
    Tamura, T
    Kimura, T
    Nobuyoshi, M
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2003, 91 (01) : 12 - 16
  • [7] Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction
    Ropers, D
    Baum, U
    Pohle, K
    Anders, K
    Ulzheimer, S
    Ohnesorge, B
    Schlundt, C
    Bautz, W
    Daniel, WG
    Achenbach, S
    [J]. CIRCULATION, 2003, 107 (05) : 664 - 666
  • [8] Noninvasive detection and evaluation of atherosclerotic coronary plaques with multislice computed tomography
    Schroeder, S
    Kopp, AF
    Baumbach, A
    Meisner, C
    Kuettner, A
    Georg, C
    Ohnesorge, B
    Herdeg, C
    Claussen, CD
    Karsch, KR
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (05) : 1430 - 1435
  • [9] Unprotected left main coronary artery stenting: Immediate and medium-term outcomes of 140 elective procedures
    Silvestri, M
    Barragan, P
    Sainsous, J
    Bayet, G
    Simeoni, LB
    Roquebert, PO
    Macaluso, G
    Bouvier, JL
    Comet, B
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (06) : 1543 - 1550
  • [10] Results and long-term predictors of adverse clinical events after elective percutaneous interventions on unprotected left main coronary artery
    Takagi, T
    Stankovic, G
    Finci, L
    Toutouzas, K
    Chieffo, A
    Spanos, V
    Liistro, F
    Briguori, C
    Corvaja, N
    Albero, R
    Sivieri, G
    Paloschi, R
    Di Mario, C
    Colombo, A
    [J]. CIRCULATION, 2002, 106 (06) : 698 - 702