Evaluation of a treatment planning system developed for clinical boron neutron capture therapy and validation against an independent Monte Carlo dose calculation system

被引:43
作者
Hu, Naonori [1 ,2 ]
Tanaka, Hiroki [2 ]
Kakino, Ryo [1 ]
Yoshikawa, Syuushi [1 ]
Miyao, Mamoru [3 ]
Akita, Kazuhiko [1 ]
Isohashi, Kayako [1 ]
Aihara, Teruhito [1 ]
Nihei, Keiji [1 ,4 ]
Ono, Koji [1 ]
机构
[1] Osaka Med & Pharmaceut Univ, Kansai BNCT Med Ctr, Osaka Fu Takatsuki Shi Daigakumachi 2-7, Takatsuki, Osaka, Japan
[2] Kyoto Univ, Inst Integrated Radiat & Nucl Sci, Kyoto, Japan
[3] Osaka Med & Pharmaceut Univ Hosp, Cent Dept Radiol, Takatsuki, Osaka, Japan
[4] Osaka Med & Pharmaceut Univ Hosp, Dept Radiat Oncol, Takatsuki, Osaka, Japan
关键词
Boron neutron capture therapy; Treatment planning system; Commissioning; Monte Carlo simulation; COMPUTATIONAL DOSIMETRY; VERIFICATION;
D O I
10.1186/s13014-021-01968-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Boron neutron capture therapy (BNCT) for the treatment of unresectable, locally advanced, and recurrent carcinoma of the head and neck cancer has been approved by the Japanese government for reimbursement under the national health insurance as of June 2020. A new treatment planning system for clinical BNCT has been developed by Sumitomo Heavy Industries, Ltd. (Sumitomo), NeuCure (R) Dose Engine(.) To safely implement this system for clinical use, the simulated neutron flux and gamma ray dose rate inside a water phantom was compared against experimental measurements. Furthermore, to validate and verify the new planning system, the dose distribution inside an anthropomorphic head phantom was compared against a BNCT treatment planning system SERA and an in-house developed Monte Carlo dose calculation program. The simulated results closely matched the experimental results, within 5% for the thermal neutron flux and 10% for the gamma ray dose rate. The dose distribution inside the head phantom closely matched with SERA and the in-house developed dose calculation program, within 3% for the tumour and a difference of 0.3 Gy(w) for the brain.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Independent calculation of dose distributions for helical tomotherapy using a conventional treatment planning system
    Klueter, Sebastian
    Schubert, Kai
    Lissner, Steffen
    Sterzing, Florian
    Oetzel, Dieter
    Debus, Juergen
    MEDICAL PHYSICS, 2014, 41 (08) : 130 - 141
  • [32] Evaluation of a commercial electron treatment planning system based on Monte Carlo techniques (eMC)
    Pemler, Peter
    Besserer, Juergen
    Schneider, Uwe
    Neuenschwander, Hans
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2006, 16 (04): : 313 - 329
  • [33] Commissioning of a synchrotron-based proton beam therapy system for use with a Monte Carlo treatment planning system
    Azcona, Juan-Diego
    Aguilar, Borja
    Perales, Alvaro
    Polo, Ramon
    Zucca, Daniel
    Irazola, Leticia
    Vinals, Alberto
    Cabello, Pablo
    Delgado, Jose-Miguel
    Pedrero, Diego
    Bermudez, Rocio
    Fayos-Sola, Roser
    Huesa-Berral, Carlos
    Burguete, Javier
    RADIATION PHYSICS AND CHEMISTRY, 2023, 204
  • [34] Empirical description and Monte Carlo simulation of fast neutron pencil beams as basis of a treatment planning system
    Bourhis-Martin, E
    Meissner, P
    Rassow, J
    Baumhoer, W
    Schmidt, R
    Sauerwein, W
    MEDICAL PHYSICS, 2002, 29 (08) : 1670 - 1677
  • [35] Evaluation of monte carlo to support commissioning of the treatment planning system of new pencil beam scanning proton therapy facilities
    Botnariuc, D.
    Court, S.
    Lourenco, A.
    Gosling, A.
    Royle, G.
    Hussein, M.
    Rompokos, V
    Veiga, C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (04)
  • [36] Impact of Dose Perturbations Around Brachytherapy Seeds in External-Beam Radiotherapy Planning: A Fundamental and Clinical Validation Using Treatment Planning System-Based Monte Carlo Simulations
    Ogawa, Shuta
    Yasui, Keisuke
    Hayashi, Naoki
    Saito, Yasunori
    Hayashi, Shinya
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (10)
  • [37] Verification for dose estimation performance of a Monte-Carlo based treatment planning system in University of Tsukuba
    Kumada, Hiroaki
    Takada, Kenta
    Aihara, Teruhito
    Matsumura, Akira
    Sakurai, Hideyuki
    Sakae, Takeji
    APPLIED RADIATION AND ISOTOPES, 2020, 166
  • [38] Validation of the analytical irradiator model and Monte Carlo dose engine in the small animal irradiation treatment planning system μ-RayStation 8B
    Chiavassa, S.
    Nilsson, R.
    Clement-Colmou, K.
    Potiron, V
    Delpon, G.
    Traneus, E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (03)
  • [39] A virtual-acceterator-based verification of a Monte Carlo dose calculation algorithm for electron beam treatment planning in clinical situations
    Wieslander, Elinore
    Knoos, Tommy
    RADIOTHERAPY AND ONCOLOGY, 2007, 82 (02) : 208 - 217
  • [40] The effect of algorithms on dose distribution in inhomogeneous phantom: Monaco treatment planning system versus monte carlo simulation
    Tugrul, Taylan
    JOURNAL OF MEDICAL PHYSICS, 2021, 46 (02) : 111 - 115