Biomechanical behavior of retrograde intramedullary nails in distal femoral fractures

被引:4
作者
Albareda-Albareda, J. [1 ,2 ,3 ]
Gabarre-Raso, S. [4 ]
Rosell-Pradas, J. [5 ]
Puertolas-Broto, S. [5 ,6 ]
Ibarz-Montaner, E. [5 ,6 ]
Redondo-Trasobares, B. [2 ,3 ]
Gomez-Vallejo, J. [1 ,2 ,3 ]
Blanco-Rubio, N. [1 ,2 ,3 ]
Sanchez-Gimeno, M. [1 ,2 ,3 ]
Herrera-Rodriguez, A. [1 ,2 ,6 ]
Gracia-Villa, L. [5 ,6 ]
机构
[1] Univ Zaragoza, Dept Surg, Zaragoza, Spain
[2] Aragon Hlth Res Inst, Zaragoza, Spain
[3] Lozano Blesa Univ Hosp, Dept Orthopaed Surg & Traumatol, San Juan Bosco 15, Zaragoza 50009, Spain
[4] Vlaams Inst Biotechnol, Leuven, Belgium
[5] Univ Zaragoza, Dept Mech Engn, Zaragoza, Spain
[6] Aragon Inst Engn Res, Zaragoza, Spain
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2021年 / 52卷
关键词
Intramedullary nail; Retrograde reamed nail; Femoral fracture; Osteosynthesis; Finite element analysis; FEMUR FRACTURES; INTERNAL-FIXATION; SHAFT FRACTURES; LOCKING PLATES; BLADE PLATE; LONG-TERM; EPIDEMIOLOGY; DIAPHYSEAL; COMPOSITE; OUTCOMES;
D O I
10.1016/j.injury.2021.01.052
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Fractures of the distal femur affect three different groups of individuals: younger people suffering highenergy trauma, elderly people with fragile bones and people with periprosthetic fractures around previous total knee arthroplasty. Main indications of intramedullary nailing are for supracondylar fractures type A or type C of the AO classification. The main objective of the present work is to analyze, by means of FE simulation, the influence of retrograde nail length, considering different blocking configurations and fracture gaps, on the biomechanical behavior of supracondylar fractures of A type. A three dimensional (3D) finite element model of the femur from 55-year-old male donor was developed, and then a stability analysis was performed for the fixation provided by the retrograde nail at a distal fracture with different fracture gaps: 0.5 mm, 3 mm y 20 mm, respectively. Besides, for each gap, three nail lengths were studied with a general extent (320 mm, 280 mm and 240 mm), considering two transversal screws (M/L) at the distal part and different screw combinations above the fracture. The study was focused on the immediately post-operative stage, without any biological healing process. In view of the obtained results, it has been demonstrated new possibilities of blocking configuration in addition to the usual ones, which allows establishing recommendations for nail design and clinical practice, avoiding excessive stress concentrations both in screws, with the problem of rupture and loss of blocking, and in the contact of nail tip with cortical bone, with the problem of a new stress fracture. (c) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页码:S76 / S86
页数:11
相关论文
共 46 条
[1]   Shear movement at the fracture site delays healing in a diaphyseal fracture model [J].
Augat, P ;
Burger, J ;
Schorlemmer, S ;
Henke, T ;
Peraus, M ;
Claes, L .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2003, 21 (06) :1011-1017
[2]   Biomechanical performance of retrograde nail for supracondylar fractures stabilization [J].
Chantarapanich, Nattapon ;
Sitthiseripratip, Kriskrai ;
Mahaisavariya, Banchong ;
Siribodhi, Pongwit .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2016, 54 (06) :939-952
[3]   Biomechanical analysis of retrograde intramedullary nail fixation in distal femoral fractures [J].
Chen, Shih-Hao ;
Yu, Tzai-Chiu ;
Chang, Chih-Han ;
Lu, Yuan-Chiao .
KNEE, 2008, 15 (05) :384-389
[4]   Finite element comparison of retrograde intramedullary nailing and locking plate fixation with/without an intramedullary allograft for distal femur fracture following total knee arthroplasty [J].
Chen, Shih-Hao ;
Chiang, Ming-Chieh ;
Hung, Ching-Hua ;
Lin, Shang-Chih ;
Chang, Hsiao-Wei .
KNEE, 2014, 21 (01) :224-231
[5]   EFFECT OF DYNAMIZATION ON GAP HEALING OF DIAPHYSEAL FRACTURES UNDER EXTERNAL FIXATION [J].
CLAES, LE ;
WILKE, HJ ;
AUGAT, P ;
RUBENACKER, S ;
MARGEVICIUS, KJ .
CLINICAL BIOMECHANICS, 1995, 10 (05) :227-234
[6]   Epidemiology of adult fractures: A review [J].
Court-Brown, Charles M. ;
Caesar, Ben .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2006, 37 (08) :691-697
[7]   Far Cortical Locking Enables Flexible Fixation With Periarticular Locking Plates [J].
Doornink, Josef ;
Fitzpatrick, Daniel C. ;
Madey, Steven M. ;
Bottlang, Michael .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 :S29-S34
[8]   Type of Hip Fracture Determines Load Share in Intramedullary Osteosynthesis [J].
Eberle, Sebastian ;
Gerber, Claus ;
von Oldenburg, Geert ;
Hungerer, Sven ;
Augat, Peter .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (08) :1972-1980
[9]   Influence of gap size, screw configuration, and nail materials in the stability of anterograde reamed intramedullary nail in femoral transverse fractures [J].
Gabarre, Sergio ;
Albareda, Jorge ;
Gracia, Luis ;
Puertolas, Sergio ;
Ibarz, Elena ;
Herrera, Antonio .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 :S40-S46
[10]   Influence of screw combination and nail materials in the stability of anterograde reamed intramedullary nail in distal femoral fractures [J].
Gabarre, Sergio ;
Albareda, Jorge ;
Gracia, Luis ;
Puertolas, Sergio ;
Ibarz, Elena ;
Herrera, Antonio .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 :S47-S53