Robust frequency risk-constrained unit commitment model for AC-DC system considering wind uncertainty

被引:7
作者
Jiang, Sufan [1 ,2 ]
Wu, Chuanshen [1 ]
Gao, Shan [1 ,2 ]
Pan, Guangsheng [1 ]
Liu, Yu [1 ]
Zhao, Xin [1 ]
Wang, Sicheng [1 ]
机构
[1] Southeast Univ, Sch Elect Engn, Nanjing, Peoples R China
[2] Sipailou 2, Nanjing, Jiangsu, Peoples R China
关键词
Wind uncertainty set formulation; Probability density function; High voltage direct current (HVDC) system; Frequency violation risk factors; Stochastic and robustness-based unit; commitment model; VOLTAGE STABILITY; POWER-SYSTEM; ENERGY; GENERATION; LOAD; OPTIMIZATION; OPERATION;
D O I
10.1016/j.renene.2022.06.017
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
With the increasing penetration of volatile renewable energy sources (RES) in power systems, the formulation of RES uncertainty set in the unit commitment (UC) problem poses significant challenges to the operators especially those in AC-DC systems. To overcome the over-conservativeness and computational redundancy in conventional uncertainty formulation methods, this paper induces the stochastic rationale into the robust dispatch model and proposes a two-stage robust frequency risk-constrained unit commitment (FRCUC) model to excavate the system flexibility. Based on the typical characteristics of AC-DC dispatch system, the frequency violation risk (FVR) factors are proposed to enhance the adaptability of uncertainty sets, wherein the HVDC regulation is activated to cope with the extreme uncertain scenarios with lower probability. As a result, being aware of the wind power distribution, the proposed model succeeds in managing the operational risks by fully exploiting the controllability of HVDC system, and the over-conservativeness from conventional robust model is handled by the proposed FVR factors. The outperformance of our model is validated by the numerical experiments on a modified AC-DC system, it is validated that the operational risks are evaluated when considering the violated wind power distribution, and therefore the model economic benefits are promoted when ensuring the reliability. (c) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页码:395 / 406
页数:12
相关论文
共 38 条
[31]   A Reserve Response Set Model for Systems with Stochastic Resources [J].
Singhal, Nikita G. ;
Li, Nan ;
Hedman, Kory W. .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2018, 33 (04) :4038-4049
[32]   Performance evaluation of grid-connected photovoltaic systems based on two photovoltaic module technologies under tropical climate conditions [J].
Tahri, Fatima ;
Tahri, Ali ;
Oozeki, Takashi .
ENERGY CONVERSION AND MANAGEMENT, 2018, 165 :244-252
[33]   Robust Risk-Constrained Unit Commitment With Large-Scale Wind Generation: An Adjustable Uncertainty Set Approach [J].
Wang, Cheng ;
Liu, Feng ;
Wang, Jianhui ;
Qiu, Feng ;
Wei, Wei ;
Mei, Shengwei ;
Lei, Shunbo .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2017, 32 (01) :723-733
[34]   Risk-Based Admissibility Assessment of Wind Generation Integrated into a Bulk Power System [J].
Wang, Cheng ;
Liu, Feng ;
Wang, Jianhui ;
Wei, Wei ;
Mei, Shengwei .
IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2016, 7 (01) :325-336
[35]   Influence of variability and uncertainty of wind and waves on fatigue damage of a floating wind turbine drivetrain [J].
Wang, Shuaishuai ;
Moan, Torgeir ;
Jiang, Zhiyu .
RENEWABLE ENERGY, 2022, 181 :870-897
[36]   Distributionally robust coordination optimization scheduling for electricity-gas-transportation coupled system considering multiple uncertainties [J].
Zhang, Yachao ;
Liu, Wei ;
Huang, Zhanghao ;
Zheng, Feng ;
Le, Jian ;
Zhu, Shu .
RENEWABLE ENERGY, 2021, 163 :2037-2052
[37]   Data-adaptive robust unit commitment in the hybrid AC/DC power system [J].
Zhou, Bo ;
Ai, Xiaomeng ;
Fang, Jiakun ;
Yao, Wei ;
Zuo, Wenping ;
Chen, Zhe ;
Wen, Jinyu .
APPLIED ENERGY, 2019, 254
[38]   Reliability and economic evaluation of power system with renewables: A review [J].
Zhou, P. ;
Jin, R. Y. ;
Fan, L. W. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 58 :537-547