Experimental analysis of an advanced dynamic glazing prototype integrating PCM and thermotropic layers

被引:50
作者
Goia, Francesco [1 ,2 ]
Bianco, Lorenza [2 ]
Cascone, Ylenia [2 ]
Perino, Marco [2 ]
Serra, Valentina [2 ]
机构
[1] Norwegian Univ Sci & Technol, Res Ctr Zero Emiss Bldg, Fac Architecture & Fine Arts, Alfred Getz Vei 3, N-7491 Trondheim, Norway
[2] Politecn Torino, TEBE Res Grp, Dept Energy, I-10129 Turin, Italy
来源
PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY (SHC 2013) | 2014年 / 48卷
关键词
advanced glazing systems; dynamic building envelope components; PCM; termotropic glass; experimental analysis; SYSTEM; BEHAVIOR;
D O I
10.1016/j.egypro.2014.02.144
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Glazing components are the most challenging element of the building envelope system. The insertion of a Phase Change Material coupled with a thermotropic layer is herewith proposed as an innovative solution aimed at improving the energy performance of the fenestration. The intention is to increase the dynamic features of glazing systems and to enhance their capability of exploiting solar energy - a crucial feature in nearly Zero Energy Buildings. The paper presents the experimental analysis of two prototypes of such a glazing concept and the assessment of their energy performance during the warm season. The samples are installed on an outdoor thermostatic cell facing south, together with a reference triple glazed unit, and continuous measurements of temperatures, irradiances and heat fluxes are performed. In the summer season, when the aim of the glazing system is to reduce the solar gain and to allow daylighting the energy performance is very promising. When compared to the reference technology, both the prototypes are able to reduce to a great extend the direct transmitted solar energy, as well as to smooth the peak indoor surface temperature of the glazing. In particular, one of the two configurations lowers down the solar energy gain under all boundary conditions, while the other configuration presents a slightly worse performance than the other prototype when high solar irradiation occurs. An attempt to measure the thermal transmittance was also carried out and it is shown that the insertion of PCM does not increase the U-value of the component. (C) 2014 The Authors.Published by Elsevier Ltd.
引用
收藏
页码:1272 / 1281
页数:10
相关论文
共 10 条
[2]   Characterization of the optical properties of a PCM glazing system [J].
Goia, Francesco ;
Zinzi, Michele ;
Carnielo, Emiliano ;
Serra, Valentina .
1ST INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY (SHC 2012), 2012, 30 :428-437
[3]   Improving thermal comfort conditions by means of PCM glazing systems [J].
Goia, Francesco ;
Perin, Marco ;
Serra, Valentina .
ENERGY AND BUILDINGS, 2013, 60 :442-452
[4]   A numerical model to evaluate the thermal behaviour of PCM glazing system configurations [J].
Goia, Francesco ;
Perino, Marco ;
Haase, Matthias .
ENERGY AND BUILDINGS, 2012, 54 :141-153
[5]  
Goia M., 2010, P IAQVEC 2010 7 INT, P1
[6]   TIM-PCM external wall system for solar space heating and daylighting [J].
Manz, H ;
Egolf, PW ;
Suter, P ;
Goetzberger, A .
SOLAR ENERGY, 1997, 61 (06) :369-379
[7]   Variable solar control using thermotropic core/shell particles [J].
Muehling, Olaf ;
Seeboth, Arno ;
Haeusler, Tobias ;
Ruhmann, Ralf ;
Potechius, Elvira ;
Vetter, Renate .
SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2009, 93 (09) :1510-1517
[8]   Updated world map of the Koppen-Geiger climate classification [J].
Peel, M. C. ;
Finlayson, B. L. ;
McMahon, T. A. .
HYDROLOGY AND EARTH SYSTEM SCIENCES, 2007, 11 (05) :1633-1644
[9]  
UNI, 1994, 103491994 UNI, P35
[10]   PCM-facade-panel for daylighting and room heating [J].
Weinläder, H ;
Beck, A ;
Fricke, J .
SOLAR ENERGY, 2005, 78 (02) :177-186