Gadolinium-enhanced three-dimensional MR angiography before endovascular treatment of aneurysms in the abdominal aorta, iliac and peripheral vessels

被引:7
作者
Biederer, J
Link, J
Steffens, JC
Fronius, M
Heller, M
机构
[1] Univ Kiel, Radiol Diagnost Klin, D-24105 Kiel, Germany
[2] Univ Regensburg Klinikum, Inst Rontgendiagnost, Regensburg, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2000年 / 172卷 / 12期
关键词
aneurysm; abdominal aorta; peripheral arteries; MRA; DSA;
D O I
10.1055/s-2000-9214
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The value of DSA for the measurement of aortic and peripheral arterial aneurysm dimensions before endovascular treatment is limited by projection effects. It was evaluated if additional gadolinium-enhanced three-dimensional MR angiography (3D-CEMRA) could compensate for the disadvantages of D5A. Materials and Methods: 21 patients with 35 aneurysms in the abdominal aorta (14), iliac (9) and femoropopliteal vessels (12) were assessed with DSA (7 with calibrated catheter, 14 with yardstick) and 3D-CEMRA (TR/TE 7.8/2.1 ms, flip-angle 40 degrees, Matrix 512 x 224, FOV 500 mm, eff. slice 1.8 mm). We measured and compared aneurysm dimensions on both modalities. 3D-CEMRA was regarded as the reference method to evaluate the dimension of DSA-projection effects. Results: Diameter and length of aneurysms were underestimated on DSA with the yardstick as reference. The deviation ranged from 15% (+/-5%) in the aorta to 21% (+/-10%) in the iliac vessels. Only with calibrated catheters as reference (7/21 DSA), were the distances on DSA correlated well with MRA. In 2/35 aneurysms 3D-CEMRA detected thrombosis with a difference between length of inner lumen dilatation on DSA and whole aneurysm length. 2/5 accessory renal arteries found on DSA were not detected on 3D-CEMRA. Conclusions: 3D-CEMRA is a valuable adjunct to DSA for pre-interventional diagnostics of aortic and peripheral arterial aneurysms. It provides exact evaluation of aneurysm dimensions and information about partial thrombosis.
引用
收藏
页码:985 / 991
页数:7
相关论文
共 32 条
[1]   DYNAMIC CONTRAST-ENHANCED SUBTRACTION MR-ANGIOGRAPHY OF THE LOWER-EXTREMITIES - INITIAL EVALUATION WITH A MULTISECTION 2-DIMENSIONAL TIME-OF-FLIGHT SEQUENCE [J].
ADAMIS, MK ;
LI, W ;
WIELOPOLSKI, PA ;
KIM, D ;
SAX, EJ ;
KENT, KC ;
EDELMAN, RR .
RADIOLOGY, 1995, 196 (03) :689-695
[2]  
BIEDERER J, 2000, ROFO FORTSCHR RONTG, V172, P307
[3]   Endoluminal stent-grafts for infrarenal abdominal aortic aneurysms [J].
Blum, U ;
Voshage, G ;
Lammer, J ;
Beyersdorf, F ;
Tollner, D ;
Kretschmer, G ;
Spillner, G ;
Polterauer, P ;
Nagel, G ;
Holzenbein, T ;
Thurnher, S ;
Langer, M .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (01) :13-20
[4]   Follow-up of aortic dissection: Contribution of MR angiography for evaluation of the abdominal aorta and its branches [J].
Bogaert, J ;
Meyns, B ;
Rademakers, FE ;
Bosmans, H ;
Verschakelen, J ;
Flameng, W ;
Marchal, G ;
Baert, AL .
EUROPEAN RADIOLOGY, 1997, 7 (05) :695-702
[5]   Contrast-enhanced MR angiography [J].
Bosmans, H ;
Marchal, G .
RADIOLOGE, 1996, 36 (02) :115-123
[6]  
Busch HP, 1999, ROFO-FORTSCHR RONTG, V170, P275
[7]   FAST MR-ANGIOGRAPHY OF THE AORTOILIAC ARTERIES AND ARTERIES OF THE LOWER-EXTREMITY - VALUE OF BOLUS-ENHANCED, WHOLE-VOLUME SUBTRACTION TECHNIQUE [J].
DOUEK, PC ;
REVEL, D ;
CHAZEL, S ;
FALISE, B ;
VILLARD, J ;
AMIEL, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) :431-437
[8]   Gadolinium-enhanced three-dimensional MR angiography of the entire aorta and iliac arteries with dynamic manual table translation [J].
Earls, JP ;
DeSena, S ;
Bluemke, DA .
RADIOLOGY, 1998, 209 (03) :844-849
[9]   Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: Usefulness of a timing examination and MR power injector [J].
Earls, JP ;
Rofsky, NM ;
DeCorato, DR ;
Krinsky, GA ;
Weinreb, JC .
RADIOLOGY, 1996, 201 (03) :705-710
[10]   First clinical results of ultrafast, gadolinium-enhanced dual-phase 3D MR-angiography in the abdomen. [J].
Gaa, J ;
Laub, G ;
Edelman, RR ;
Georgi, M .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 169 (02) :135-139