Noninvasive monitoring using serum amyloid A and serum neopterin in cardiac transplantation

被引:35
作者
Müller, TF
Vogl, M
Neumann, MC
Lange, H
Grimm, M
Müller, MM
机构
[1] Univ Marburg, Dept Nephrol, Ctr Internal Med, D-35033 Marburg, Germany
[2] Univ Vienna, Ludwig Boltzmann Inst Cardiosurg Res, A-1100 Vienna, Austria
[3] Kaiser Franz Josef Spital, Inst Lab Diagnost, A-1100 Vienna, Austria
[4] Univ Vienna, Dept Cardiothorac Surg, A-1100 Vienna, Austria
关键词
noninvasive monitoring; serum amyloid A; serum neopterin; cardiac transplantation;
D O I
10.1016/S0009-8981(98)00100-4
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The monitoring of allograft function for cardiac transplant patients still relies on endomyocardial routine biopsies. We investigated the diagnostic value of noninvasive monitoring using the parameters serum amyloid A protein and serum neopterin. The circulating levels of the acute phase reactant, amyloid A protein, and the macrophage product, neopterin, were measured serially in 13 patients after cardiac transplantation. The mean period of observation was 240 days. Nine acute cardiac allograft rejections, five cases of viral infection and eight cases of bacterial infection occurred. The levels of serum amyloid A protein and serum neopterin remained low ((x) over tilde = 6.0 mg/dL and 12.6 nmol/L, respectively) during the periods of stable graft function. In contrast, both parameters were significantly elevated (p < 0.01) during the rejection episodes ((x) over tilde = 12.7 mg/dL and 38.0 nmol/L for serum amyloid A protein and serum neopterin, respectively). For a reliable differentiation between rejection and stable graft function, serum amyloid A protein had a diagnostic accuracy of 84% (with a cut-off level of 10 mg/dL) and serum neopterin had one of 75% (with a cut-off level of 23 nmol/L). However, significant increases in the circulating levels of serum amyloid A protein and serum neopterin were also observed during bacterial ((x) over tilde = 14.9 and 88 nmol/L, respectively) and viral ((x) over tilde = 6.2 mg/dL and 44 nmol/L, respectively) infections. The detection of immunological complications after cardiac transplantation using serial measurements of serum amyloid A protein and serum neopterin is possible. These parameters can be used to help in judging both the need and the optimal timing for the otherwise frequent endomyocardial biopsies. (C) 1998 Elsevier Science BN. All rights reserved.
引用
收藏
页码:63 / 74
页数:12
相关论文
共 31 条
[11]  
KIRETT JM, 1990, J HEART TRANSPLANT, V9, P323
[12]  
KOBASHIGAWA J, 1992, J HEART LUNG TRANSPL, V11, P192
[13]  
KOSKINEN PK, 1994, TRANSPLANT INT S1, V7, P363
[14]   THE PROGNOSTIC VALUE OF C-REACTIVE PROTEIN AND SERUM AMYLOID-A PROTEIN IN SEVERE UNSTABLE ANGINA [J].
LIUZZO, G ;
BIASUCCI, LM ;
GALLIMORE, JR ;
GRILLO, RL ;
REBUZZI, AG ;
PEPYS, MB ;
MASERI, A .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (07) :417-424
[15]   Human serum amyloid A (SAA) protein: A prominent acute-phase reactant for clinical practice [J].
Malle, E ;
deBeer, FC .
EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 1996, 26 (06) :427-435
[16]   NEOPTERIN AS A NEW BIOCHEMICAL MARKER FOR DIAGNOSIS OF ALLOGRAFT-REJECTION - EXPERIENCE BASED UPON EVALUATION OF 100 CONSECUTIVE CASES [J].
MARGREITER, R ;
FUCHS, D ;
HAUSEN, A ;
HUBER, C ;
REIBNEGGER, G ;
SPIELBERGER, M ;
WACHTER, H .
TRANSPLANTATION, 1983, 36 (06) :650-653
[17]  
MAURY CPJ, 1984, CLIN NEPHROL, V22, P284
[18]  
Metsarinne K, 1993, Eur J Med, V2, P333
[19]   LONG-TERM COMPLICATIONS OF CARDIAC TRANSPLANTATION [J].
MILLER, LW .
PROGRESS IN CARDIOVASCULAR DISEASES, 1991, 33 (04) :229-282
[20]  
MULLER MM, 1994, DIAGNARE LABOR, V44, P14