Manganese(III) Porphyrin-based Potentiometric Sensors for Diclofenac Assay in Pharmaceutical Preparations

被引:35
|
作者
Vlascici, Dana [1 ]
Pruneanu, Stela [2 ]
Olenic, Liliana [2 ]
Pogacean, Florina [2 ]
Ostafe, Vasile [1 ]
Chiriac, Vlad [1 ]
Pica, Elena Maria [3 ]
Bolundut, Liviu Calm [3 ]
Nica, Luminita [4 ]
Fagadar-Cosma, Eugenia [5 ]
机构
[1] W Univ Timisoara, Timisoara 300223, Timis, Romania
[2] Natl Inst Res & Dev Isotop & Mol Technol, Cluj Napoca 400293, Romania
[3] Tech Univ Cluj Napoca, Fac Sci & Mat Engn, Cluj Napoca 400114, Romania
[4] Victor Babes Univ Med & Pharm Timisoara, Timisoara, Romania
[5] Timisora Romanian Acad, Inst Chem, Timisoara 300223, Romania
来源
SENSORS | 2010年 / 10卷 / 10期
关键词
diclofenac; manganese porphyrins; ion-selective electrodes; potentiometry; electrochemical impedance spectroscopy; pharmaceuticals; ION-SELECTIVE ELECTRODES; RESPONSE PROPERTIES; PVC; MEMBRANES; IONOPHORES; MN(III)TPP-CL; SUBSTITUENTS; FORMULATIONS; ASSOCIATE; EXCHANGE;
D O I
10.3390/s101008850
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two manganese(III) porphyrins: manganese(III) tetraphenylporphyrin chloride and manganese(III)-tetrakis(3-hydroxyphenyl)porphyrin chloride were tested as ionophores for the construction of new diclofenac selective electrodes. The electroactive material was incorporated either in PVC or a sol gel matrix. The effect of different plasticizers and additives (anionic and cationic) on the potentiometric response was studied. The best results were obtained for the PVC membrane plasticized with dioctylphtalate and having sodium tetraphenylborate as a lipophilic anionic additive incorporated. The sensor response was linear in the concentration range 3 x 10(-6) - 1 x 10(-2) M with a slope of -59.7 mV/dec diclofenac, a detection limit of 1.5 x 10(-6) M and very good selectivity coefficients. It was used for the determination of diclofenac in pharmaceutical preparations, by direct potentiometry. The results were compared with those obtained by the HPLC reference method and a good agreement was found between the two methods.
引用
收藏
页码:8850 / 8864
页数:15
相关论文
共 40 条
  • [31] Construction and evaluation of PVC and sol-gel sensor membranes based on Mn(III)TPP-Cl.: Application to valproate determination in pharmaceutical preparations
    Santos, EM
    Araújo, AN
    Couto, CMCM
    Montenegro, MCBSM
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 384 (04) : 867 - 875
  • [32] Potentiometric Response of Solid-State Sensors Based on Ferric Phosphate for Iron(III) Determination
    Paut, Andrea
    Prkic, Ante
    Mitar, Ivana
    Boskovic, Perica
    Jozic, Drazan
    Jakic, Mice
    Vukusic, Tina
    SENSORS, 2021, 21 (05) : 1 - 15
  • [33] Chloride Ion Sensor Based on Sol-Gel-Derived Membranes Modified Chemically with Porphyrin-Manganese(III) Complexes
    Yajima, Setsuko
    Ishigaki, Hiromasa
    Hori, Yusuke
    Takeaki, Rei
    Kimura, Keiichi
    BUNSEKI KAGAKU, 2012, 61 (03) : 207 - 212
  • [34] PVC-MEMBRANE POTENTIOMETRIC SENSORS BASED ON A RECENTLY SYNTHESIZED SCHIFF BASE FOR Fe(III) ION
    Sheikhshoaie, Iran
    Shamspur, Tayebeh
    Mostafavi, Ali
    Ebrahimipur, S. Yousef
    BULLETIN OF THE CHEMICAL SOCIETY OF ETHIOPIA, 2012, 26 (01) : 65 - 72
  • [35] Application of Precipitation-based and Nanoparticle-based Techniques for Fabrication of Potentiometric Sensors for Nano Molar Determination of Chitosan and Polyvinyl Pyrrolidone in Pharmaceutical Formulations and Biological Fluids
    Trabik, Yossra A.
    Al-Afify, Nourhan KH.
    El-Kosasy, Amira M.
    Magdy, N.
    ELECTROANALYSIS, 2021, 33 (05) : 1233 - 1243
  • [36] Carbon Nano-Dots based potentiometric sensor for the assay of the antiviral agent; Valacyclovir: In-Depth DFT Calculations, application to the pharmaceutical formulation and greenness assessment
    Hakiem, Ahmed Faried Abdel
    Kamal, Ahmed Mohsen
    Aboraia, Ahmed Safwat
    Mahfouz, M.
    Mohammed, Ahmed A. K.
    Naguib, Ibrahim A.
    Draz, Mohammed E.
    MICROCHEMICAL JOURNAL, 2024, 206
  • [37] Potentiometric Sensors for Pr(III) Based on N-N′o-Phenylene-bis(salicylideneimine) Using Epoxy Resin and PVC as Binding Materials
    Harish, K. Sharma
    Neha, Verma
    Kapoor, J. K.
    E-JOURNAL OF CHEMISTRY, 2011, 8 : S155 - S164
  • [38] Novel polymeric membrane sensors based on Mn(III) porphyrin and Co(II) phthalocyanine ionophores for batch and flow injection determination of azide
    Hassan, Saad S. M.
    Kelany, Ali E.
    Al-Mehrezi, Saeed S.
    ELECTROANALYSIS, 2008, 20 (04) : 438 - 443
  • [39] Iron(III)-selective membrane potentiometric sensor based on 5,10,15,20-tetrakis(pentafluorophenyl)-21H, 23H-porphyrin
    Fakhari, AR
    Alaghemand, M
    Shamsipur, M
    ANALYTICAL LETTERS, 2001, 34 (07) : 1097 - 1106
  • [40] PVC membrane and coated graphite potentiometric sensors based on 1-phenyl-3-pyridin-2-yl-thiourea for selective determination of iron(III)
    Motlagh, Masoud Ghanei
    Taher, Mohammad Ali
    Ahmadi, Ali
    ELECTROCHIMICA ACTA, 2010, 55 (22) : 6724 - 6730