Manganese(III) Porphyrin-based Potentiometric Sensors for Diclofenac Assay in Pharmaceutical Preparations

被引:35
|
作者
Vlascici, Dana [1 ]
Pruneanu, Stela [2 ]
Olenic, Liliana [2 ]
Pogacean, Florina [2 ]
Ostafe, Vasile [1 ]
Chiriac, Vlad [1 ]
Pica, Elena Maria [3 ]
Bolundut, Liviu Calm [3 ]
Nica, Luminita [4 ]
Fagadar-Cosma, Eugenia [5 ]
机构
[1] W Univ Timisoara, Timisoara 300223, Timis, Romania
[2] Natl Inst Res & Dev Isotop & Mol Technol, Cluj Napoca 400293, Romania
[3] Tech Univ Cluj Napoca, Fac Sci & Mat Engn, Cluj Napoca 400114, Romania
[4] Victor Babes Univ Med & Pharm Timisoara, Timisoara, Romania
[5] Timisora Romanian Acad, Inst Chem, Timisoara 300223, Romania
来源
SENSORS | 2010年 / 10卷 / 10期
关键词
diclofenac; manganese porphyrins; ion-selective electrodes; potentiometry; electrochemical impedance spectroscopy; pharmaceuticals; ION-SELECTIVE ELECTRODES; RESPONSE PROPERTIES; PVC; MEMBRANES; IONOPHORES; MN(III)TPP-CL; SUBSTITUENTS; FORMULATIONS; ASSOCIATE; EXCHANGE;
D O I
10.3390/s101008850
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two manganese(III) porphyrins: manganese(III) tetraphenylporphyrin chloride and manganese(III)-tetrakis(3-hydroxyphenyl)porphyrin chloride were tested as ionophores for the construction of new diclofenac selective electrodes. The electroactive material was incorporated either in PVC or a sol gel matrix. The effect of different plasticizers and additives (anionic and cationic) on the potentiometric response was studied. The best results were obtained for the PVC membrane plasticized with dioctylphtalate and having sodium tetraphenylborate as a lipophilic anionic additive incorporated. The sensor response was linear in the concentration range 3 x 10(-6) - 1 x 10(-2) M with a slope of -59.7 mV/dec diclofenac, a detection limit of 1.5 x 10(-6) M and very good selectivity coefficients. It was used for the determination of diclofenac in pharmaceutical preparations, by direct potentiometry. The results were compared with those obtained by the HPLC reference method and a good agreement was found between the two methods.
引用
收藏
页码:8850 / 8864
页数:15
相关论文
共 40 条
  • [21] Potentiometric determination of diclofenac in pharmaceutical formulation by membrane electrode based on ion associate with base dye
    Kormosh, Zholt
    Hunka, Iryna
    Bazel, Yaroslav
    CHINESE CHEMICAL LETTERS, 2007, 18 (09) : 1103 - 1106
  • [22] Ionophore-Based Polymeric Sensors for Potentiometric Assay of the Anticancer Drug Gemcitabine in Pharmaceutical Formulation: A Comparative Study
    Mostafa, Gamal A. E.
    El-Tohamy, Maha F.
    Ali, Essam A.
    Al-Salahi, Rashad
    Attwa, Mohamed W.
    Alrabiah, Haitham
    MOLECULES, 2023, 28 (22):
  • [23] Potentiometric Sensing of Aspirin Metabolite in Human Plasma and Pharmaceutical Preparations Using Co(III)-complex Based Electrodes: Experimental and Quantum Chemical Calculations
    Shehab, Ola R.
    Mansour, Ahmed M.
    ELECTROANALYSIS, 2016, 28 (05) : 1100 - 1111
  • [24] All-solid-state paper based potentiometric potassium sensors containing cobalt(II) porphyrin/cobalt(III) corrole in the transducer layer
    Jaworska, Ewa
    Pomarico, Giuseppe
    Berna, Beatrice Berionni
    Maksymiuk, Krzysztof
    Paolesse, Roberto
    Michalska, Agata
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 277 : 306 - 311
  • [25] Selectivity Enhancement for Chloride Ion by In(III)-Porphyrin-Based Polymeric Membrane Electrode Operated in Pulsed Chronopotentiometric Mode
    Gemene, Kebede L.
    Meyerhoff, Mark E.
    ELECTROANALYSIS, 2012, 24 (03) : 643 - 648
  • [26] POTENTIOMETRIC, ENANTIOSELECTIVE SENSORS FOR ALKYL AND ARYL AMMONIUM-IONS OF PHARMACEUTICAL SIGNIFICANCE, BASED ON LIPOPHILIC CYCLODEXTRINS
    KATAKY, R
    PARKER, D
    KELLY, PM
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1995, 55 (05) : 409 - 419
  • [27] Potentiometric determination of ascorbic acid in pharmaceutical preparations using a copper based mercury film electrode
    Riyazuddin, P
    Nazer, MMAK
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 16 (03) : 545 - 551
  • [28] Miniaturized ionophore-based potentiometric sensors for the flow-injection determination of metformin in pharmaceutical formulations and biological fluids
    Khaled, Elmorsy
    Kamel, Manal S.
    Hassan, Hassan N.
    Abd El-Alim, Sameh H.
    Aboul-Enein, Hassan Y.
    ANALYST, 2012, 137 (23) : 5680 - 5687
  • [29] Ionophore-Based Potentiometric Sensors for the Flow-Injection Determination of Promethazine Hydrochloride in Pharmaceutical Formulations and Human Urine
    Hassan, Ahmed Khudhair
    Saad, Bahruddin
    Ab Ghani, Sulaiman
    Adnan, Rohana
    Rahim, Afidah Abdul
    Ahmad, Norariza
    Mokhtar, Marina
    Ameen, Suham Towfiq
    Al-Araji, Suad Mustafa
    SENSORS, 2011, 11 (01) : 1028 - 1042
  • [30] Construction and evaluation of PVC and sol–gel sensor membranes based on Mn(III)TPP-Cl. Application to valproate determination in pharmaceutical preparations
    Emília M. G. Santos
    Alberto N. Araújo
    Cristina M. C. M. Couto
    M. Conceição B. S. M. Montenegro
    Analytical and Bioanalytical Chemistry, 2006, 384 : 867 - 875