Manganese(III) Porphyrin-based Potentiometric Sensors for Diclofenac Assay in Pharmaceutical Preparations

被引:35
|
作者
Vlascici, Dana [1 ]
Pruneanu, Stela [2 ]
Olenic, Liliana [2 ]
Pogacean, Florina [2 ]
Ostafe, Vasile [1 ]
Chiriac, Vlad [1 ]
Pica, Elena Maria [3 ]
Bolundut, Liviu Calm [3 ]
Nica, Luminita [4 ]
Fagadar-Cosma, Eugenia [5 ]
机构
[1] W Univ Timisoara, Timisoara 300223, Timis, Romania
[2] Natl Inst Res & Dev Isotop & Mol Technol, Cluj Napoca 400293, Romania
[3] Tech Univ Cluj Napoca, Fac Sci & Mat Engn, Cluj Napoca 400114, Romania
[4] Victor Babes Univ Med & Pharm Timisoara, Timisoara, Romania
[5] Timisora Romanian Acad, Inst Chem, Timisoara 300223, Romania
来源
SENSORS | 2010年 / 10卷 / 10期
关键词
diclofenac; manganese porphyrins; ion-selective electrodes; potentiometry; electrochemical impedance spectroscopy; pharmaceuticals; ION-SELECTIVE ELECTRODES; RESPONSE PROPERTIES; PVC; MEMBRANES; IONOPHORES; MN(III)TPP-CL; SUBSTITUENTS; FORMULATIONS; ASSOCIATE; EXCHANGE;
D O I
10.3390/s101008850
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two manganese(III) porphyrins: manganese(III) tetraphenylporphyrin chloride and manganese(III)-tetrakis(3-hydroxyphenyl)porphyrin chloride were tested as ionophores for the construction of new diclofenac selective electrodes. The electroactive material was incorporated either in PVC or a sol gel matrix. The effect of different plasticizers and additives (anionic and cationic) on the potentiometric response was studied. The best results were obtained for the PVC membrane plasticized with dioctylphtalate and having sodium tetraphenylborate as a lipophilic anionic additive incorporated. The sensor response was linear in the concentration range 3 x 10(-6) - 1 x 10(-2) M with a slope of -59.7 mV/dec diclofenac, a detection limit of 1.5 x 10(-6) M and very good selectivity coefficients. It was used for the determination of diclofenac in pharmaceutical preparations, by direct potentiometry. The results were compared with those obtained by the HPLC reference method and a good agreement was found between the two methods.
引用
收藏
页码:8850 / 8864
页数:15
相关论文
共 40 条
  • [1] A manganese porphyrin-based sensor for flow-injection potentiometric determination of thiocyanate
    Beheshti, Saeed S.
    Sohbat, Fatemeh
    Amini, Mohammad K.
    JOURNAL OF PORPHYRINS AND PHTHALOCYANINES, 2010, 14 (02) : 158 - 165
  • [2] Potentiometric Sensors for the Determination of Trifluoperazine Hydrochloride in Pharmaceutical Preparations
    Hassan, Ahmed K.
    Ameen, Suhaam T.
    Saad, Bahruddin
    Al-Aragi, Suad M.
    ANALYTICAL SCIENCES, 2009, 25 (11) : 1295 - 1299
  • [3] Potentiometric Sensors for Iodide and Bromide Based on Pt(II)-Porphyrin
    Vlascici, Dana
    Plesu, Nicoleta
    Fagadar-Cosma, Gheorghe
    Lascu, Anca
    Petric, Mihaela
    Crisan, Manuela
    Belean, Anca
    Fagadar-Cosma, Eugenia
    SENSORS, 2018, 18 (07)
  • [4] Potentiometric behaviour of ion selective electrodes based on iron porphyrins:: The influence of porphyrin substituents on the response properties and analytical determination of diclofenac in pharmaceutical formulations
    Santos, Emilia M. G.
    Araujo, Alberto N.
    Couto, Cristina M. C. M.
    Montenegro, M. Conceicao B. S. M.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 42 (05) : 535 - 542
  • [5] Porphyrin-based chemical sensors and multisensor arrays operating in the liquid phase
    Lvova, Larisa
    Di Natale, Corrado
    Paolesse, Roberto
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 179 : 21 - 31
  • [6] Potentiometric membrane sensors for the selective determination of cinnarizine in pharmaceutical preparations
    Hassan, SSM
    AbdelAziz, RM
    Abbas, AB
    ANALYTICA CHIMICA ACTA, 1996, 321 (01) : 47 - 52
  • [7] Ionophore-based potentiometric PVC membrane sensors for determination of phenobarbitone in pharmaceutical formulations
    Alrabiah, Haitham
    Al-Majed, Abdulrahman
    Abounassif, Mohammed
    Mostafa, Gamal A. E.
    ACTA PHARMACEUTICA, 2016, 66 (04) : 503 - 514
  • [8] Determination of diclofenac in pharmaceutical preparations using a potentiometric sensor immobilized in a graphite matrix
    Santini, AO
    Pezza, HR
    Pezza, L
    TALANTA, 2006, 68 (03) : 636 - 642
  • [9] Determination of fluoxetine in pharmaceutical preparations and biological samples using potentiometric sensors based on polymeric membranes
    M. Arvand
    N. Ahmadi Rad
    Journal of Analytical Chemistry, 2013, 68 : 183 - 188
  • [10] Determination of fluoxetine in pharmaceutical preparations and biological samples using potentiometric sensors based on polymeric membranes
    Arvand, M.
    Rad, N. Ahmadi
    JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 68 (02) : 183 - 188