X-ray spectrometry applied for determination of linear attenuation coefficient of tissue-equivalent materials (Reprinted from Radiation Physics and Chemistry, vol 160, pg 89-95, 2019)

被引:3
作者
Frimaio, Audrew [1 ]
Nascimento, Bruna C. [2 ]
Barrio, Ramon M. M. [2 ]
Campos, Leticia L. [1 ]
Costa, Paulo R. [2 ]
机构
[1] IPEN, Ave Prof Lineu Prestes 2242, BR-05508000 Sao Paulo, SP, Brazil
[2] Univ Sao Paulo, Inst Fis, Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
Phantoms; Tissue-equivalent; Attenuation coefficient; EFFECTIVE ATOMIC NUMBERS; SUBSTITUTE MATERIALS; WATER EQUIVALENCE; SOLID PHANTOMS; FORMULATION; ENERGY; CONSTRUCTION; DOSIMETRY;
D O I
10.1016/j.radphyschem.2019.108553
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Resin-based materials equivalent to water were developed and four different samples were obtained. The linear attenuation coefficients of all samples was evaluated using X-ray spectrometry with primary and transmitted beams using voltages at the ranging from 60 to 120 kV. The experimental measured values were compared with theoretical reference values to water and with that obtained using the Least Square Method algorithm methodology (method applied to diagnostic radiology and radiotherapy). Our results show that differences between the measured values and the target mu(E) was lower than 7%+/- 0.3 in the energy range from 20 to 80 keV. These results enable to consider that the material developed and produced is a good option to be used as a water-equivalent material and the experimental method adequate to its quantitative evaluation.
引用
收藏
页数:7
相关论文
共 44 条
  • [21] Evaluation of tissue-equivalent materials to be used as human brain tissue substitute in dosimetry for diagnostic radiology
    Ferreira, C. C.
    Ximenes Filho, R. E. M.
    Vieira, J. W.
    Tomal, A.
    Poletti, M. E.
    Garcia, C. A. B.
    Maia, A. F.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2010, 268 (16) : 2515 - 2521
  • [22] X-ray spectrometry applied for determination of linear attenuation coefficient of tissue-equivalent materials
    Frimaio, Audrew
    Nascimento, Bruna C.
    Barrio, Ramon M. M.
    Campos, Leticia L.
    Costa, Paulo R.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2019, 160 : 89 - 95
  • [23] Characterization of Tissue-Equivalent Materials Through Measurements of the Linear Attenuation Coefficient and Scattering Profiles Obtained With Polyenergetic Beams
    Geraldelli, Wender
    Tomal, Alessandra
    Poletti, Martin E.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (02) : 566 - 571
  • [24] Investigation of radiological properties and water equivalency of PRESAGE® dosimeters
    Gorjiara, Tina
    Hill, Robin
    Kuncic, Zdenka
    Adamovics, John
    Bosi, Stephen
    Kim, Jung-Ha
    Baldock, Clive
    [J]. MEDICAL PHYSICS, 2011, 38 (04) : 2265 - 2274
  • [25] POLYETHYLENE-BASED WATER-EQUIVALENT PHANTOM MATERIAL FOR X-RAY DOSIMETRY AT TUBE VOLTAGES FROM 10 TO 100 KV
    HERMANN, KP
    GEWORSKI, L
    MUTH, M
    HARDER, D
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (11) : 1195 - 1200
  • [26] A dosimetric evaluation of water equivalent phantoms for kilovoltage x-ray beams
    Hill, R
    Holloway, L
    Baldock, C
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (21) : N331 - N344
  • [27] Evaluation of the water equivalence of solid phantoms using gamma ray transmission measurements
    Hill, R. F.
    Brown, S.
    Baldock, C.
    [J]. RADIATION MEASUREMENTS, 2008, 43 (07) : 1258 - 1264
  • [28] The water equivalence of solid phantoms for low energy photon beams
    Hill, Robin
    Kuncic, Zdenka
    Baldock, Clive
    [J]. MEDICAL PHYSICS, 2010, 37 (08) : 4355 - 4363
  • [29] Review and history of photon cross section calculations
    Hubbell, J. H.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (13) : R245 - R262
  • [30] IAEA, 2007, Dosimetry in Diagnostic Radiology: an INTERNATIONAL CODE of PRACTICE, V457