The uses of 1-(2-pyridylazo) 2-naphtol (PAN) impregnated Ambersorb 563 resin on the solid-phase extraction of traces heavy metal ions and their determinations by atomic absorption spectrometry

被引:120
作者
Narin, I
Soylak, M [1 ]
机构
[1] Erciyes Univ, Fac Art & Sci, Dept Chem, TR-38039 Kayseri, Turkey
[2] Nigde Univ, Fac Art & Sci, Dept Chem, TR-51100 Nigde, Turkey
关键词
Ambersorb; 563; impregnation; PAN; preconcentration;
D O I
10.1016/S0039-9140(03)00039-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
1-(2-pyridylazo) 2-naphtol (PAN) impregnated Ambersorb 563 resin was used as solid phase extractor of copper, nickel, cadmium, lead, chromium and cobalt ions in aqueous solutions prior to their atomic absorption spectrometric determinations. The parameters including pH, sample volume, matrix effects were also investigated. The relative standard deviation (R.S.D.) of the combined method of sample treatment, preconcentration and determination with atomic absorption spectrometry is generally lower than 10%. The limit of detection was between 0.21 and 1.4 mug l(-1). The results were used for preconcentration of analyte ions from natural water samples. The method was also applied to a stream sediment standard reference material (GBW7309) for the determination of Cu, Ni, Cd, Pb, Cr and Co. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:215 / 221
页数:7
相关论文
共 31 条
[1]   A rapid spectrophotometric method for the determination of molybdenum in industrial, environmental, biological and soil samples using 5,7-dibromo-8-hydroxyquinoline [J].
Ahmed, MJ ;
Haque, ME .
ANALYTICAL SCIENCES, 2002, 18 (04) :433-439
[2]   Separation of gallium and indium from ores matrix by sorption on Amberlite XAD-2 coated with PAM [J].
Bermejo-Barrera, P ;
Martínez-Alsonso, N ;
Bermejo-Barrera, A .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 369 (02) :191-194
[3]  
Bhalotra A, 2002, QUIM ANAL, V20, P229
[4]  
Burguera JL, 2002, QUIM ANAL, V20, P255
[5]   Capability of diatomaceous earth to preconcentrate and store Pb and Cr:: on-line determination by FI-FAAS [J].
Cabañero, AI ;
Madrid, Y ;
Cámara, C .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (4-5) :244-250
[6]  
Capitán-Vallvey LF, 2002, QUIM ANAL, V20, P197
[7]  
Cesur H, 2002, TURK J CHEM, V26, P599
[8]   Determination of heavy metals in bio-collectors as indicator of environmental pollution [J].
Çinar, T ;
Elik, A .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2002, 82 (05) :321-329
[9]  
DOYBAK A, 1999, INT J MED BIOL ENV, V57, P51
[10]   Copper determination in natural water samples by using FAAS after preconcentration onto amberlite XAD-2 loaded with calmagite [J].
Ferreira, SLC ;
Ferreira, JR ;
Dantas, AF ;
Lemos, VA ;
Araújo, NML ;
Costa, ACS .
TALANTA, 2000, 50 (06) :1253-1259