Thermal performance analysis of a roof with a PCM-layer under Mexican weather conditions

被引:51
作者
Xaman, J. [1 ]
Rodriguez-Ake, A. [1 ,2 ]
Zavala-Guillen, I [2 ]
Hernandez-Perez, I [3 ]
Arce, J. [1 ]
Sauceda, D. [2 ]
机构
[1] Ctr Nacl Invest & Desarrollo Tecnol CENIDET TecNM, Prol Av Palmira S-N, Cuernavaca 62490, Morelos, Mexico
[2] Ctr Educ Cient & Educ Super Ensenada CICESE, Carretera Ensenada Tijuana 3918, Ensenada 22860, Baja California, Mexico
[3] Univ Juarez Autonoma Tabasco, Div Acad Ingn & Arquitectura DAIA UJAT, Carretera Cunduacan Jalpa de Mendez Km 1, Cunduacan 86690, Tabasco, Mexico
关键词
Phase change material; Roof; Mexican weather; PHASE-CHANGE MATERIALS; BUILDING ROOF; NUMERICAL-ANALYSIS; ECONOMIC-ANALYSIS; ENERGY; DESIGN; REDUCE; IMPACT; MODEL; HOLES;
D O I
10.1016/j.renene.2019.12.084
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The thermal performance of a concrete roof with a phase change material (PCM) layer on its interior surface under a Mexican warm weather (Merida) is presented. We analyzed a roof with three types of PCM: Paraffin wax - MG29 (R-PCM1), N-Eicosane (R-PCM2), and Salt Hydrates (R-PCM3). We also considered different thickness of the PCM layer. A conventional concrete roof (R-C) was considered as a reference to compare the results. The numerical simulations were conducted during the warmest and the coldest days of the year. A numerical in-house code was developed, and it was verified by solving reference solutions, obtaining good agreement. The results indicate that the case R-PCM1 with 2 cm of PCM layer had the lowest values of thermal load during the coldest (204.5 W h m(-2)) and the warmest day (610.7 W h m(-2)); such values are up to 57% lower than the thermal load corresponding to the R-C. The use of R-PCM1 with 2 cm of PCM-layer in Merida city will have a payback period of 12.18 years, Taking into account that buildings in Mexico have a 30-year ordinary service life, the use of these materials is cost-effective. Therefore, it is recommended the R-PCM1 to improve the thermal behavior of buildings located in Merida. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:773 / 785
页数:13
相关论文
共 47 条
[1]   Systematic evaluation of mathematical methods and numerical schemes for modeling PCM-enhanced building enclosure [J].
Al-Saadi, Saleh Nasser ;
Zhai, Zhiqiang .
ENERGY AND BUILDINGS, 2015, 92 :374-388
[2]   Building roof with conical holes containing PCM to reduce the cooling load: Numerical study [J].
Alawadhi, Esam M. ;
Alqallaf, Hashem J. .
ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (8-9) :2958-2964
[3]   Concrete roof with cylindrical holes containing PCM to reduce the heat gain [J].
Alqallaf, Hashem J. ;
Alawadhi, Esam M. .
ENERGY AND BUILDINGS, 2013, 61 :73-80
[4]  
American Society of Heating Refrigerating and Air-Conditioning Engineers, 2009, ASHRAE HDB FUND
[5]  
[Anonymous], 1980, Numerical Fluid Flow and Heat Transfer
[6]  
[Anonymous], 1980, SOLAR ENG THERMAL PR
[7]   Phase change material based cooling of photovoltaic panel: A simplified numerical model for the optimization of the phase change material layer and general economic evaluation [J].
Arici, Muslum ;
Bilgin, Feyza ;
Nizetic, Sandro ;
Papadopoulos, Agis M. .
JOURNAL OF CLEANER PRODUCTION, 2018, 189 :738-745
[8]   Thermal modeling of mineral insulator in paints for energy saving [J].
Azemati, Ali Akbar ;
Hadavand, Behzad Shirkavand ;
Hosseini, Hossein ;
Tajarrod, Abbas Salemi .
ENERGY AND BUILDINGS, 2013, 56 :109-114
[9]   NUMERICAL SOLUTION OF PHASE-CHANGE PROBLEMS [J].
BONACINA, C ;
COMINI, G ;
FASANO, A ;
PRIMICERIO, M .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1973, 16 (10) :1825-1832
[10]   Cool roofs impact on building thermal response: A French case study [J].
Bozonnet, E. ;
Doya, M. ;
Allard, F. .
ENERGY AND BUILDINGS, 2011, 43 (11) :3006-3012