Telehealth and Screening Strategies in the Diagnosis and Management of Glaucoma

被引:13
作者
Wong, Sze H. [1 ]
Tsai, James C. [1 ]
机构
[1] New York Eye & Ear Infirm Mt Sinai, Icahn Sch Med Mt Sinai, Dept Ophthalmol, New York, NY 10003 USA
关键词
telehealth; glaucoma; screening; monitoring; INTRAOCULAR-PRESSURE MEASUREMENTS; GOLDMANN APPLANATION TONOMETRY; OCULAR RESPONSE ANALYZER; NERVE-FIBER LAYER; CENTRAL CORNEAL THICKNESS; DEEP LEARNING-MODEL; TONO-PEN; NONCONTACT TONOMETRY; VISUAL-FIELD; CLINICAL-EVALUATION;
D O I
10.3390/jcm10163452
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Telehealth has become a viable option for glaucoma screening and glaucoma monitoring due to advances in technology. The ability to measure intraocular pressure without an anesthetic and to take optic nerve photographs without pharmacologic pupillary dilation using portable equipment have allowed glaucoma screening programs to generate enough data for assessment. At home, patients can perform visual acuity testing, web-based visual field testing, rebound tonometry, and video visits with the physician to monitor for glaucomatous progression. Artificial intelligence will enhance the accuracy of data interpretation and inspire confidence in popularizing telehealth for glaucoma.
引用
收藏
页数:20
相关论文
共 99 条
[1]   Evaluation of a Deep Learning System For Identifying Glaucomatous Optic Neuropathy Based on Color Fundus Photographs [J].
Al-Aswad, Lama A. ;
Kapoor, Rahul ;
Chu, Chia Kai ;
Walters, Stephen ;
Gong, Dan ;
Garg, Aakriti ;
Gopal, Kalashree ;
Patel, Vipul ;
Sameer, Trikha ;
Rogers, Thomas W. ;
Nicolas, Jaccard ;
De Moraes, Gustavo C. ;
Moazami, Golnaz .
JOURNAL OF GLAUCOMA, 2019, 28 (12) :1029-1034
[2]   Validation of a Deep Learning Model to Screen for Glaucoma Using Images from Different Fundus Cameras and Data Augmentation [J].
Asaoka, Ryo ;
Tanito, Masaki ;
Shibata, Naoto ;
Mitsuhashi, Keita ;
Nakahara, Kenichi ;
Fujino, Yuri ;
Matsuura, Masato ;
Murata, Hiroshi ;
Tokumo, Kana ;
Kiuchi, Yoshiaki .
OPHTHALMOLOGY GLAUCOMA, 2019, 2 (04) :224-231
[3]   Detecting Preperimetric Glaucoma with Standard Automated Perimetry Using a Deep Learning Classifier [J].
Asaoka, Ryo ;
Murata, Hiroshi ;
Iwase, Aiko ;
Araie, Makoto .
OPHTHALMOLOGY, 2016, 123 (09) :1974-1980
[4]   Agreement of Intraocular Pressure Measurement of Icare ic200 with Goldmann Applanation Tonometer in Adult Eyes with Normal Cornea [J].
Badakere, Swathi Vallabh ;
Chary, Raghava ;
Choudhari, Nikhil S. ;
Rao, Harsha L. ;
Garudadri, Chandrasekhar ;
Senthil, Sirisha .
OPHTHALMOLOGY GLAUCOMA, 2021, 4 (01) :89-94
[5]   Comparative Evaluation of Diaton and Goldmann Applanation Tonometers [J].
Bali, Shveta Jindal ;
Bhartiya, Shibal ;
Sobti, Amit ;
Dada, Tanuj ;
Panda, Anita .
OPHTHALMOLOGICA, 2012, 228 (01) :42-46
[6]   Comparison of intraocular pressure as measured by three different non-contact tonometers and goldmann applanation tonometer for non-glaucomatous subjects [J].
Bang, Seung Pil ;
Lee, Chong Eun ;
Kim, Yu Cheol .
BMC OPHTHALMOLOGY, 2017, 17
[7]   Tono-Pen versus Goldmann Applanation Tonometry [J].
Bao, Bo ;
Diaconita, Vlad ;
Schulz, David C. ;
Hutnik, Cindy .
OPHTHALMOLOGY GLAUCOMA, 2019, 2 (06) :435-439
[8]   Comparative evaluation of TonoPen AVIA, Goldmann applanation tonometry and non-contact tonometry [J].
Bhartiya S. ;
Bali S.J. ;
Sharma R. ;
Chaturvedi N. ;
Dada T. .
International Ophthalmology, 2011, 31 (4) :297-302
[9]   Comparison of three methods of intraocular pressure measurement and their relation to central corneal thickness [J].
Carbonaro, F. ;
Andrew, T. ;
Mackey, D. A. ;
Spector, T. D. ;
Hammond, C. J. .
EYE, 2010, 24 (07) :1165-1170
[10]   Digital camera system to perform infrared photography of iris transillumination [J].
Chan, EC ;
Roberts, DK ;
Loconte, DD ;
Wernick, MN .
JOURNAL OF GLAUCOMA, 2002, 11 (05) :426-428