Effect of External Magnetic Fields on the Breakdown and Partial Discharge Characteristics of Vegetable Oil

被引:0
作者
Li, Xiao Long [1 ]
Du, Bo Xue [1 ]
Xing, Yun Qi [1 ]
Li, Jin [1 ]
Jiang, Jin Peng [1 ]
机构
[1] Tianjin Univ, Sch Elect Engn & Automat, Key Lab Smart Grid, Educ Minist, Tianjin 300072, Peoples R China
来源
2015 IEEE INTERNATIONAL CONFERENCE ON APPLIED SUPERCONDUCTIVITY AND ELECTROMAGNETIC DEVICES (ASEMD) | 2015年
关键词
vegetable oil; partial discharge; breakdown strength; magnetic field; transformer; electric field;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Vegetable oil is based on natural ester oil, which is considered as the alternate natural source of traditional mineral insulating oil in electrical transformers. The oil applied in transformers performs dual functions of insulating and cooling materials. Partial discharges in an insulation system are incipient discharges that can damage materials and may eventually lead to complete failure of the electric transformer during operation. This paper presents an investigation on the effect of an external magnetic field on partial discharge (PD) characteristics of the vegetable oil applied in transformer. Although it has long been known that high magnetic fields are present in equipment, such as power transformers, where PD may occur, only a few investigations have been made on the effect of the magnetic field on the discharge characteristics of the traditional mineral oil. In the present study, magnetic fields of up to 500 mT were applied in the test oil samples with electric field stress simultaneously applied to produce PD. The PD characteristics along with the breakdown strength were recorded both before and after the application of the magnetic field.
引用
收藏
页码:520 / 521
页数:2
相关论文
共 8 条
[1]  
Amanullah M, 2005, I C DIELECT LIQUIDS, P365
[2]  
CIGRE, 2000, Technical Brochure 443
[3]   Electrical properties of vegetable oils between 20 Hz and 2 MHz [J].
Corach, J. ;
Sorichetti, P. A. ;
Romano, S. D. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2014, 39 (16) :8754-8758
[4]   Magnetic field disturbance of partial discharge activity in a cone-plane gap [J].
Hepburn, D. M. ;
Stewart, B. G. ;
Dissado, L. A. ;
Fothergill, J. C. .
2007 ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING EXPO, 2007, :142-+
[5]   Influence of Leakage Magnetic Fields on Partial Discharge Activity in Power Transformers [J].
Martinez-Tarifa, J. M. ;
Rivas-Conde, J. ;
Robles, G. ;
Sanz-Feito, J. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2010, 17 (06) :1724-1730
[6]   SO2 and CO gas removal and discharge characteristics of a nonthermal plasma reactor in a crossed dc magnetic field [J].
Moon, JD ;
Lee, GT ;
Chung, SH .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1999, 35 (05) :1198-1204
[7]   Vegetable oils for liquid-filled transformers [J].
Oommen, TV .
IEEE ELECTRICAL INSULATION MAGAZINE, 2002, 18 (01) :6-11
[8]   Sensitivity of transformer's hottest-spot and equivalent aging to selected parameters [J].
Peterchuck, D ;
Pahwa, A .
IEEE TRANSACTIONS ON POWER DELIVERY, 2002, 17 (04) :996-1001