The Metrological Traceability, Performance and Precision of European Radon Calibration Facilities

被引:7
作者
Beck, Thomas R. [1 ]
Antohe, Andrei [2 ]
Cardellini, Francesco [3 ]
Cucos, Alexandra [4 ]
Fialova, Eliska [5 ]
Grossi, Claudia [6 ]
Hening, Kinga [4 ]
Jensen, Jens [7 ]
Kastratovic, Dejan [8 ]
Krivosik, Matej [9 ]
Lobner, Patrick [10 ]
Luca, Aurelian [2 ]
Maringer, Franz Josef [10 ]
Michielsen, Nathalie [11 ]
Otahal, Petr P. S. [5 ]
Quindos, Luis [12 ]
Rabago, Daniel [12 ]
Sainz, Carlos [12 ]
Szucs, Laszlo [13 ]
Teodorescu, Constantin [2 ]
Tolinsson, Cathrin [7 ]
Tugulan, Cornel Liviu [2 ]
Turtiainen, Tuukka [14 ]
Vargas, Arturo [6 ]
Vosahlik, Josef [5 ]
Vukoslavovic, Goran [8 ]
Wiedner, Hannah [10 ]
Woloszczuk, Katarzyna [15 ]
机构
[1] Fed Off Radiat Protect, D-10318 Berlin, Germany
[2] Inst Natl Cercetare Dezvoltare Pentru Fiz & Ingn, Ilfov Cty 077125, Romania
[3] ENEA INMRI, I-00123 Rome, Italy
[4] Babes Bolyai Univ, Fac Environm Sci & Engn, CONSTANTIN COSMA Radon Lab, Cluj Napoca 400294, Romania
[5] Statni Ustav Jaderne Chem & Biol Ochrany, Milin 26231, Czech Republic
[6] Univ Politecn Cataluna, Inst Tecn Energet, Lab 222Rn Studies, Barcelona 08028, Spain
[7] Swedish Radiat Safety Author, S-17116 Stockholm, Sweden
[8] Bur Metrol, Podgorica 81000, Montenegro
[9] Slovak Inst Metrol, Dept Ionizing Radiat, Bratislava 84255, Slovakia
[10] Bundesamt Eich & Vermessungswesen, Phys Tech Prufdienst, A-1160 Vienna, Austria
[11] Inst Radioprotect & Surete Nucl, F-92262 Paris, France
[12] Univ Cantabria, Radon Grp, Lab Environm Radioact, Santander 39011, Spain
[13] Budapest Fovar Kormanyhivatala, H-1024 Budapest, Hungary
[14] Radiat & Nucl Safety Author, Helsinki 00880, Finland
[15] Cent Lab Radiol Protect, PL-03194 Warsaw, Poland
关键词
radon; interlaboratory comparison; radon activity concentration; calibration; metrological traceability;
D O I
10.3390/ijerph182212150
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An interlaboratory comparison for European radon calibration facilities was conducted to evaluate the establishment of a harmonized quality level for the activity concentration of radon in air and to demonstrate the performance of the facilities when calibrating measurement instruments for radon. Fifteen calibration facilities from 13 different European countries participated. They represented different levels in the metrological hierarchy: national metrology institutes and designated institutes, national authorities for radiation protection and participants from universities. The interlaboratory comparison was conducted by the German Federal Office for Radiation Protection (BfS) and took place from 2018 to 2020. Participants were requested to measure radon in atmospheres of their own facilities according to their own procedures and requirements for metrological traceability. A measurement device with suitable properties was used to determine the comparison values. The results of the comparison showed that the radon activity concentrations that were determined by European calibration facilities complying with metrological traceability requirements were consistent with each other and had common mean values. The deviations from these values were normally distributed. The range of variation of the common mean value was a measure of the degree of agreement between the participants. For exposures above 1000 Bq/m(3), the variation was about 4% for a level of confidence of approximately 95% (k=2). For lower exposure levels, the variation increased to about 6%.
引用
收藏
页数:15
相关论文
共 8 条
[1]  
BIPM-CCQM, 2013, GUID NOT EST CONS KC
[2]  
Cox MG, 2002, METROLOGIA, V39, P589, DOI 10.1088/0026-1394/39/6/10
[3]  
EMPIR Project Metrology for Radon, DEL D7 VAL REP TRAC
[4]  
ISO/IEC, 2008, ISO/IEC Guide 98-3: Uncertainty of Measurement
[5]   Determination of a reference value and its uncertainty through a power-moderated mean [J].
Pomme, S. ;
Keightley, J. .
METROLOGIA, 2015, 52 (03) :S200-S212
[6]  
Reimer M, 2014, SPATIAL PLANNING SYSTEMS AND PRACTICES IN EUROPE: A COMPARATIVE PERSPECTIVE ON CONTINUITY AND CHANGES, P1
[7]   Radon activity concentration -: a Euromet and BIPM supplementary comparison [J].
Roettger, A. ;
Honig, A. ;
Schmidt, V. ;
Buchroeder, H. ;
Rox, A. ;
Butterweck, G. ;
Schuler, Ch. ;
Maringer, F. J. ;
Jachs, P. ;
Edelmaier, R. ;
Michielsen, N. ;
Howarth, C. B. ;
Miles, J. C. H. ;
Vargas, A. ;
Ortega, X. ;
Burian, I. ;
Turtiainen, T. ;
Hagberg, N. .
APPLIED RADIATION AND ISOTOPES, 2006, 64 (10-11) :1102-1107
[8]   Weighted means statistics in interlaboratory studies [J].
Rukhin, Andrew L. .
METROLOGIA, 2009, 46 (03) :323-331