Rapid and Sensitive Detection of the Food Allergen Glycinin in Powdered Milk Using a Lateral Flow Colloidal Gold Immunoassay Strip Test

被引:65
|
作者
Wang, Yao [1 ]
Deng, Ruiguang [2 ]
Zhang, Gaiping [2 ,3 ]
Li, Qingmei [2 ]
Yang, Jifei [2 ]
Sun, Yaning [2 ]
Li, Zhixi [1 ]
Hu, Xiaofei [2 ]
机构
[1] Northwest A&F Univ, Coll Food Sci & Engn, Yangling 712100, Shaanxi, Peoples R China
[2] Henan Acad Agr Sci, Henan Key Lab Anim Immunol, Zhengzhou 450002, Henan, Peoples R China
[3] Henan Agr Univ, Coll Anim Sci & Vet Med, Zhengzhou 450002, Henan, Peoples R China
关键词
glycinin; immunochromatographic strip; colloidal gold; immunoassay; LINKED-IMMUNOSORBENT-ASSAY; BETA-CONGLYCININ; SOYBEAN PRODUCTS; SOY PROTEINS; 7S GLOBULIN; RESIDUES; ANTIBODY;
D O I
10.1021/jf5052128
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
A rapid immunochromatographic lateral flow test strip in a sandwich format was developed with the colloidal gold-labeled mouse antiglycinin monoclonal antibody (mAb) and rabbit antiglycinin polyclonal antibody (pAb) to specifically identify glycinin, a soybean allergen. The test strip is composed of a sample pad, a conjugate reagent pad, an absorbent pad, and a test membrane containing a control line and a test line. This test strip has high sensitivity, and results can be obtained within 10 min without sophisticated procedures. The limit of detection (LOD) of the test strip was calculated to be 0.69 mg/kg using an optical density scanner that measures relative optical density. The assay showed high specificity for glycinin, with no cross-reactions with other soybean proteins or other food allergens. The recoveries of the lateral flow test strip in detecting glycinin in powdered milk samples ranged between 80.5 and 89.9% with relative standard deviations of less than 5.29% (intra-assay) and 6.72% (interassay). Therefore, the test strip is useful as a quantitative, semiquantitative, or qualitative detection method for glycinin in powdered milk. In addition, the test strip can be used to detect glycinin in other processed foods and may be a valuable tool in identifying effective approaches for reducing the impact of glycinin.
引用
收藏
页码:2172 / 2178
页数:7
相关论文
共 50 条
  • [1] Establishment of a Lateral Flow Colloidal Gold Immunoassay Strip for the Rapid Detection of Soybean Allergen β-Conglycinin
    Wang, Yao
    Li, Zhaozhou
    Pei, Yafeng
    Li, Qingmei
    Sun, Yaning
    Yang, Jifei
    Yang, Yanyan
    Zhi, Yubao
    Deng, Ruiguang
    Hou, Yuze
    Hu, Xiaofei
    FOOD ANALYTICAL METHODS, 2017, 10 (07) : 2429 - 2435
  • [2] Establishment of a Lateral Flow Colloidal Gold Immunoassay Strip for the Rapid Detection of Soybean Allergen β-Conglycinin
    Yao Wang
    Zhaozhou Li
    Yafeng Pei
    Qingmei Li
    Yaning Sun
    Jifei Yang
    Yanyan Yang
    Yubao Zhi
    Ruiguang Deng
    Yuze Hou
    Xiaofei Hu
    Food Analytical Methods, 2017, 10 : 2429 - 2435
  • [3] Establishment of a lateral flow colloidal gold immunoassay strip for the rapid detection of estradiol in milk samples
    Yang, Xing-dong
    Wang, Fang-yu
    Song, Chun-mei
    Wu, Shu-yan
    Zhang, Gai-ping
    Zeng, Xian-yin
    LWT-FOOD SCIENCE AND TECHNOLOGY, 2015, 64 (01) : 88 - 94
  • [4] Rapid detection of cow milk adulteration/contamination in goat milk by a lateral flow colloidal gold immunoassay strip
    Liu, Bochao
    Si, Jinhong
    Zhao, Fang
    Wang, Qi
    Wang, Yu
    Li, Jinfeng
    Li, Chengyao
    Li, Tingting
    JOURNAL OF DAIRY RESEARCH, 2019, 86 (01) : 94 - 97
  • [5] Utilization of a lateral flow colloidal gold immunoassay strip based on surface-enhanced Raman spectroscopy for rapid detection of glycinin
    Huang, Pengbo
    Shang, Achen
    Liu, Deguo
    Xi, Jun
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2023, 293
  • [6] Development of a Lateral Flow Colloidal Gold Immunoassay Strip for the Rapid Detection of Olaquindox Residues
    Song, Chunmei
    Liu, Qingtang
    Zhi, Aimin
    Yang, Jifei
    Zhi, Yubao
    Li, Qingmei
    Hu, Xiaofei
    Deng, Ruiguang
    Casas, Justin
    Tang, Liang
    Zhang, Gaiping
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2011, 59 (17) : 9319 - 9326
  • [7] Development of a Lateral Flow Colloidal Gold Immunoassay Strip for the Rapid Detection of Enrofloxacin Residues
    Zhao, Yinli
    Zhang, Gaiping
    Liu, Qingtang
    Teng, Man
    Yang, Jifei
    Wang, Jianhua
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2008, 56 (24) : 12138 - 12142
  • [8] Lateral flow test strip based on colloidal selenium immunoassay for rapid detection of melamine in milk, milk powder, and animal feed
    Wang, Zhizeng
    Zhi, Dejuan
    Zhao, Yang
    Zhang, Hailong
    Wang, Xin
    Ru, Yi
    Li, Hongyu
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2014, 9 : 1699 - 1707
  • [9] Gold nanoparticle-based lateral flow immunoassay for the rapid and on-site detection of wheat allergen in milk
    Hu, Jialin
    Xu, Xinxin
    Xu, Liguang
    Kuang, Hua
    Xu, Chuanlai
    Guo, Lingling
    FOOD BIOSCIENCE, 2023, 51
  • [10] An Immunochromatographic Lateral Flow Strip Test for the Rapid Detection of Danofloxacin in Milk
    Yang, Xingdong
    Wang, Yinbiao
    Yang, Jifei
    Sun, Zhongke
    Yue, Zonghao
    Li, Lili
    He, Le
    Hu, Xiaofei
    FOOD ANALYTICAL METHODS, 2019, 12 (11) : 2430 - 2437