Development of an electrochemical sensor for nitric oxide based on carbon paste electrode modified with Nafion, gold nanoparticles and graphene nanoribbons

被引:26
|
作者
Wenninger, Nadine [1 ]
Bracic, Urska [1 ]
Kollau, Alexander [2 ]
Pungjunun, Kingkan [3 ]
Leitinger, Gerd [4 ]
Kalcher, Kurt [5 ]
Ortner, Astrid [1 ]
机构
[1] Karl Franzens Univ Graz, Inst Pharmaceut Sci, Dept Pharmaceut Chem, Schubertstr 1, A-8010 Graz, Austria
[2] Karl Franzens Univ Graz, Inst Pharmaceut Sci, Dept Pharmacol & Toxicol, Humboldtstr 46-1, A-8010 Graz, Austria
[3] Chulalongkorn Univ, Fac Sci, Electrochem & Opt Spect Ctr Excellence EOSCE, Dept Chem, 254 Phayathai Rd, Bangkok 10330, Thailand
[4] Med Univ Graz, Dept Cell Biol Histol & Embryol, Res Unit Electron Microscop Methods, Neue Stiftingtalstr 6, A-8010 Graz, Austria
[5] Karl Franzens Univ Graz, Inst Chem, Dept Analyt Chem, Univ Pl 1, A-8010 Graz, Austria
关键词
Nitric oxide; Electrocatalysis; Carbon paste electrode; Gold nanoparticles; Graphene nanoribbons; Electrochemical determination; RELEASE; NEURODEGENERATION; MICROSENSOR; FILM;
D O I
10.1016/j.snb.2021.130532
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Various physiological as well as pathophysiological processes in the cardiovascular system, in the immune response or in neurotransmission depend on changes of the concentration of nitric oxide (NO). Due to the instability of this ubiquitous signal molecule in vivo and in vitro, its rapid and direct detection is necessary to obtain meaningful results. Therefore, the development of a method for the rapid electrochemical detection of nitric oxide at 0.72 V (vs. Ag/AgCl) using a carbon paste electrode, modified by drop casting, is presented. As modifying solution, a nanocomposite consisting of Nafion, graphene nanoribbons, and gold nanoparticles was prepared. The voltammetric investigations with the optimized sensor were performed at room temperature in phosphate buffer solution (0.1 M, pH 7.4) as supporting electrolyte. Based on differential pulse voltammetry measurements, the obtained results for the analytical signal showed good linear response in the range of 0.39-2.34 mu M and 2.34-104.7 mu M with a correlation coefficient of 0.9941 and 0.9984, respectively. For both linear ranges, the repeatability as well as the reproducibility was <5% and <10%, respectively. A concentration of 40 nM was determined for the detection limit, whereas the limit of quantification was 130 nM. In addition, the influence of physiological interferences was also investigated and resulted in negligible effects. Finally, the sensor was successfully used to measure the NO release of NO donors. Based on the results obtained, the new sensor provides a simple and fast method for a direct voltammetric determination of low nitric oxide concentrations in solutions.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] An amperometric sensor for nitric oxide based on a glassy carbon electrode modified with graphene, Nafion, and electrodeposited gold nanoparticles
    Wang, Yazhen
    Song, Bin
    Xu, Junhui
    Hu, Shengshui
    MICROCHIMICA ACTA, 2015, 182 (3-4) : 711 - 718
  • [2] An amperometric sensor for nitric oxide based on a glassy carbon electrode modified with graphene, Nafion, and electrodeposited gold nanoparticles
    Yazhen Wang
    Bin Song
    Junhui Xu
    Shengshui Hu
    Microchimica Acta, 2015, 182 : 711 - 718
  • [3] A Sensitive Electrochemical Sensor for Moxifloxacin Hydrochloride Based on Nafion/Graphene Oxide/Zeolite Modified Carbon Paste Electrode
    Fekrya, Amany M.
    Abdel-Gawad, Soha A.
    Azab, Shereen M.
    Walcarius, Alain
    ELECTROANALYSIS, 2021, 33 (04) : 964 - 974
  • [4] Determination of morphine at gold nanoparticles/Nafion® carbon paste modified sensor electrode
    Atta, Nada F.
    Galal, Ahmed
    Azab, Shereen M.
    ANALYST, 2011, 136 (22) : 4682 - 4691
  • [5] Electrochemical Morphine Sensor Based on Gold Nanoparticles Metalphthalocyanine Modified Carbon Paste Electrode
    Atta, Nada F.
    Galal, Ahmed
    Abdel-Gawad, Fatma M.
    Mohamed, Eman F.
    ELECTROANALYSIS, 2015, 27 (02) : 415 - 428
  • [6] Electrochemical Determination of Neurotransmitters Using Gold Nanoparticles on Nafion/Carbon Paste Modified Electrode
    Atta, Nada F.
    Galal, Ahmed
    Azab, Shereen M.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2012, 159 (10) : H765 - H771
  • [7] Electrochemical sensor for the determination of ketoconazole based on gold nanoparticles modified carbon paste electrode
    Saleh, Tawfik A.
    AlAqad, Khaled M. M.
    Rahim, Abdur
    JOURNAL OF MOLECULAR LIQUIDS, 2018, 256 : 39 - 48
  • [8] Novel sensor based on carbon paste/Nafion® modified with gold nanoparticles for the determination of glutathione
    Nada F. Atta
    Ahmed Galal
    Shereen M. Azab
    Analytical and Bioanalytical Chemistry, 2012, 404 : 1661 - 1672
  • [9] Electrochemical Sensor Based on Nafion/Gold Nanoparticle/Electrochemically Reduced Graphene Oxide Composite-Modified Glassy Carbon Electrode for the Detection of Diuron
    Qin, Jianfang
    Qin, YingLian
    Jiang, Xiuping
    Du, Yajin
    Du, Yajing
    Yao, Chen-Zhong
    Wang, Xi
    Yang, Haiying
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (11): : 11203 - 11214
  • [10] Voltammetric sensor for caffeine based on a glassy carbon electrode modified with Nafion and graphene oxide
    Fangyuan Zhao
    Fei Wang
    Weining Zhao
    Jing Zhou
    Yang Liu
    Lina Zou
    Baoxian Ye
    Microchimica Acta, 2011, 174 : 383 - 390