Intentional Fracture of Bioprosthetic Valve Frames in Patients Undergoing Valve-in-Valve Transcatheter Pulmonary Valve Replacement

被引:44
作者
Shahanavaz, Shabana [1 ]
Asnes, Jeremy D. [2 ]
Grohmann, Jochen [3 ]
Qureshi, Athar M. [4 ]
Rome, Jonathan J. [5 ]
Tanase, Daniel [6 ]
Crystal, Matthew A. [7 ]
Latson, Larry A. [8 ]
Morray, Brian H. [9 ]
Hellenbrand, William [2 ]
Balzer, David T. [1 ]
Gewillig, Marc [10 ]
Love, Jon C. [11 ]
Berdjis, Farhouch [12 ]
Gillespie, Matthew J. [5 ]
McElhinney, Doff B. [13 ,14 ]
机构
[1] Washington Univ, Dept Pediat, Div Cardiol, Sch Med, St Louis, MO 63110 USA
[2] Yale Univ, New Haven, CT USA
[3] Univ Freiburg, Heart Ctr, Dept Congenital Heart Defects & Pediat Cardiol, Freiburg, Germany
[4] Baylor Coll Med, Texas Childrens Hosp, Lillie Frank Abercrombie Sect Cardiol, Houston, TX 77030 USA
[5] Childrens Hosp Philadelphia, Philadelphia, PA 19104 USA
[6] German Heart Ctr, Dept Paediat Cardiol & Congenital Heart Defects, Munich, Germany
[7] Columbia Univ, Med Ctr, Morgan Stanley Childrens Hosp, Div Pediat Cardiol, New York, NY USA
[8] Joe DiMaggio Childrens Hosp, Dept Cardiol, Hollywood, FL USA
[9] Univ Washington, Sch Med, Seattle Childrens Hosp, Div Pediat Cardiol, Seattle, WA 98195 USA
[10] Univ Hosp Leuven, Dept Pediat Cardiol, Leuven, Belgium
[11] Univ New Mexico, Div Pediat Cardiol, Albuquerque, NM 87131 USA
[12] Childrens Hosp Orange Cty, Orange, CA 92668 USA
[13] Stanford Univ, Sch Med, Dept Pediat, Lucile Packard Childrens Hosp Heart Ctr, Palo Alto, CA 94304 USA
[14] Stanford Univ, Sch Med, Dept Cardiothorac Surg, Lucile Packard Childrens Hosp Heart Ctr, Palo Alto, CA 94304 USA
关键词
hemodynamics; prostheses and implants; pulmonary valve; stents; tetralogy of Fallot; CONGENITAL HEART-DISEASE; PERIMOUNT BIOPROSTHESIS; MULTICENTER EXPERIENCE; RISK-FACTORS; IMPLANTATION; DEGENERATION; PLACEMENT; MISMATCH; POSITION; CRACKING;
D O I
10.1161/CIRCINTERVENTIONS.118.006453
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Percutaneous transcatheter pulmonary valve replacement (TPVR) has good clinical and hemodynamic outcomes in treating dysfunctional bioprosthetic valves (BPV) in the pulmonary position. Valve-in-valve therapy can further decrease the inner diameter (ID), potentially resulting in patient-prosthesis mismatch in patients with smaller BPVs. METHODS AND RESULTS: To evaluate feasibility and outcomes of intentional BPV fracture to enlarge the pulmonary valve orifice with TPVR, 37 patients from 13 centers who underwent TPVR with intended BPV fracture were evaluated. A control cohort (n=70) who underwent valve-in-valve TPVR without attempted fracture was evaluated. BPV was successfully fractured in 28 patients and stretched in 5 while fracture was unsuccessful in 4. A Melody valve was implanted in 25 patients with fractured/stretched frame and a Sapien (XT 3) valve in 8. Among patients whose BPV was fractured/stretched, the final ID was a median of 2 mm larger (0-6.5 mm) than the valve's true ID. The narrowest diameter after TPVR in controls was a median of 2 mm smaller (P<0.001) than true ID. Right ventricular outflow tract gradient decreased from median 40 to 8 mmHg in the fracture group. Cases with fracture/stretching were matched 1:1 (weight, true ID) to controls. Post-TPVR peak gradient was lower but not significant (8.35.2 versus 11.8 +/- 9.2 mmHg; P=0.070). There were no fracture-related adverse events. CONCLUSIONS: Preliminary experience shows intentional fracture of BPV frame can be useful for achieving larger ID and better hemodynamics after valve-in-valve TPVR.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Failed bioprosthetic valve approaches: Transcatheter aortic valve replacement approach
    Clark, Aaron
    Malaisrie, S. Chris
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2022, 163 (05) : 1795 - 1798
  • [42] Yearly Trends and In-Hospital Outcomes of Patients Undergoing Transcatheter Mitral Valve-In-Valve Replacement in Prosthetic Valve Dysfunction
    Jamshed, Aneeza
    Gajjar, Rohan
    Vardar, Ufuk
    Abbasi, Ayesha
    Karki, Sadichhya
    Kumi, Dennis
    Kumar, Manoj
    Aziz, Imran
    Bello, Jeremiah
    Dhar, Gaurav
    Jolly, Neeraj
    Vij, Aviral
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2025, 105 (01) : 239 - 248
  • [43] A comparison of valve-in-valve transcatheter aortic valve replacement in failed stentless versus stented surgical bioprosthetic aortic valves
    Choi, Charles H.
    Cheng, Vivian
    Malaver, Diego
    Kon, Neal
    Kincaid, Edward H.
    Gandhi, Sanjay K.
    Applegate, Robert J.
    Zhao, David X. M.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2019, 93 (06) : 1106 - 1115
  • [44] Transcatheter Valve-in-Valve Aortic Valve Replacement as an Alternative to Surgical Re-Replacement
    Deharo, Pierre
    Bisson, Arnaud
    Herbert, Julien
    Lacour, Thibaud
    Saint Etienne, Christophe
    Porto, Alizee
    Theron, Alexis
    Collart, Frederic
    Bourguignon, Thierry
    Cuisset, Thomas
    Fauchier, Laurent
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (05) : 489 - 499
  • [45] Outcomes of redo pulmonary valve replacement for bioprosthetic pulmonary valve failure in 61 patients with congenital heart disease
    Lee, Cheul
    Lee, Chang-Ha
    Kwak, Jae Gun
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2016, 50 (03) : 470 - 475
  • [46] A step-by-step guide to transseptal valve-in-valve transcatheter mitral valve replacement
    Harloff, Morgan T.
    Chowdhury, Muntasir
    Hirji, Sameer A.
    Percy, Edward D.
    Yazdchi, Farhang
    Shim, Hunbo
    Malarczyk, Alexandra A.
    Sobieszczyk, Piotr S.
    Sabe, Ashraf A.
    Shah, Pinak B.
    Kaneko, Tsuyoshi
    ANNALS OF CARDIOTHORACIC SURGERY, 2021, 10 (01) : 113 - 121
  • [47] Valve-in-valve transcatheter aortic valve replacement versus redo surgical valve replacement for degenerated bioprosthetic aortic valve: An updated meta-analysis comparing midterm outcomes
    Thandra, Abhishek
    Abusnina, Waiel
    Jhand, Aravdeep
    Shaikh, Kashif
    Bansal, Raahat
    Pajjuru, Venkata S.
    Al-Abdouh, Ahmad
    Kanmanthareddy, Arun
    Alla, Venkata M.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2021, 97 (07) : 1481 - 1488
  • [48] Editorial: Minding the Gradient - Valve-in-Valve Transcatheter Aortic Valve Replacement vs. Redo Surgical Aortic Valve Replacements for Surgical Bioprosthetic Valve Failure
    Zaid, Syed
    Kleiman, Neal S.
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2022, 6 (06):
  • [49] Transcatheter pulmonary valve replacement using the melody valve for treatment of dysfunctional surgical bioprostheses: A multicenter study
    Cabalka, Allison K.
    Asnes, Jeremy D.
    Balzer, David T.
    Cheatham, John P.
    Gillespie, Matthew J.
    Jones, Thomas K.
    Justino, Henri
    Kim, Dennis W.
    Lung, Te-Hsin
    Turner, Daniel R.
    McElhinney, Doff B.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 155 (04) : 1712 - +
  • [50] Contrast-free percutaneous pulmonary valve replacement: a safe approach for valve-in-valve procedures
    O'Callaghan, Barry
    Zablah, Jenny
    Leahy, Ryan
    Shorofsky, Michael
    Kay, Joseph
    Morgan, Gareth
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2021, 17 (02): : 200 - 209