Intentional Fracture of Bioprosthetic Valve Frames in Patients Undergoing Valve-in-Valve Transcatheter Pulmonary Valve Replacement

被引:44
作者
Shahanavaz, Shabana [1 ]
Asnes, Jeremy D. [2 ]
Grohmann, Jochen [3 ]
Qureshi, Athar M. [4 ]
Rome, Jonathan J. [5 ]
Tanase, Daniel [6 ]
Crystal, Matthew A. [7 ]
Latson, Larry A. [8 ]
Morray, Brian H. [9 ]
Hellenbrand, William [2 ]
Balzer, David T. [1 ]
Gewillig, Marc [10 ]
Love, Jon C. [11 ]
Berdjis, Farhouch [12 ]
Gillespie, Matthew J. [5 ]
McElhinney, Doff B. [13 ,14 ]
机构
[1] Washington Univ, Dept Pediat, Div Cardiol, Sch Med, St Louis, MO 63110 USA
[2] Yale Univ, New Haven, CT USA
[3] Univ Freiburg, Heart Ctr, Dept Congenital Heart Defects & Pediat Cardiol, Freiburg, Germany
[4] Baylor Coll Med, Texas Childrens Hosp, Lillie Frank Abercrombie Sect Cardiol, Houston, TX 77030 USA
[5] Childrens Hosp Philadelphia, Philadelphia, PA 19104 USA
[6] German Heart Ctr, Dept Paediat Cardiol & Congenital Heart Defects, Munich, Germany
[7] Columbia Univ, Med Ctr, Morgan Stanley Childrens Hosp, Div Pediat Cardiol, New York, NY USA
[8] Joe DiMaggio Childrens Hosp, Dept Cardiol, Hollywood, FL USA
[9] Univ Washington, Sch Med, Seattle Childrens Hosp, Div Pediat Cardiol, Seattle, WA 98195 USA
[10] Univ Hosp Leuven, Dept Pediat Cardiol, Leuven, Belgium
[11] Univ New Mexico, Div Pediat Cardiol, Albuquerque, NM 87131 USA
[12] Childrens Hosp Orange Cty, Orange, CA 92668 USA
[13] Stanford Univ, Sch Med, Dept Pediat, Lucile Packard Childrens Hosp Heart Ctr, Palo Alto, CA 94304 USA
[14] Stanford Univ, Sch Med, Dept Cardiothorac Surg, Lucile Packard Childrens Hosp Heart Ctr, Palo Alto, CA 94304 USA
关键词
hemodynamics; prostheses and implants; pulmonary valve; stents; tetralogy of Fallot; CONGENITAL HEART-DISEASE; PERIMOUNT BIOPROSTHESIS; MULTICENTER EXPERIENCE; RISK-FACTORS; IMPLANTATION; DEGENERATION; PLACEMENT; MISMATCH; POSITION; CRACKING;
D O I
10.1161/CIRCINTERVENTIONS.118.006453
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Percutaneous transcatheter pulmonary valve replacement (TPVR) has good clinical and hemodynamic outcomes in treating dysfunctional bioprosthetic valves (BPV) in the pulmonary position. Valve-in-valve therapy can further decrease the inner diameter (ID), potentially resulting in patient-prosthesis mismatch in patients with smaller BPVs. METHODS AND RESULTS: To evaluate feasibility and outcomes of intentional BPV fracture to enlarge the pulmonary valve orifice with TPVR, 37 patients from 13 centers who underwent TPVR with intended BPV fracture were evaluated. A control cohort (n=70) who underwent valve-in-valve TPVR without attempted fracture was evaluated. BPV was successfully fractured in 28 patients and stretched in 5 while fracture was unsuccessful in 4. A Melody valve was implanted in 25 patients with fractured/stretched frame and a Sapien (XT 3) valve in 8. Among patients whose BPV was fractured/stretched, the final ID was a median of 2 mm larger (0-6.5 mm) than the valve's true ID. The narrowest diameter after TPVR in controls was a median of 2 mm smaller (P<0.001) than true ID. Right ventricular outflow tract gradient decreased from median 40 to 8 mmHg in the fracture group. Cases with fracture/stretching were matched 1:1 (weight, true ID) to controls. Post-TPVR peak gradient was lower but not significant (8.35.2 versus 11.8 +/- 9.2 mmHg; P=0.070). There were no fracture-related adverse events. CONCLUSIONS: Preliminary experience shows intentional fracture of BPV frame can be useful for achieving larger ID and better hemodynamics after valve-in-valve TPVR.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Bioprosthetic Valve Fracture to Facilitate Valve-in-Valve Transcatheter Aortic Valve Replacement
    Sreedharan, Subhashaan
    Sellers, Stephanie L.
    Ihdayhid, Abdul Rahman
    Landes, Uri
    Blanke, Philipp
    Allen, Keith B.
    Chhatriwalla, Adnan K.
    Pibarot, Philippe
    Wood, David A.
    Webb, John G.
    Leipsic, Jonathon A.
    Sathananthan, Janarthanan
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2021, 5 (01): : 24 - 38
  • [2] Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement
    Chhatriwalla, Adnan K.
    Allen, Keith B.
    Saxon, John T.
    Cohen, David J.
    Aggarwal, Sanjeev
    Hart, Anthony J.
    Baron, Suzanne J.
    Dvir, Danny
    Borkon, A. Michael
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (07)
  • [3] Intentional bioprosthetic tricuspid valve fracture to facilitate transcatheter valve-in-valve deployment
    Karahalios, Brian
    Breinholt, John P.
    Little, Stephen H.
    Huie Lin, C.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2021, 97 (02) : 361 - 364
  • [4] When Device Failure Translates to Therapeutic Efficacy Intentional Fracture of Bioprosthetic Valve Rings as an Adjunctive Technique in Transcatheter Valve-in-Valve Replacement
    McElhinney, Doff B.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (07)
  • [5] Bioprosthetic Valve Fracture to Facilitate Transcatheter Valve-in-Valve Implantation
    Allen, Keith B.
    Chhatriwalla, Adnan K.
    Cohen, David J.
    Saxon, John T.
    Aggarwal, Sanjeev
    Hart, Anthony
    Baron, Suzanne
    Davis, J. Russell
    Pak, Alex F.
    Dvir, Danny
    Borkon, A. Michael
    ANNALS OF THORACIC SURGERY, 2017, 104 (05) : 1501 - 1508
  • [6] 1-Year Outcomes following Bioprosthetic Valve Fracture to Facilitate Valve-in-Valve Transcatheter Aortic Valve Replacement
    Chhatriwalla, Adnan K.
    Allen, Keith B.
    Saxon, John T.
    Cohen, David J.
    Nguyen, Tom C.
    Loyalka, Pranav
    Whisenant, Brian
    Yakubov, Steven J.
    Sanchez, Carlos
    Sathananthan, Janarthanan
    Stegman, Brian
    Harvey, James
    Garrett, H. Edward
    Tseng, Elaine
    Gerdisch, Marc
    Williams, Paul
    Kennedy, Kevin F.
    Webb, John
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2021, 5 (03): : 312 - 318
  • [7] Transcatheter Aortic Valve Replacement for Bioprosthetic Aortic Valve Failure The Valve-in-Valve Procedure
    Webb, John G.
    Dvir, Danny
    CIRCULATION, 2013, 127 (25) : 2542 - 2550
  • [8] Outcomes of valve-in-valve transcatheter aortic valve implantation with and without bioprosthetic valve fracture
    Brinkmann, Christina
    Abdel-Wahab, Mohamed
    Bedogni, Francesco
    Bhadra, Oliver Daniel
    Charbonnier, Gaetan
    Conradi, Lenard
    Hildick-Smith, David
    Kargoli, Faraj
    Latib, Azeem
    Van Mieghem, Nicolas M.
    Mylotte, Darren
    Landes, Uri
    Pilgrim, Thomas
    Stripling, Jan
    Taramasso, Maurizio
    Tchetche, Didier
    Testa, Luca
    Thiele, Holger
    Webb, John
    Windecker, Stephan
    Witt, Julian
    Wohlmuth, Peter
    Schofer, Joachim
    EUROINTERVENTION, 2021, 17 (10) : 848 - 855
  • [9] Efficacy and safety of transcatheter valve-in-valve replacement for Mitroflow bioprosthetic valve dysfunction
    Mosquera, Victor X.
    Gonzalez-Barbeito, Miguel
    Bouzas-Mosquera, Alberto
    Herrera-Norena, Jose M.
    Velasco, Carlos
    Salgado-Fernandez, Jorge
    Calvino-Santos, Ramon
    Vazquez-Gonzalez, Nicolas
    Vazquez-Rodriguez, Jose M.
    Cuenca-Castillo, Jose J.
    JOURNAL OF CARDIAC SURGERY, 2018, 33 (07) : 356 - 362
  • [10] Valve-in-Valve Transcatheter Aortic Valve Replacement and Bioprosthetic Valve Fracture Comparing Different Transcatheter Heart Valve Designs An Ex Vivo Bench Study
    Sathananthan, Janarthanan
    Sellers, Stephanie
    Barlow, Aaron M.
    Stanova, Viktoria
    Fraser, Rob
    Toggweiler, Stefan
    Allen, Keith B.
    Chhatriwalla, Adnan
    Murdoch, Dale J.
    Hensey, Mark
    Lau, Karen
    Alkhodair, Abdullah
    Dvir, Danny
    Asgar, Anita W.
    Cheung, Anson
    Blanke, Philipp
    Ye, Jian
    Rieu, Regis
    Pibarot, Phillippe
    Wood, David
    Leipsic, Jonathan
    Webb, John G.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (01) : 65 - 75