Calculated impact of higher-order monochromatic aberrations on retinal image quality in a population of human eyes

被引:57
作者
Guirao, A [1 ]
Porter, J
Williams, DR
Cox, IG
机构
[1] Univ Murcia, Dept Fis, Lab Opt, E-30071 Murcia, Spain
[2] Univ Rochester, Inst Opt, Rochester, NY 14627 USA
[3] Univ Rochester, Ctr Visual Sci, Rochester, NY 14627 USA
[4] Bausch & Lomb Inc, Rochester, NY 14692 USA
关键词
D O I
10.1364/JOSAA.19.000001
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We calculated the impact of higher-order aberrations on retinal image quality and the magnitude of the visual benefit expected from their correction in a large population of human eyes. Wave aberrations for both eyes of 109 normal subjects and 4 keratoconic patients were measured for 3-, 4-, and 5.7-mm pupils with a Shack-Hartmann sensor. Retinal image quality was estimated by means of the modulation transfer function (MTF) in white light. The visual benefit was calculated as the ratio of the MTF when the monochromatic higher-order aberrations are corrected to the MTF corresponding to the best correction of defocus and astigmatism. On average, the impact of the higher-order aberrations for a 5.7-mm pupil in normal eyes is similar to an equivalent defocus of similar to0.3 D. The average visual benefit for normal eyes at 16 c/deg is similar to2.5 for a 5.7-mm pupil and is negligible for small pupils (1.25 for a 3-mm pupil). The benefit varies greatly among eyes, with some normal eyes showing almost no benefit and others a benefit higher than 4 at 16 c/deg across a 5.7-mm pupil. The benefit for keratoconic eyes is much larger. The benefit at 16 c/deg is 12 and 3 for 5.7- and 3-mm pupils, respectively, averaged across four keratoconics. These theoretical benefits could be realized in normal viewing conditions but only under specific conditions. (C) 2002 Optical Society of America.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 51 条
[1]  
[Anonymous], BIOPHYSICS
[2]   Contributions of the cornea and the lens to the aberrations of the human eye [J].
Artal, P ;
Guirao, A .
OPTICS LETTERS, 1998, 23 (21) :1713-1715
[3]   ODD ABERRATIONS AND DOUBLE-PASS MEASUREMENTS OF RETINAL IMAGE QUALITY [J].
ARTAL, P ;
MARCOS, S ;
NAVARRO, R ;
WILLIAMS, DR .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1995, 12 (02) :195-201
[4]   EFFECTS OF AGING IN RETINAL IMAGE QUALITY [J].
ARTAL, P ;
FERRO, M ;
MIRANDA, I ;
NAVARRO, R .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1993, 10 (07) :1656-1662
[5]   RETRIEVAL OF WAVE-ABERRATION OF HUMAN EYES FROM ACTUAL POINT-SPREAD-FUNCTION DATA [J].
ARTAL, P ;
SANTAMARIA, J ;
BESCOS, J .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1988, 5 (08) :1201-1206
[6]   MONOCHROMATIC MODULATION TRANSFER-FUNCTION OF THE HUMAN EYE FOR DIFFERENT PUPIL DIAMETERS - AN ANALYTICAL EXPRESSION [J].
ARTAL, P ;
NAVARRO, R .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1994, 11 (01) :246-249
[7]  
ARTAL P, 1999, 1999 OSA ANN M SANT
[8]   Compensation of corneal aberrations by the internal optics in the human eye [J].
Artal, Pablo ;
Guirao, Antonio ;
Berrio, Esther ;
Williams, David R. .
JOURNAL OF VISION, 2001, 1 (01) :1-8
[9]  
Berny F., 1969, OPTICAL INSTRUMENTS, P375
[10]  
Berrio ME, 2000, INVEST OPHTH VIS SCI, V41, pS105