Miniaturized QCM-based flow system for immunosensor application in liquid

被引:44
作者
Michalzik, M [1 ]
Wilke, R [1 ]
Büttgenbach, S [1 ]
机构
[1] Tech Univ Braunschweig, Inst Microtechnol, D-3300 Braunschweig, Germany
关键词
thickness-shear-mode resonators; quartz crystal microbalance; PDMS; immunoassay;
D O I
10.1016/j.snb.2005.03.048
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report on a poly(dimethylsiloxane) (PDMS) microfluidic analysis system based on mass sensitive detection. It consists of a miniaturized quartz crystal microbalance (QCM) and a flow cell made out of PDMS which is bonded to the quartz substrate. Protein A was used for the immobilization and the functionality of this undercoating was tested by accumulation of anti-protein A. The sensor system was operated in a flow-through mode and the results were compared with measurements using an injection method, where a definite amount of solution is injected into a reservoir mounted on the QCM. The conducted measurements proved the excellent performance of the new flow system. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:410 / 415
页数:6
相关论文
共 15 条
[1]   NEW DESIGN FOR QCM SENSORS IN LIQUIDS [J].
AUGE, J ;
HAUPTMANN, P ;
HARTMANN, J ;
ROSLER, S ;
LUCKLUM, R .
SENSORS AND ACTUATORS B-CHEMICAL, 1995, 24 (1-3) :43-48
[2]  
BARBACAN S, 2000, BIOSENS BIOELECTRON, V15, P615
[3]  
BORNGRABER R, 2001, THESIS OTTO VON GUER
[4]  
Bovenizer JS, 1998, ANAL LETT, V31, P1287, DOI 10.1080/00032719808002866
[5]  
Büttgenbach S, 2001, P SOC PHOTO-OPT INS, V4205, P207, DOI 10.1117/12.417452
[6]   Poly(dimethylsiloxane) (PDMS) and silicon hybrid biochip for bacterial culture [J].
Chang, WJ ;
Akin, D ;
Sedlak, M ;
Ladisch, MR ;
Bashir, R .
BIOMEDICAL MICRODEVICES, 2003, 5 (04) :281-290
[7]   Three-dimensional micro-channel fabrication in polydimethylsiloxane (PDMS) elastomer [J].
Jo, BH ;
Van Lerberghe, LM ;
Motsegood, KM ;
Beebe, DJ .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2000, 9 (01) :76-81
[8]   OPERATION OF AN ULTRASENSITIVE 30-MHZ QUARTZ-CRYSTAL MICROBALANCE IN LIQUIDS [J].
LIN, ZX ;
YIP, CM ;
JOSEPH, IS ;
WARD, MD .
ANALYTICAL CHEMISTRY, 1993, 65 (11) :1546-1551
[9]   Development and application of a miniaturised quartz crystal microbalance (QCM) as immunosensor for bone morphogenetic protein-2 [J].
Michalzik, M ;
Wendler, J ;
Rabe, J ;
Büttgenbach, S ;
Bilitewski, UB .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 105 (02) :508-515
[10]   Design, manufacturing, and characterization of high-frequency thickness-smear mode resonators [J].
Rabe, J ;
Büttgenbach, S ;
Zimmermann, B ;
Hauptmann, P .
PROCEEDINGS OF THE 2000 IEEE/EIA INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM & EXHIBITION, 2000, :106-112